eProceedings of Engineering
Vol 6, No 2 (2019): Agustus 2019

Evaluasi Kinerja Alat Penukar Kalor Spiral Tube In Shell Pada Parallel Flow Dan Counter Flow

Rifqi Firdaus (Telkom University)
Tri Ayodha Ajiwiguna (Telkom University)
M. Ramdlan Kirom (Telkom University)



Article Info

Publish Date
01 Aug 2019

Abstract

AbstrakAlat penukar kalor ( heat exchanger ) adalah suatu perangkat dimana dua aliran fluida dengan suhuyang berbeda bergerak bertukar kalor. Penukar kalor mempunyai tipe dan desain yang berbeda, salah satujenisnya yaitu penukar kalor spiral tube in shell. Umumnya pada penukar kalor tipe spiral tube in shellterdapat dua jenis aliran yaitu parallel dan counter flow. Penelitian ini dilakukan untuk mengevaluasikinerja penukar kalor spiral tube in shell pada dua arah aliran yang berbeda. Dengan menggunakan jenisfluida yang sama yaitu air dan laju aliran massa yang sama di kedua sisi yaitu sebesar 0.017 kg/s makakinerja alat penukar kalor dapat dievaluasi melalui nilai U dan nilai effectiveness (𝜀). Rentang pengambilandata yaitu dari suhu hot fluid inlet sebesar 50 – 80 oC, pengambilan data dilakukan dengan mencatat seluruhinformasi suhu pada thermocouple display saat suhu hot fluid inlet menunjukkan kenaikan ±5C darirentang minimum. Berdasarkan eksperimen yang dilakukan nilai U pada arah aliran parallel flowmenghasilkan nilai sebesar 0.5462 kW/m2.K sedangkan pada counter flow menghasilkan nilai 1.4200 %lebih tinggi yaitu 0.5604 kW/m2.K. Untuk arah aliran parallel flow menghasilkan effectiveness 36.9815 %sedangkan arah counter flow menghasilkan effectiveness 5.0415 % lebih tinggi yaitu 42.0229 % Kata kunci : efektivitas, koefisien perpindahan kalor, parallel flow, counter flow Abstract Heat exchanger is a device where two fluid flows with different temperatures move to exchange heat.Heat exchangers have different types and designs, one of which is a spiral tube in shell heat exchanger.Generally in spiral tube in shell heat exchanger there are two types of flow, namely parallel and counterflow. This study was conducted to evaluate the performance of spiral tube in shell heat exchangers in twodifferent flow directions. By using the same type of fluid, namely water and the same mass flow rate on bothsides, which is equal to 0.017 kg / s, the performance of heat exchanger can be evaluated through U valueand effectiveness value (ε). Data retrieval range is from the hot fluid inlet temperature of 50 - 80 C, datacollection is done by recording all temperature information on the thermocouple display when the hot fluidinlet temperature shows an increase of ± 5 oC from the minimum range. Based on experiments carried outthe U value in the direction of parallel flow produces a value of 0.5462 kW/m2.K while the counter flowproduces a value of 1.4200 % higher that is 0.5604 kW/m2.K. For parallel flow direction, it produceseffectiveness of 36.9815% while the counter flow direction results in effectiveness 5.0415% higher, that is42.0229%.Key word : effectiveness, heat transfer coefficient, parallel flow, counter flow

Copyrights © 2019






Journal Info

Abbrev

engineering

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Engineering Industrial & Manufacturing Engineering

Description

Merupakan media publikasi karya ilmiah lulusan Universitas Telkom yang berisi tentang kajian teknik. Karya Tulis ilmiah yang diunggah akan melalui prosedur pemeriksaan (reviewer) dan approval pembimbing ...