Penerapan Metode Jala Sudut Proteksi dan Bola Bergulir Pada Sistem Proteksi Petir Eksternal yang Diaplikasikan pada Gedung W Universitas Kristen Petra Hosea, Emmy; Iskanto, Edy; M. Luden, Harnyatris
Jurnal Teknik Elektro Vol 4, No 1 (2004): MARET 2004
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (244.179 KB) | DOI: 10.9744/jte.4.1.

Abstract

Lightning protection system consist of external protection, grounding system and internal protection. Three methods to determine air termination are mesh size method, protective angle method and rolling sphere method. This paper describes the application of those methods on W building Petra Christian University. The result show that the building needs more lightning protection system based on rolling sphere method analysis. Abstract in Bahasa Indonesia : Sistem proteksi petir terdiri dari proteksi eksternal, sistem pembumian dan proteksi internal. Penentuan terminasi udara menggunakan tiga metode yaitu metode jala, sudut proteksi dan bola bergulir. Makalah ini menjelaskan tentang aplikasi ketiga metode tersebut pada gedung W UK Petra. Hasil yang diperoleh menunjukkan bahwa gedung W Universitas Kristen Petra membutuhkan tambahan sistem proteksi petir berdasarkan analisis dengan metode bola bergulir. Kata kunci : Sistem proteksi petir.