Model of The Distance Between The Readability of Word Messages on Conventional Signs and Electronic Signs Budiati, Anik
Ranah Research : Journal of Multidisciplinary Research and Development Vol. 6 No. 5 (2024): Ranah Research : Journal Of Multidisciplinary Research and Development (Juli 20
Publisher : Dinasti Research

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/rrj.v6i5.1083

Abstract

Traffic signs are divided into conventional signs and electronic signs. The message conveyed is in the form of a pigtogram and/or electronic message. (Budiati, 2014) compared the legibility distance of letter dimensions on conventional signs, it was found that H=1.032+0.273D with H being the height of the letter and D being the reading distance. (Budiati, 2023), examined the relationship between the driver's reading speed and the number of words and lines in the Variable Message Sigh. This research produces a reading speed of 1.37 words/second. The research was continued to obtain a modeling of the readability distance for conventional and electronic word message signs with the dependent variable (Y) reading distance. Data on reading distance and reading time in the field were analyzed using the SPSS v.23 approach, and the obtained was Y= 2.990 (X1) + 0.009(X2) + 0.001(X3) for conventional signs Y = 3.557 (X1) + 0.440 (X2) + 0.004 (X3), while Based on collineatity the modeling value of reading distance (2) versus reading distance 1 is as follows: Y = 5.463 + 0.513 (X1) + 0.10 (X2) + 0.009 (X3) + 0.004.
Design of E.R. Building At Ct Arsa Palu Hospital With Liquefaction Potential Ghozi, Mohammad; Yulianto, Achmad; Budiati, Anik
Ranah Research : Journal of Multidisciplinary Research and Development Vol. 6 No. 5 (2024): Ranah Research : Journal Of Multidisciplinary Research and Development (Juli 20
Publisher : Dinasti Research

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/rrj.v6i5.1084

Abstract

This design hospital building is planned to be built in the city of Palu. Palu City has high earthquake potential, has history of liquefaction, tsunami and landslides disasters. Thorough design is needed so that this hospital building still become a place for health services after a disaster occurs. The building was designed using the Special Moment Resisting Frame Structure system based on the SNI. Earthquake load analysis uses the response spectrum method based on Earthquake Resistance Planning Procedures (SNI 1726:2019). This concept obtains structure design that meets SNI and still strong in strong earthquake and liquefaction. Analysis has been carried out and it was found that the potential for liquefaction to occur at a depth of 1.5 M to 4.5 M so that the foundation chosen was 4 piles with a diameter of 40 cm, a depth of 6 meters per pile cap. From the results of calculations, it shows that the structure of the emergency room building at CT Arsa Palu Hospital is safe from an analytical perspective.