Model Based Controller With Internal Model Control (IMC) Which Tunning By Set Point and Disturbance on Power Plant Based HYSYS Hendrik Elvian Gayuh Prasetya; Totok R. Biyanto
IPTEK Journal of Proceedings Series No 1 (2015): 1st International Seminar on Science and Technology (ISST) 2015
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (60.334 KB) | DOI: 10.12962/j23546026.y2015i1.1030

Abstract

Waste heat recovery generation (WHRG) is a power plant systems which utilize waste gas in process of industrie. To design plant of WHRG need right control parameters for maintain heat and mass balance. The control technique of PID is the methode usually used in all industrie by doing tunning based of changes set point changes. In fact, not only based on the change of set point tunning can generate proper response, but the value based on disturbance change of tunning is also appropriate for used. This is due to value based on tunning disturbance can reduce the nuisance value of direct entry at the output of the process. The tunning of the set point value is given i.e. ± 5%, ± 10% and ± 15% of the design data are used, whereas for tunning of disturbance value that is used i.e., ± 5% of the value of the input parameter used as a disturbance. Based on the resulting control response indicates that the method for use to control the tunning disturbance in this research, it is not appropriate to be applied using methods of IMC-PID. This is due to the characteristics of the resulting response indicates a value that is less good.
Economical Aspect of Heat Exchanger Cleaning Affected by Fouling Mades Darul Khairansyah; Totok R. Biyanto
IPTEK Journal of Proceedings Series No 1 (2015): 1st International Seminar on Science and Technology (ISST) 2015
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (29.326 KB) | DOI: 10.12962/j23546026.y2015i1.1022

Abstract

Fouling is the accumulation of foulant in a heat exchanger. Fouling increases the pressure drop and energy loss. Losses due to fouling in the distillation unit for crude oil reached US $ 4.2-10 billion per year in the United State. Fouling couldn’t be avoided, but it could be mitigation. One of the mitigation method is periodic cleaning of the heat exchanger. The time interval of a heat exchanger cleaning schedule is 1-36 months. Energy recovery, additional costs due to the performance of the pump and the cleaning cost are used as variables to determine saving. Results from this research showed that the heat exchanger is cleaned at 9 month is optimal cleaning schedule. Heat exchanger has savings about IDR 7.9 billion at 9 month. The amount is derived from the energy recovery about IDR 8.8 billion, reduced by a cleaning cost about IDR 0.2 billion and the advantage due to additional pumping cost about IDR 1.1 billion.