p-Index From 2019 - 2024
0.444
P-Index
This Author published in this journals
All Journal Mestro
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Mestro

Comparative Analysis of the Performance of Ice Cream Making Machines Using Variations in Capillary Pipe Diameters Ferry Sugara; Waluyo Djoko Yudisworo; Karsid Karsid
Mestro Vol 3 No 02 (2021): Edisi Desember
Publisher : Fakultas Teknik Universitas 17 Agustus 1945 Cirebon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47685/mestro.v3i02.369

Abstract

Current refigeration technology has an important influence in improving the quality of food products. The purpose of this study is to find out how much the difference in performance generated from the expansion device in the form of two capillary pipes of different diameters and know the power consumption of electricity used, so that it knows the electric power per day. The method used in this study is to test the ice cream maker refrigeration system, by testing its performance by measuring the temperature and pressure in each main component when the system is steady. The results of the actual COP value of the average capillary pipe diameter of 0.028 inches are 2.16 while the actual COP value of the average capillary pipe diameter of 0.031 inches is 2.74. And the actual COP value of a 0.028 inch diameter capillary tube has a greater value of 2.16 while a capillary pipe with a diameter of 0.031 inches has a smaller value of 1.88. Whereas the biggest value of refractive efficiency at the average value is a capillary pipe with a diameter of 0.028 inches of 63.58%. While for capillary pipes with a diameter of 0.031 inches smaller the value of refraction efficiency averaged 59.49% and the cabin temperature in capillary pipes with a diameter of 0.028 inches, the average value was -9.82 0C. While for capillary pipes with a diameter of 0.031 inches smaller it has a cooler average value of -9.09 0C.
Performance Testing of Centrifugal Pump Type with 3 Hp Power Wasiran Wasiran; Waluyo Djoko Yudisworo; Endang Prihastuty
Mestro Vol 4 No 02 (2022): Edisi Desember
Publisher : Fakultas Teknik Universitas 17 Agustus 1945 Cirebon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47685/mestro.v5i02.365

Abstract

Pumps are fluid machines whose uses are very broad and important, ranging from industry to household needs. Selection of pump performance characteristics is very important and must be adjusted to the needs which include: discharge, head, power, and rotation. The performance characteristics of the pump are obtained through testing. In connection with the importance of information about pump performance characteristics, through this research activity efforts will be made to test centrifugal pumps using 3 hp of power. In this research, the data obtained from the direct test results will be entered, where the test is carried out at the Machine Performance Test Laboratory. In this test, the pump pressure data obtained from the gauge gradually with several valve openings, then the data is entered into the data table that has been prepared. The test was carried out to test the ability of the centrifugal pump test equipment using 3 HP power which was prepared as one of the laboratory pump test equipment for engine performance testing. In testing the centrifugal pump there are 3 variables that will be used to carry out the test, namely the first by using a tachometer which is useful for measuring shaft rotation, the second by using a Bordoun manometer which is useful for measuring fluid pressure, the third by using an orifice which functions to measure speed fluid.