ANALISIS UNSUR MINOR KATION DALAM SAMPEL AIR ALAM DENGAN MENGGUNAKAN TEKNIK KROMATOGRAFI ION Muhammad Amin
TECHNO: JURNAL PENELITIAN Vol 5, No 1 (2016): Techno Jurnal Penelitian
Publisher : Universitas Khairun

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33387/tk.v5i1.780

Abstract

Tulisan ini berkaitan dengan studi banding mengenai kualitas air alam yang diperoleh dari berbagai lokasi di Ternate, Maluku Utara. Empat jenis air seperti air sungai, air sumur, air danau, dan air PDAM dievaluasi. Pada penelitian ini, teknik kromatografi ion digunakan sebagai metode analisis untuk menentukan kation anorganik (litium, natrium, amonium, kalium, kalsium, dan magnesium) yang terkandung dalam berbagai jenis air alam. Kombinasi Metrosep C2-150 sebagai kolom analitik dengan campuran eluen 4mM asam tartarat dan 0,75 mM asam dipikolinik digunakan dalam percobaan ini. Kata Kunci: Kromatografi ion, air alam, kation anorganik
Penentuan Secara Serempak Kadar Minor Anion (F-, Cl-, NO2-, Br-, NO3-, SO42– dan PO43-) dalam Sampel Air Botol Kemasan dengan Teknik Kromatografi Ion Kinerja Tinggi Muhammad Amin
TECHNO: JURNAL PENELITIAN Vol 9, No 1 (2020): Techno Jurnal Penelitian
Publisher : Universitas Khairun

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33387/tjp.v9i1.1744

Abstract

Analytical and separation conditions for the simultaneous determination of minor anions (F-, Cl-, NO2-, Br-, NO3-, SO42–, and PO43-) using ion chromatography technique have been optimized. In this study, ion chromatography with a suppressed conductivity detection system was applied to determine the ionic species with high sensitivity. By these conditions, it has been targeted in the determination of the seven anions in bottled drinking water samples. With concentration of 6 mM Na2CO3 and 1,2 mM NaHCO3were used as the eluent combination for all determinations. All the above anions could be completely determied and eluted were less than 30 min. All anions were displayed symmetrical peak shapes as in the chromatograms. The correlation coefficient (r) varies between 0.9995 and 1 for the above seven anions, whereas the detection limits calculated at S/N= 3 were 0.02–0.45 µg/L. The obtained optimum conditions were then applied to the simultaneous determination of minor anions in 6 bottled drinking water samples with different brands. From the overall drinking water samples which was collected commersially in North Maluku, there were no minor anions concentration exceeding the specified quality standards.