cover
Contact Name
Lorentius Wahana Dika
Contact Email
jmataoptik@gmail.com
Phone
+628179255773
Journal Mail Official
jmataoptik@gmail.com
Editorial Address
Jln. Pondok Aren Raya No.108A Bintaro Sektor IX, Kel. Pondok Aren, Kec. Pondok Aren, Kota Tangerang Selatan
Location
Kota tangerang selatan,
Banten
INDONESIA
Jurnal Mata Optik
ISSN : -     EISSN : 27468259     DOI : -
Core Subject : Health, Education,
Mata Optik : Jurnal Penelitian Mata Optik is aims to be a peer-reviewed platform and an authoritative source of information. We publish scientific writing in the form of research, reviews, studies, and conceptual or theoretical thinking in the fields of Indonesian refractionist and optician. All papers are peer-reviewed by at least two referees. Mata Optik is managed to be issued twice in every volume. The Scope of Jurnal Mata Optik is: 1. Refractive error and correction 2. Eye care 3. Optical Industry
Articles 57 Documents
PEMILIHAN BINGKAI KACAMATA YANG TEPAT UNTUK KONSUMEN DALAM MENINGKATKAN PELAYANAN PRIMA DI OPTIK MAHAKAM Jimmy Tandarto Chin; Zakaria Efendi; Ferry Doringin
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.1

Abstract

Penelitian ini bertujuan untuk menggali lebih dalam pemahaman tentang pemilihan bingkai kacamata yang tepat dan strategi meningkatkan penjualan di optikal (toko optik). Pemilihan kacamata yang tepat berkorelasi erat dengan kepuasan pelanggan karena bingkai yang tepat akan memberikan rasa nyaman pemakaian kacamata. Kepuasan pelanggan merupakan elemen penting dalam strategi meningkatkan penjualan di optikal. Pelayanan jasa, produk bingkai kacamata dan promosi yang tidak sesuai kebutuhan konsumen dapat mempengaruhi kemajuan optikal. Dengan menggunakan metode studi pustaka dan observasi kebiasan dan perilaku belanja konsumen di Optik Mahakam, penelitian ini juga akan membahas elemen-elemen penting dari pelayanan prima di optikal.. Hasil penelitian disajikan secara descriptif.dengan menegaskan mengenai pentingnya variasi produk, pelayanan jasa, promosi, dan kompetensi karyawan. Kata Kunci : Bingkai Kacamata, Optikal, Deskriptif, Tepat, Pelayanan Prima
KEGUNAAN HARDCOAT, ANTI REFLEKSI DAN LAPISAN HIDROPHOBIK PADA LENSA ORGANIK Putri Prasetyaningtyas; M. Wahyu Budiana; Murni Marlina Simarmata
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.2

Abstract

Pelapisan perlindungan pada lensa organik menawarkan beberapa kelebihan dibandingkan dengan kacamata tanpa lapisan perlindungan. Namun pemakaiannya harus diikuti oleh pemeliharaan yang baik dan tepat. Dalam penulisan ini, penulis menggunakan metode Deskriptif dari data kepustakaan baik cetak maupun elektronik. Salah satunya adalah karya Sarah Morgab dalam bukunya “The Complete Optometric Assistan” yang menyatakan bahwa lapisan anti refleksi dtidak hanya meningkatkan kualitas tapi mengurangi tampilan mengkilap pantulan dari permukaan lensa dan menghapus tampilan “seperti kaca” penampilan kacamata dan memungkinkan mata si pemakai terlihat dan memungkinkan kontak mata jadi lebih baik. Oleh karenanya diperlukan pemahaman akan kegunaan dari lapisan anti refleksi tersebut. Kata Kunci : Pelapisan, Kegunaan, Deskriptif, Lensa Organik, Nyaman
PROSES PEMBUATAN PATRUN MANUAL LENSA SINGLE VISION SPHERO CYLINDER Normisbah; Zakaria Efendi; Nisa Zakiati Umami
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.3

Abstract

Proses pembuatan patrun pada lensa single vision sphero cylinder di laboratorium optik memerlukan ketelitian yang tinggi untuk dapat menghasilkan kacamata yang sesuai keinginan pasien, dalam penulisan ini penulis menggunakan metode deskriptif dari data kepustakaan salah satunya karangan Clifford W Brooks dengan judul buku Essential For Ophthalmic Lens Finishing. Tujuan karya tulis ini adalah agar lensa single vision sphero cylinder yang di faset dapat memusatkan OC secara horisontal dan vertikal dengan tepat sehingga menghasilkan lensa dengan kualitas baik. Kata Kunci : Patrun, Lensa Single Vision Sphero Cylinder, Deskriptif, Tepat, Kualitas
METODE CROSS CYLINDER UNTUK PEMERIKSAAN ASTIGMATISME RENDAH Toni Wijaya; M. Wahyu Budiana; Lorentius Wahana Dika
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.4

Abstract

Salah satu timbulnya keluhan penglihatan pada penderita astigmatisme dengan axis yang tidak tepat adalah kurang tajam penglihatan, ketidaksempurnaan (distorsi) tajam penglihatan, berbayang atau tampak ganda saat melihat objek. Penentuan aksis pada penderita astigmatisme dapat dilakukan dengan tehnik pengaburan dan silinder silang. Pada karya tulis ini, penulis menggunakan pengumpulan data yang bersifat deskriptif dengan kepustakaan salah satunya karangan Andrew William Keirl dengan judul buku ”Clinical Optics and Refraction: A Guide for Optometrists, Contact Lens”. Tujuan dari teknik pemeriksaan refraksi menggunakan kedua metode tersebut di atas pada penderita astigmatisme adalah untuk mendapatkan kenyamanan penglihatan bagi penderita astigmatisme. Kata Kunci : Tajam Penglihatan, Astigmatisme, Deskriptif, Refraksi subjektif Kenyamanan Penglihatan.
PEMERIKSAAN REFRAKSI SUBYEKTIF PADA PENDERITA PRESBYOPIA DENGAN STATUS REFRAKSI EMMETROPIA Imam Setyana; Nensi Mesrani Tarigan; Opep Cahya Nugraha
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.6

Abstract

Abstract Accomodation is a mechanism that regulates the focus of the eyes to respond to visual stimulation by changing the refractive power of the crystaline lens. To focus near object, the cilliary muscle contracts which changes the shapes of the lens. However with increasing age, elasticity of the lens decreases causing anomalies of accomodation called presbyopia. The teatment of presbyopia is the prescription of appropriate convex glasses for near work. In this paper, the writer uses descriptive methods from the library data regarding subjective refraction to find the correction lens diopters to reach the best visual acuity. Keywords: Pattern, Single Vision Sphero Cylinder Lenses, Descriptive, Accurate, Quality
TABLE OF CONTENT JOURNAL MATA OPTIK VOL.1 NO.1 TAHUN 2020 Lorentius Wahana Dika
Jurnal Mata Optik Vol. 1 No. 1 (2020): Jurnal Mata Optik
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i1.8

Abstract

FITTING IDEAL DAN PENGARUHNYA TERHADAP KESTABILAN LENSA KONTAK LUNAK TORIK Darma Kusumah; Murni Marlina Simarmata; Ferry Doringin
Jurnal Mata Optik Vol. 1 No. 2 (2020): Bulan November
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i2.17

Abstract

Toric soft contact lenses are contact lenses that have silinderstrength so they can be used to correct astigmatism disorders. The difference in meridian strength involves a difference in thickness that affects the stability of the toric soft contact lens that is attached to the eye. One of the problems most frequently complained of by users of toric soft contact lenses is unstable visual acuity where when the soft toric contact lens is used the vision becomes unclear due to the soft toric contact lens that is attached to the eye rotating so that the axis shifts. This is often caused by the inaccuracy of contact lens Fitting that has not been carried out before trial installation, so conducting a trial first in recommending toric soft contact lenses is very important to ensure the stability of soft toric contact lenses when worn by users. This paper aims to determine and discuss that the ideal Fitting assessment greatly affects the stabilization of toric soft contact lenses.
PEMAKAIAN HIDDEN BEVEL LENSA CR-39 DENGAN AUTO GROOVER DAN KENYAMANAN PENGGUNA Andriani; Wahyu Budiana; Opep Cahya Nugraha; Nisa Zakiati Umami
Jurnal Mata Optik Vol. 1 No. 2 (2020): Bulan November
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i2.19

Abstract

Bevel Hidden manufacture lenses CR - 39 in optical dispensing laboratories using Autogroover engine requires high precision and skills so as to produce glasses that fit the patient's wishes, in this paper the author uses descriptive method of literature data one by David Wilson with the title of the book "Practical Optical Dispensing" bifocal lens that can focus both horizontally and can be completed in a placement center vertically so as to produce a lens with good quality
KARTU LOGMAR 50 CM DALAM PEMERIKSAAN REFRAKSI SUBYEKTIF Marta Angkawijaya; Bunyamin Rizki Abdilah; Nensi Tarigan; Kadaryati Kahfi
Jurnal Mata Optik Vol. 1 No. 2 (2020): Bulan November
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i2.21

Abstract

The recently challanges nowadays are do the eye examination without face to face. Condition of disability patients that physiologicly couldn’t bear at sitting position, the changes of customer behaviour and pandemic covid – 19 situation drives needs of - easy, convenient and safe - eye examination indirectly by cyberspace. Subjective Refraction eye examination using LogMAR Chart 50 cm would adress the problem of those challenges. Writer uses descriptive methods by literature and electronic media also, such as, The published one by European Board of Ophtalmologi Subcomittee , “American Academy of Ophtalmology” part. Visual Acuity Chart that elaborate visual acuity charts includes LogMAR chart which is more reliable, hence gives the more acurate visual acuity.
PENGLIHATAN ANAK DAN EFEKTIVITAS VITAMIN A Ronald Tandarto; Ferry Doringin; Zakaria Efendi
Jurnal Mata Optik Vol. 1 No. 2 (2020): Bulan November
Publisher : Akademi Refraksi Optisi dan Optometry Gapopin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54363/jmo.v1i2.22

Abstract

Vitamin A deficiency in chindren can cause night blindness, even total blidness. However, the effect of vitamin A deficiency is not limited on th both sight problems. Thus, the author will describe the importance of vitamin A to five senses of children. As quoted in the book Blomhoff R, in his book Review of Retinoid Metabolism and Function 'Vitamin A plays a role in the formation of the sense of sight for humans', therefore the participation of parents and health workers supported by the government can prevent the impact that occurs if vitamin A deficiency occurs in children's vision.