Analysis of Determining the Surge Arrester Protective Distance for Protection on 60 MVA Power Transformers at the 150 KV Main Substation in Surabaya Barat Widagdo, Reza Sarwo; Budiono, Gatut; Nasichin, Miftachun
Jurnal Riset Rekayasa Elektro Vol 6, No 1 (2024): JRRE VOL 6 NO 1 JUNI 2024
Publisher : PROGRAM STUDI TEKNIK ELEKTRO

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/jrre.v6i1.21555

Abstract

Because it provides electrical energy to customers that require protection from lightning interference, the substation is a crucial location. An electrical equipment's defense against lightning strikes is provided by a lighting arrestor. The arrester should be placed as near to the transformer as feasible for optimal protection. In order to restrict the installation of arresters to safeguard equipment, the maximum distance for arrester installation must be established. This study only looks at one 60 MVA transformer in the Surabaya Barat Main Substation, and its goal is to determine the minimum amount of error in transformer protection. Based on the maximum possible surge arrester surge arrester jarak with a power transformer at the Surabaya Barat Main Substation, the maximum possible surge arrester distance is 8,135 meters. Based on surge arrester capability, the transformer may be protected from over voltage since the maximum voltage that can occur is just 150.83 kV, with the maximum voltage remaining below the transverse impulse drop of around 650 kV.
Prediction of Age Loss on 160 KVA Transformer PT. PLN ULP Kenjeran Surabaya using The Linear Regression Method Widagdo, Reza Sarwo; Andriawan, Aris Heri
Jurnal Riset Rekayasa Elektro Vol 5, No 2 (2023): JRRE VOL 5 NO 2 DESEMBER 2023
Publisher : PROGRAM STUDI TEKNIK ELEKTRO

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/jrre.v5i2.18140

Abstract

Distribution transformer is one of the important equipment in the distribution of electricity to consumers. The electricity demand increases every year, so that the transformer works optimally, it must also be considered regarding the loading. According to IEC 354 if the transformer is loaded stable 80% with conditions around 20℃ and the winding temperature is 98℃, but if the ambient temperature is more than 20℃ then the age of the transformer will decrease. With an average loading of 71.75%, based on the calculation that the predicted useful age of the 160 KVA distribution transformer in 2027 will have an age loss index of 1.1 p.u, so it is estimated that the remaining age of the distribution transformer is 12 years and 7 months. Analysis using a statistical approach assisted by SPSS software was also carried out to see how much influence the loading has on the age loss of the transformer.