Suharyanto Suharyanto
Department of Electrical and Information Engineering, Faculty of Engineering, Universitas Gadjah Mada

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Single Phase Full Bridge Inverter Control as Reactive Power Compensator Anang Budhi Nugroho; Eka Firmansyah; Suharyanto Suharyanto
IJITEE (International Journal of Information Technology and Electrical Engineering) Vol 1, No 4 (2017): December 2017
Publisher : Department of Electrical Engineering and Information Technology,Faculty of Engineering UGM

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1259.541 KB) | DOI: 10.22146/ijitee.35539

Abstract

The drop of local load voltage on the distribution system is an indicator that the system experiences reactive power shortage. It can be overcome by an inverter controlled to compensate reactive power. The benefit of the inverter is that it is easily configured with a variety of functions. This paper presents the control configuration of inverter as reactive power compensators. The method used is a current control system of the proportional integrator (PI) – dq based transformation. This method generates reactive power by regulating the current domain (Id, ref = 0), while the current domain (Iq,ref) is set according to the need. Phase locked loop (PLL) is added so that the inverter can be synchronized well with the grid. According to the analysis of the PI current control, the local load voltage is stable at 219.88 Vrms and the reactive power generated by the inverter is 298 VAR with steady state error 0.11% of the reference power without oscillation.