Penentuan Jadwal Perawatan Mesin Pompa melalui Analisis Keandalan pada PDAM Gunung Lipan, Samarinda Seberang, Kalimantan Timur Fathiruddin Ilwan; Fatkhul Hani Rumawan; Lina Dianati Fathimahhayati
Dinamika : Jurnal Ilmiah Teknik Mesin Vol 8, No 1 (2016)
Publisher : Jurusan Teknik Mesin, Universitas Halu Oleo

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (509.107 KB) | DOI: 10.33772/djitm.v8i1.1726

Abstract

PDAM Gunung Lipan Samarinda Seberang adalah perusahaan yang menyediakan pasokan air minum di Samarinda. Salah satu bagian yang penting dalam proses produksi air adalah mesin pompa. Jenis mesin pompa yang digunakan dalam PDAM Gunung Lipan Samarinda Seberang adalah Grundfos I, Grundfos II, dan Grundfos III. Semakin sering mesin pompa digunakan, maka akan dapat menurunkan kinerja pompa. Berdasarkan permasalahan tersebut, maka perlu dilakukan penelitian tentang penentuan jadwal pemeliharaan untuk mesin pompa. Penelitian ini dimulai dengan menghitung Time To Failure (TTF) dan Time To Repair (TTR) pada setiap mesin. Tahap selanjutnya adalah menghitung keandalan setiap mesin dengan mempertimbangkan distribusi probabilitas kegagalan mesin. Tahap terakhir adalah menentukan jadwal pemeliharaan di setiap mesin pompa berdasarkan perhitungan Mean Time Between Failure (MTBF) dan Mean Time To Repair (MTTR). Hasil penelitian menunjukkan bahwa keandalan Grundfos I adalah 0.705 di hari ke-16 dari operasi,  keandalan Grundfos II adalah 0.700 di hari ke-24 dari operasi, dan  keandalan Grundfos III adalah 0.703 di hari ke-19 dari operasi. Jadwal pemeliharaan untuk mesin Grundfos I adalah maksimum setiap 45 hari dengan waktu perbaikan maksimum 2.834 jam, jadwal pemeliharaan untuk mesin Grundfos II adalah maksimum setiap 47 hari dengan waktu perbaikan maksimum 1.001 jam, sementara jadwal pemeliharaan untuk mesin Grundfos III maksimum setiap 53 hari dengan waktu perbaikan maksimum 6.203 jam.
A CHARACTERISTICS OF LINEARITY AND SENSITIVITY IN MEASURING THE MQ-4 SENSOR ON GAS LINE LEAKAGE Arif Harjanto; Fatkhul Hani Rumawan; Didit Suprihanto; Haviluddin Haviluddin; Bangkit Bekti Nurdianto
Jurnal Teknik Informatika (Jutif) Vol. 3 No. 2 (2022): JUTIF Volume 3, Number 2, April 2022
Publisher : Informatika, Universitas Jenderal Soedirman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.jutif.2022.3.2.229

Abstract

A natural gas utilization with a domestic house-gas pipeline is essential. However, the house-gas installation pipe can cause a dangerous leak, so the house-gas leak detector is requires. This study aims to build and analyze a leak detector for natural gas flow on the stove using the MQ-4 gas sensor based on the house-gas linearity and sensitivity characteristics levels in the air with a threshold of 1000 ppm. Based on experimental, the sensor linearity value for the detected house-gas has been obtained in a correlation coefficient of 0.99 which indicates the sensor is quite sensitive in order to the house-gas detected. Then, the sensor sensitivity value has been acquired with the regression equation Y=-0.00449+(0.000481)X which means the voltage value at 0 ppm is around -0.00449 volts and increase at each ppm are 0.000481 volts with a value of 0.000481 volts with the effectiveness of the tools reaches 100%. Therefore, the study shown that the detection tools and systems can work properly.
APLIKASI PHOTOVOLTAIC CELL (PV) TERHADAP VARIASI BEBAN ELEKTRIK SEBAGAI ENERGI ALTERNATIF Nur Rani Alham; Fatkhul Hani Rumawan; Muslimin Muslimin; Restu Mukti Utomo; Ahmad Maulana
Jurnal Teknik Elektro Uniba (JTE UNIBA) Vol. 5 No. 2 (2021): JTE UNIBA (Jurnal Teknik Elektro Uniba)
Publisher : Lembaga Penelitian Universitas Balikpapan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/jteuniba.v5i2.92

Abstract

Teknologi saat ini sudah semakin canggih dan banyak digunakan. Penggunaan teknologi ini menyebabkan peningkatan konsumsi daya listrik yang semakin besar, sedangkan sumber listrik yang digunakan masih menggunakan energi tidak terbarukan. Panel surya atau Photovoltaic adalah salah satu Energi Baru Terbarukan (EBT) yang sumber energinya berasal dari matahari. Sumber energi ini sangat familiar dimasyarakat Indonesia, tetapi masih sangat sedikit pemanfaatannya. Oleh karena itu dilakukan pengaplikasian Photovoltaic Cell (PV) terhadap variasi beban elektrik sebagai energi alternatif. Pada penelitian ini menggunakan Photovoltaic Cell berkapasitas 150 Wp, dengan jenis Polycrystaline silicon, baterai 12V/38Ah, inverter, dan solar charge control. Penelitian dilakukan selama 3 hari berturut-turut, ketika cuaca dalam keadaan cerah. Pengambilan data arus dan tegangan dilakukan selama 4 jam dengan menggunakan beban lampu 15W, dan 15W+60W. Dari hasil penelitian didapatkan modul Photovoltaic pada pabrik diketahui efisiensi sebesar dan pada penggunaan PV yang telah diukur pada penelitian didapat efisiensi daya guna sebesar penggunaan pada saat charge. Efisiensi daya inverter pada hari ke-1 sebesar 64%, hari ke-2 sebesar 59%, dan hari ke-3 sebesar 55%.