Claim Missing Document
Check
Articles

Found 3 Documents
Search

Rancang Bangun Sistem Monitoring Suhu dan Pakan Pada Kandang Ayam Berbasis Internet Of Things mengunakan NODEMCU ESP8266 Shofi Syarifudin; Rizky Mubarok; Edmud Ucok Armin
Journal of Electronic and Electrical Power Applications Vol 1 No 2 (2021): JEEPA Volume 1 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (904.808 KB)

Abstract

The development of technology in Indonesia is increasingly advanced along with the times. With the industrial era 4.0, it is easier for every job that humans do. Now more and more industries are using robots as a substitute for human labor. With the development of the times that have an impact on technological change and the creation of internet of things (IOT) technology which makes it easier for humans to do a job. In this study, the NODEMCU ESP8266 microcontroller was used as the implementation of controlling temperature, humidity and feed based on the internet of things (IOT). The data taken from these sensors can be accessed in real time on the web and Telegram bot via smartphone connected to the internet.
Analisis Sistem Grounding Menggunakan Elektroda Ground Rod Jenis Tembaga Pada Gedung A dan D di Universitas Peradaban Rizky Mubarok; Rizki Noor Prasetyono; Zidan Alfarikhi
Journal of Telecommunication, Electronics, and Control Engineering (JTECE) Vol 4 No 2 (2022): Journal of Telecommunication, Electronics, and Control Engineering (JTECE)
Publisher : LPPM Institut Teknologi Telkom Purwokerto

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20895/jtece.v4i2.708

Abstract

Penelitian ini dilakukan untuk menganalisa kelayakan nilai pentanahan pada gedung A dan gedung D di Universitas Peradaban menggunakan elektroda ground rod jenis tembaga. Nilai pentanahan yang sesuai dengan standar PUIL 2011 yaitu 0 sampai dengan 5 Ω. Faktor yang dapat mempengaruhi nilai tahanan pentanahan yaitu variabel kedalaman elektroda, jenis tahanan tanah, diameter elekroda, jumlah elektroda dan jenis tanah. Pada penelitian ini dilakukan pengukuran dengan menggunakan alat earth tester dengan merek kyoritsu dengan metode tiga titik. Berdasarkan hasil pengukuran yang didapat untuk nilai rata-rata tahanan pentanahan gedung A yaitu 0.518 Ω dan untuk nilai rata-rata tahanan pentanahan gedung D yaitu 0.804 Ω. Keduan bangunan itu sudah memiliki nilai tahanan pentanahan sesuai dengan PUIL 2011. Dari hasil analisis dapat disimpulkan bahwa untuk mendapatkan nilai tahanan pentanahan ≤ 1 Ω dengan jenis tanah rawa yaitu 10 Ω-meter maka dibutuhkan kedalaman 12 meter.
Pengaruh Penambahan Kapasitor Bank terhadap Perbaikan Daya pada Direct On Line (DOL) Berbasis Programmable Logic Controller (PLC) di Motor Listrik 3 Phase Rizki Noor Prasetyono; Rizky Mubarok; Rito Cipta Sigitta; Muhammad Zidan Alfarikhi; Nasrulloh Nasrulloh; Randi Adzin Murdiantoro
Journal of Telecommunication Electronics and Control Engineering (JTECE) Vol 5 No 2 (2023): Journal of Telecommunication, Electronics, and Control Engineering (JTECE)
Publisher : LPPM INSTITUT TEKNOLOGI TELKOM PURWOKERTO

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20895/jtece.v5i2.1066

Abstract

Tujuan penelitian ini mengetahui pengaruh penambahan kapasitor bank terhadap Perbaikan Daya pada Direct On Line (DOL) berbasis Programmable Logic Controller (PLC) di Motor Listrik 3 Phase. Mayoritas beban di industri memakai beban motor induksi 3 phase yang merupakan beban induktif. Keuntungan motor listrik 3 phase tersebut dan negara yang masih menyubsidi konsumsi listrik. Hal ini merupakan suatu indikasi setiap konsumen dapat melakukan perbaikan faktor daya dengan tujuan efisiensi daya. Penelitian yang digunakan adalah jenis kuantitatif dengan mengeksperimenkan penambahan kapasitor bank pada motor 3 phase. Melalui tahapan perancangan alat, pengujian alat pengambilan data faktor daya & efisiensi, analisis data dan penarikan kesimpulan. Hasil penelitian penggunaan kapasitor bank berpengaruh pada perbaikan faktor daya yang ditunjukkan dari signifikasni 0,001 < 0,05 pada rangkaian DOL di motor listrik 3 fasa berbasis PLC. Diperkuat dengan nilai rata-rata cos phi sesudah penggunaan kapasitor bank memiliki nilai 0,912 yang artinya sudah sesuai standar PLN yaitu nilai 0,9. Cos phi mendekati angka 1 dapat dikatakan penggunaan listrik lebih efisien. Dapat dilihat dari nilai rata-rata efisiensi sebelum dan sesudah yaitu 68,29% menjadi 91,17% artinya mengalami peningkatan.