ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
Vol 8, No 2 (2020): ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektro

Energy Saving Building Strategies through The Application of Solar Control Glass

NUR LAELA LATIFAH (Department of Architecture, Institut Teknologi Nasional Bandung, Indonesia)
ERWIN YUNIAR RAHADIAN (Department of Architecture, Institut Teknologi Nasional Bandung, Indonesia)



Article Info

Publish Date
19 May 2020

Abstract

ABSTRAKSesuai dengan konsep Green Building, desain bangunan harus memperhatikan penghematan energi operasional bangunan. Semakin besar beban termal, maka semakin boros konsumsi energi listrik. Salah satu cara untuk menurunkan energi listrik adalah dengan mengurangi beban termal eksternal, sehingga pemilihan jenis solar control glass merupakan aspek yang sangat penting. Metoda analisis dilakukan secara kuantitatif. Sebagai kasus studi yaitu Gedung Kantor Pengelola Bendungan Sei Gong di Batam, dan berdasarkan perhitungan Calculator OTTV akan ditentukan alternatif solar control glass yang tepat agar memenuhi syarat dengan batas maksimal OTTV di Indonesia (45 Watt per meter persegi). Manfaat penelitian ini adalah memperoleh masukan pemilihan tipe kaca yang tepat berdasarkan SHGC, pada kasus bangunan kantor.Kata kunci: Hemat energi operasional bangunan, Overall Thermal Transfer Value, Solar Control Glass, Solar Heat Gain Coefficient ABSTRACTIn accordance with the Green Building concept, building designs must pay attention to building operational energy savings. The greater the thermal load, the more wasteful the electricity consumption of the AC system. One way to reduce AC loads is to reduce external thermal loads, then choosing the type of solar control glass is a very important aspect. The method of analysis is done quantitatively. As a case study is Sei Gong Dam Management Office Building in Batam, and based on OTTV Calculator calculation an appropriate solar control glass alternative will be determined to meet the requirements with the maximum OTTV limit in Indonesia (45 Watt per square meter). The benefit of this research is to get input on selection of the right type of glass based on SHGC, in the case of office buildings.Keywords: Energy saving on building operation, Overall Thermal Transfer Value, solar control glass, Solar Heat Gain Coefficient

Copyrights © 2020






Journal Info

Abbrev

elkomika

Publisher

Subject

Electrical & Electronics Engineering Engineering

Description

Jurnal ELKOMIKA diterbitkan 3 (tiga) kali dalam satu tahun pada bulan Januari, Mei dan September. Jurnal ini berisi tulisan yang diangkat dari hasil penelitian dan kajian analisis di bidang ilmu pengetahuan dan teknologi, khususnya pada Teknik Energi Elektrik, Teknik Telekomunikasi, dan Teknik ...