cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota semarang,
Jawa tengah
INDONESIA
BERKALA FISIKA
Published by Universitas Diponegoro
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
BERKALA FISIKA adalah jurnal saintifik yang diterbitkan secara periodik 3 bulanan. Jurnal ini memuat kajian-kajian Fisika baik kajian teoretik maupun hasil eksperimen. Jurnal ini juga memberi ruang yang luas bagi kajian – kajian aplikasi fisika dalam bidang teknologi, ilmu-ilmu hayati dan kedokteran.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 23, No 1 (2020): Berkala Fisika" : 6 Documents clear
UJI KESESUAIAN STANDAR NILAI HVL FILTER ALUMINIUM PADA PESAWAT SINAR-X MAMMOGRAFI: STUDI KASUS DI RUANG INSTALASI RADIOLOGI RS. SILOAM MAKASSAR Mutmainna, Azri; Astuty, Sri Dewi; Dewang, Syamsir; Mulyadin, Mulyadin
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (288.688 KB)

Abstract

The quality control of X-ray radiation in a radiology device plays an important role in determining the clinical use feasibility. The HVL value test of a filter is very important because it determines the effective of X-ray energy. HVL values indicate the thickness of the absorbent material to absorb X-ray intensity up to half of its original intensity. This research is devoted to testing the feasibility of Mammography equipment in the radiology installation room of Siloam Makassar hospital by comparing two methods of determinations the HVL value in the variation of voltage 23, 25, 27, 29, 31 and 33 kVp. The HVL value that determined from direct methods without filters is used as a base value that to be compared with the HVL value which determined by indirect methods through calculations after the addition of aluminum filter thicks to gradually. HVL values by indirect measurements ranged from 0.268−0.401 mmAl, while by direct measurements between 0.291−0.338 mmAl with a deviation between 1.39−7.90%. The results obtained indicate that the HVL value for all X-ray tube voltage variations from the two methods in use still on ranges the tolerance standard so that it can be reported that the X-ray mammography at the Siloam hospital was declared feasible.
PENGEMBANGAN KARAKTERISTIK OPTIS PADA LARUTAN PERAK KOLOID MENGGUNAKAN METODE ELEKTRO-OPTIS Tiwiyaningsih, Tiwiyaningsih; Rahmawati, Aidah; Nurhasanah, Wahidatun Dewi; Richardina, Very; Khumaeni, Ali; Firdausi, Ketut Sofjan; Sugito, Heri; Soesanto, Qidir Maulana Binu; Azam, Much
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (244.635 KB)

Abstract

In this paper we present a new development of optical properties on colloidal silver solutions using electro-optics effect. Samples of silver nanoparticles (NPP) were obtained by ablation method and then diluted in water to obtain various concentrations. To obtain optical characteristics of colloidal silver solutions through the electro-optical effect, the changes in the polarization of light was measured as the sample was applied by high external potential difference. The light source used was laser pointer with  = 650 nm. The results show that the colloidal silver solution shows non-linear active optical properties with increasing concentration and at a concentration of 4.6 ppm maximum natural polarization occurs. In the case of electro-optics, a voltage increase results in electro-optical contributions which correspond to the effects of non-linear polarization due to high electric fields. However, at 8 kV the maximum polarization appears also at a concentration of 4.6 ppm, which is the same as the natural polarization at that concentration. The study of colloidal silver solutions is very interesting to be further developed by electro-optical methods, because challenges and unanswered phenomena can contribute or alternative perspectives in understanding the interaction of light with matter, especially colloidal silver solutions, and the like.
TIPE MANUSKRIP PADA JURNAL BERKALA FISIKA Anam, Choirul
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (87.788 KB)

Abstract

TIPE MANUSKRIP PADA JURNAL BERKALA FISIKA
RANCANG BANGUN SISTEM KEAMANAN PINTAR PADA PINTU KAMAR MENGGUNAKAN RFID, PASSWORD DAN ANDROID BERBASIS ARDUINO UNO Setyawan, Agus; Prabowo, Muhammad Nur; Suseno, Jatmiko Endro
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (146.101 KB)

Abstract

The security system is very important for someone who often leaves his/her home or private room that can be used by perpetrators of crimes such as thieves. In this case, a tool is needed to anticipate this crime. Security is needed to protect ourselves and our valuable assets. In this study, a tool was used to secure a room by replacing a conventional door lock with a solenoid which can only be opened if entering passwords, cards or commands from the smartphone is correct. If entering a password or card is incorrect, then the system will lock the door automatically and sound an alarm for the specified time limit. if it is correct to enter a password or card then the system will open the solenoid and the door will open automatically without having to push the door. In addition to providing good safety, it also provides a practicality that is quite good because the door can be opened and locked automatically since we often forget ourselves to lock the door.
RANCANG BANGUN SISTEM KONTROL LAMPU, PAGAR, PINTU, DAN JENDELA (LPPJ) PADA MINIATUR RUMAH MENGGUNAKAN ARDUINO DAN TELEPON SELULE Aziz, Fariz Abdul; Sumariyah, Sumariyah
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (215.139 KB)

Abstract

The positive impact of technological advancements is to make it easier to use and to control electronic devices by a microcontroller. The aim of this research is to remotely control lights, fences, doors, and windows (LPPJ) on miniature homes using cellular phones connected to bluetooth using Arduino Mega 2560. This control system consisted of Arduino Mega 2560, LDR sensor, servo motor and motor servo2, DC motors, relays, and cellular phones. The workings of the LPPJ control system is when the LDR sensor detects sunlight, then it will give an order to the relay to turn on or off the light. In addition to using the LDR sensor to control the lights, the LPPJ system uses remote control by using cellular phones with communication via Bluetooth to turn on or off the light, to move the fence, door, and window by pressing the button on the cellphone. It is successfully designed and developed a control system of LPPJ on miniature homes using the cellular phones.
PENGARUH RASIO GRID TERHADAP KUALITAS RADIOGRAF FANTOM KEPALA Priyono, Setyo; Anam, Choirul; Budi, Wahyu Setia
BERKALA FISIKA Vol 23, No 1 (2020): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (177.698 KB)

Abstract

This study aims to determine the effect of the grid ratio on the quality of the radiographic examination of a head phantom. The study was conducted by using grid ratios of 5:1, 6:1, and 8:1, the head phantom. The focus-film distance (FFD) was 100 cm. In the antero-posterior projection used voltages of 70, 75, and 80 kVp with a current-time of 25 mAs, while in the lateral projection using voltages of 65, 70 and 75 kVp with a current-time of 20 mAs. The densities of radiographs were measured using a densitometer. Measurement was repeated in 10 locations. The contrast of radiograph was calculated as the difference between adjacent density values. The results showed that the higher level of the grid ratio would lower the density of radiograph, however it does not always give effect to the increase or decrease the contrast of radiographs. It was found that the optimal quality radiographs in antero-posterior projection at a grid ratio of 6:1 for tube voltage of 75 kVp with a current-time of 25 mAs, and in the lateral projections at a grid ratio of 5:1 grid for tube voltage of 75 kVp with a currenttime of 20 mAs.

Page 1 of 1 | Total Record : 6


Filter by Year

2020 2020


Filter By Issues
All Issue Vol 26, No 1 (2023): Berkala Fisika Vol 25, No 4 (2022): Berkala Fisika Vol 25, No 2 (2022): Berkala Fisika Vol 24, No 4 (2021): Berkala Fisika Vol 24, No 3 (2021): Berkala Fisika Vol 24, No 1 (2021): Berkala Fisika Vol 23, No 4 (2020): Berkala Fisika Vol 23, No 3 (2020): Berkala Fisika Vol 23, No 2 (2020): Berkala Fisika Vol 23, No 1 (2020): Berkala Fisika Vol 22, No 4 (2019): Berkala Fisika Vol. 22 No. 4 Tahun 2019 Vol 22, No 3 (2019): Berkala Fisika Vol. 22 No. 3 Tahun 2019 Vol 22, No 2 (2019): Berkala Fisika Vol. 22 No. 2 Tahun 2019 Vol 22, No 1 (2019): Berkala Fisika Vol. 22 No. 1 Tahun 2019 2015: Berkala Fisika Vol. 18 No. 4 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 3 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 2 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 1 Tahun 2015 2014: Berkala Fisika Vol. 17 No. 4 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 3 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 2 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 1 Tahun 2014 Vol 16, No 4 (2013): Berkala Fisika Vol 16, No 3 (2013): Berkala Fisika Vol 16, No 2 (2013): Berkala Fisika Vol 16, No 1 (2013): Berkala Fisika Vol 15, No 4 (2012): Berkala Fisika Vol 15, No 3 (2012): Berkala Fisika Vol 15, No 2 (2012): Berkala Fisika Vol 15, No 1 (2012): Berkala Fisika Vol 11, No 2 (2008): Berkala Fisika Vol 14, No 4 (2011): Berkala Fisika Vol 14, No 3 (2011): Berkala Fisika Vol 14, No 2 (2011): Berkala Fisika Vol 14, No 1 (2011): Berkala Fisika Vol 13, No 4 (2010): Berkala Fisika Vol 13, No 3 (2010): Berkala Fisika Vol 13, No 2 (2010): Berkala Fisika, Edisi Khusus Vol 13, No 2 (2010): Berkala Fisika Vol 13, No 1 (2010): Berkala Fisika Vol 12, No 4 (2009): Berkala Fisika Vol 12, No 3 (2009): Berkala Fisika Vol 12, No 2 (2009): Berkala Fisika Vol 12, No 1 (2009): Berkala Fisika Vol 11, No 4 (2008): Berkala Fisika Vol 11, No 3 (2008): Berkala Fisika Vol 11, No 1 (2008): Berkala Fisika Vol 10, No 4 (2007): Berkala Fisika Vol 10, No 3 (2007): Berkala Fisika Vol 10, No 2 (2007): Berkala Fisika Vol 10, No 1 (2007): Berkala Fisika Vol 9, No 4 (2006): Berkala Fisika Vol 9, No 3 (2006): Berkala Fisika Vol 9, No 2 (2006): Berkala Fisika Vol 9, No 1 (2006): Berkala Fisika More Issue