Aplikasi Metode Neuro-Fuzzy Pada Sistem Pengendalian Antisurge Kompresor Abadi, Imam; Siti Aisjah, Aulia; N.S., Riftyanto
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (154.891 KB) | DOI: 10.9744/jte.6.2.

Abstract

Operating condition that unstabil to compressor is called surge, which defined as self oscillations between pressure and flow, that can cause serious damage to compressor. Because of this problem, it is necessary to design of antisurge compressor control. Using conventional control like PI (Proportional and Integral) controller, effective only for certain condition but uneffective for condition with non linier systems. To handle this problems, it is proposed using Neuro-Fuzzy controller. Application of these system will improve performance indicator of PI controller applied in combination Neural Network and Fuzzy Logic Control to get robust performance system. For respon transient experiment, with differential pressure ( P) 37.91 kg/cm2, Neuro-Fuzzy controller result better performance corcerning to PI controller with settling time 7.3 seconds, maximum overshoot 11.6223 %, error percent 0.0563013 % and error steady state 0.0213438 kg/cm2. Whereas, PI controller result settling time 22.3 seconds, maximum overshoot 17.8996 %, error percent 0.185294 % and error steady state 0.0702449 kg/cm2. For respon transient system simulation with noise and respon transient simulation with noise and load, Neuro-Fuzzy controller also shows better performance with settling time, maximum overshoot and error steady state smaller than PI controller. Abstract in Bahasa Indonesia : Salah satu bentuk kondisi operasi yang tidak stabil pada kompresor adalah kondisi yang disebut surge, dimana terjadi ketidakstabilan antara aliran dan tekanan yang dapat menyebabkan kerusakan yang serius pada kompresor. Oleh karena itu akan dirancang suatu pengendalian anti surge pada kompresor. Perancangan dilakukan dengan pengendali neuro-fuzzy, yang menggabungkan kemampuan belajar Neural Network dengan kemampuan pengambilan keputusan pada fuzzy. Dengan harapan akan diperoleh performansi yang lebih baik daripada pengendali PI yang nantinya dijadikan sebagai pembanding. Pada simulasi uji respon sistem, dengan setpoint beda tekanan ( P) sebesar 37,91 kg/cm2, pengendali Neuro-Fuzzy menghasilkan performansi yang lebih baik dari pengendali PI dengan settling time 7,3 detik, maksimum overshoot 11,6223 %, persen error 0,0563013 % dan error steady state 0,0213438 kg/cm2. Sedangkan pengendali PI menghasilkan settling time 22,3 detik, maksimum overshoot 17,8996 %, persen error 0,185294 % dan error steady state 0,0702449 kg/cm2. Kata kunci: antisurge, simulasi, neuro-fuzzy, settling time, maksimum overshoot, persen error, error steady state.
Perbaikan Stabilitas Dinamik Melalui Penjadwalan Ulang Pembangkit Menggunakan Sensitivitas Trayektori Fridz Galla, Wellem
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (193.827 KB) | DOI: 10.9744/jte.6.2.

Abstract

The optimum operation condition of power system obtained from optimal calculation is determined without considering its dynamic stability limit. If the load of system is changed, power generating should accommodate the changes to make the demand of load supplied. This changing will shift dynamic stability system condition. This article deals with dynamic stability correction as a result of load of system changing by generation rescheduling using the biggest sensitivity of the sensitivity trajectory variable with respect to its parameters i.e. the power out put generators. The simulation in the 3-machines 9 bus power system with 25%, 50% and 75% load increasing of initial load caused eigen value position better, 1,2 and 3,4 of 25% load increasing each of them is 1,1 x 10-5 and 0,5 x 10-5, to 50% load increasing is 3,47 x 10-4 and 0,98 x 10-4, to 75% load increasing is 1,11 x 10-4 and 1,67 x 10-4 more far from imaginary axis compare to before generating rescheduling. The simulation result with this method indicates that there is dynamic stability correction, in this manner the system operates with better dynamic stability condition. Abstract in Bahasa Indonesia : Kondisi operasi optimum sistem tenaga yang diperoleh dari perhitungan optimasi dilakukan tanpa memasukkan batas stabilitas dinamiknya. Jika terjadi perubahan pada beban maka pembangkitan daya harus menyesuaikan perubahan tersebut agar tetap memenuhi kebutuhan beban. Perubahan pembangkitan akan mengubah kondisi stabilitas dinamik sistem. Makalah ini membahas tentang perbaikan stabilitas dinamik akibat perubahan beban sistem melalui penjadwalan ulang pembangkit menggunakan sensitivitas terbesar dari sensitivitas trayektori variabel keadaan sistem yaitu sudut rotor relatif terhadap parameternya yaitu daya output generator. Pengujian pada sistem tenaga 3-mesin 9-bus dengan kenaikkan beban 25%, 50% dan 75% dari beban dasar menyebabkan letak nilai eigen terkait lebih baik, 1,2 dan 3,4 untuk kenaikkan beban 25% masing-masing adalah 1,1 x 10-5 dan 0,5 x 10-5, untuk kenaikkan beban 50% adalah 3,47 x 10-4 dan 0,98 x 10-4, untuk kenaikkan beban 75% adalah 1,11 x 10-4 dan 1,67 x 10-4 lebih jauh dari sumbu imajiner dibandingkan sebelum penjadwalan ulang pembangkit. Hasil pengujian dengan metode ini menunjukkan adanya perbaikan stabilitas dinamik, sehingga sistem tenaga beroperasi dengan kondisi stabilitas dinamik yang lebih baik. Kata kunci: stabilitas dinamik, penjadwalan ulang pembangkit, perhitungan optimasi, dan sensitivitas trayektori.
Communication Between TSX Micro 37-21 PLCs on Beverage Production Plant Wicaksono, Handy; Udayana, Chandra; Ferdinando, Hany
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (155.07 KB) | DOI: 10.9744/jte.6.2.

Abstract

Programmable Logic Controller (PLC) is the most famous controller in industry. Because the process in industry is getting more and more complex than before, the usage of more than one PLC is needed and the communication between them have to be existed. This paper describes about the study of communicating two Schneider TSX Micro 37-21 PLCs in order to control the miniature of beverage production. The usual (and expensive) way to communicate them is using converter module TSX P ACC 01. Less expensive way uses original converter cable TSX PCX 1031 that connect to the ports of PLCs (TER and AUX port) which will be explained here. PL7 Pro V 4.0 software is used to program the PLCs. The communication cannot be established due to some improper addressing. The exploration is continued to the serial communication. It is found that the system uses RS 485. Abstract in Bahasa Indonesia : Programmable logic Controller (PLC) adalah kontroler yang paling populer di dunia industri. Karena proses di industri semakin kompleks, diperlukan penggunaan lebih dari satu PLC yang dapat berkomunikasi satu sama lain. Penelitian ini menjelaskan tentang studi dalam mengkomunikasikan 2 PLC TSX Micro 37-21 dari Schneider untuk mengendalikna miniatur produksi minuman. Cara yang umum (dan mahal) ialah dengan menggunakan modul TSX P ACC 01. Cara yang lebih murah ialah menggunakan kabel converter asli TSX PCX 1031 yang menghubungkan port LPC (TER dan AUX port) yang akan dijelaskan di sini. Software PL7 Pro V 4.0 digunakan untuk memprogram PLC. Komunikasi tidak dapat dilakukan karena pengalamatan yang kurang tepat. Eksplorasi dilanjutkan kepada komunikasi serialnya. Dari percobaan ditemukan bahwa sistem ini menggunakan RS 485. Kata kunci: PLC TSX Micro 37-21 Schneider, komunikasi antar PLC, miniatur plant produksi minuman.
Peningkatan Kapasitas Sel CDMA pada Daerah Urban dengan Partisi Sel Ulvan, Melvi
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (184.754 KB) | DOI: 10.9744/jte.6.2.

Abstract

A cell partition is expected to reduce the inter-cell interference, increasing capacity and optimize the frequency spectrum allocation. The purpose of cell partition is to increase the capacity of inner cell which have lower power and different frequency to outer cell. This paper shows how generous the capacity increased after the partition has been done. The calculation of MAPL and the link budget have been done have been done as well. The propagation model of Walfisch-Ikegami has been used in the paper. As the result, It has been found that the site capacity was increased, therefore the order of blocking can be reduced. The cell partition is appropriate for the area with high-level of traffic. Abstract in Bahasa Indonesia : Partisi sel diharapkan dapat mengurangi pengaruh interferesi, meningkatkan kapasitas pada sel tersebut dan dapat mengoptimalkan spektrum frekuensi yang tersedia. Tujuan partisi sel adalah untuk meningkatkan kapasitas, terutama kapasitas untuk inner cell yang daya lebih rendah dan frekuensi yang berbeda dari outer cell. Makalah ini akan menunjukkan seberapa besar peningkatan kapasitas setelah dilakukan partisi. Perhitungan Maximum Allowable Path Loss (MAPL) dan link budget untuk arah forward dan reverse telah dilakukan. Model propagasi yang digunakan adalah model propagasi daerah urban, Walfisch-Ikegami, Kesimpulan yang didapat adalah kapasitas pada site dapat ditingkatkan sehingga keadaan blocking pada sel tersebut dapat dikurangi. Metode partisi sel ini sangat cocok untuk daerah urban yang mempunyai tingkat kepadatan traffic yang tinggi. Kata kunci: kapasitas sel, partisi sel, perencanaan sel, selular CDMA.
Adaptive Blind Channel Equalization for Mobile Multimedia Communication Irawan, Jusak
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (198.371 KB) | DOI: 10.9744/jte.6.2.

Abstract

In the last decade much research effort has been dedicated to deal with the issues of wireless multimedia communications, in particular bandwidth limitation and channel impairment. We have recently proposed a new scheme for blind equalization called sinusoidally-distributed dither signed-error constant modulus algorithm (S-DSE-CMA). In this paper, we test this scheme for wireless image transmission. Simulation showed that the low complexity of implementation and fast convergence rate are the major advantages of employing the new scheme for multimedia applications. It is also shown, from perceptual-based analysis as well as objective measurements using peak signal-to-noise ratio (PSNR) of the recovered image, that the recently-proposed blind adaptive equalization algorithm outperforms existing methods, e.g., uniformly-distributed DSE-CMA. Abstract in Bahasa Indonesia : Dalam beberapa tahun terakhir, usaha-usaha penelitian dilakukan untuk menyelesaikan permasalahan-permasalahan yang ada pada bidang multimedia untuk komunikasi nirkabel. Permasalahan-permasalahan tersebut misalnya keterbatasan lebar jalur dan distorsi kanal komunikasi. Dalam paper ini, sebuah algoritma baru dibuat untuk ekualisasi secara buta terhadap kanal komunikasi nirkabel. Algoritma tersebut disebut sebagai sinusoidally-distributed dither signed-error constant modulus algorithm (S-DSE-CMA). Pengujian dilakukan dengan mengirimkan informasi dalam bentuk gambar yang ditransmisikan pada kanal komunikasi nirkabel. Dari pengujian didapatkan bahwa dengan menggunakan algoritma baru ini terdapat dua kelebihan dibandingkan algoritma yang telah ada (uniformly-distributed DSE-CMA) yaitu: kompleksitas algoritma lebih rendah dan kecepatan konvergensi dari algoritma ini lebih tinggi. Kata kunci: Ekualisasi, interferensi antar simbol, algoritma constant modulus, multimedia.
An Example of Utilizing Stochastic Approach for Investigating Network Constraints (Congestions) on Horizontally Operated Power Systems with Distributed Generation Reza, M.; Papaefthymiou, G.; H. Schavemaker1, P.; , 2
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (156.596 KB) | DOI: 10.9744/jte.6.2.

Abstract

This paper shows an example of a stochastic approach to study the impact of distributed generation (DG) on the network constraints (congestions) in power systems. We assume the DG units to be customer-owned, so that they can be connected to or disconnected from the power system by their owners at random. Therefore, the DG units generate power in a stochastic way. The load in the system shows a random behavior too, and the probability distribution of the aggregated generated power and load demand of the distribution system are calculated using Monte Carlo Simulation (MCS).The network constraints (congestions) are evaluated based on the probability distributions of the power flows that result from the simulations. The method that is applied in this paper, shows that looking at the network constraints with a stochastic approach gives a more complete picture of the network than applying a deterministic method, especially when non-dispatchable DG units play a dominant role. Abstract in Bahasa Indonesia : Makalah ini menunjukkan sebuah contoh pendekatan stokastik untuk mempelajari pengaruh dari pembangkit listrik tersebar (PLT) terhadap konjesti pada jaringan tenaga listrik. Dalam makalah ini diasumsikan bahwa setiap unit PLT dimiliki oleh pemilik independen, sehingga setiap PLT dapat disambung ke atau dilepas dari jaringan listrik oleh pemiliknya secara acak. Sebagai hasilnya, secara keseluruhan PLT tersebut membangkitkan tenaga listrik secara stokastik. Beban dalam jaringan listrik juga memiliki sifat acak. Distribusi peluang dari gabungan pembangkitan dan beban di dalam jaringan distribusi dikalkulasikan dengan menggunakan Simulasi Monte Carlo. Konjesti jaringan dievaluasi dengan berdasarkan pada distribusi peluang dari aliran daya yang dihasilkan melalui simulasi. Metoda yang diterapkan pada makalah ini menunjukkan bahwa pendekatan stokastik memberikan gambaran konjesti jaringan yang lebih lengkap daripada pendekatan deterministik, terutama ketika unit-unit PLT yang dominant digunakan tidak dikendalikan secara terpusat. Kata kunci: system tenaga listrik, pembangkit listrik tersebar, aliran daya, konjesti jaringan, pendekatan stokastik, simulasi Monte Carlo.
AMPLIFIER DENGAN UMPAN BALIK AKUSTIK UNTUK MEMPERKUAT FREKUENSI RENDAH PENGUAT AUDIO Sugiarto, Indar; TDS, Yohanes; , Suryadi
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (147.948 KB) | DOI: 10.9744/jte.6.2.

Abstract

This paper shows an example of a stochastic approach to study the impact of distributed generation (DG) on the network constraints (congestions) in power systems. We assume the DG units to be customer-owned, so that they can be connected to or disconnected from the power system by their owners at random. Therefore, the DG units generate power in a stochastic way. The load in the system shows a random behavior too, and the probability distribution of the aggregated generated power and load demand of the distribution system are calculated using Monte Carlo Simulation (MCS).The network constraints (congestions) are evaluated based on the probability distributions of the power flows that result from the simulations. The method that is applied in this paper, shows that looking at the network constraints with a stochastic approach gives a more complete picture of the network than applying a deterministic method, especially when non-dispatchable DG units play a dominant role. Abstract in Bahasa Indonesia : Makalah ini menunjukkan sebuah contoh pendekatan stokastik untuk mempelajari pengaruh dari pembangkit listrik tersebar (PLT) terhadap konjesti pada jaringan tenaga listrik. Dalam makalah ini diasumsikan bahwa setiap unit PLT dimiliki oleh pemilik independen, sehingga setiap PLT dapat disambung ke atau dilepas dari jaringan listrik oleh pemiliknya secara acak. Sebagai hasilnya, secara keseluruhan PLT tersebut membangkitkan tenaga listrik secara stokastik. Beban dalam jaringan listrik juga memiliki sifat acak. Distribusi peluang dari gabungan pembangkitan dan beban di dalam jaringan distribusi dikalkulasikan dengan menggunakan Simulasi Monte Carlo. Konjesti jaringan dievaluasi dengan berdasarkan pada distribusi peluang dari aliran daya yang dihasilkan melalui simulasi. Metoda yang diterapkan pada makalah ini menunjukkan bahwa pendekatan stokastik memberikan gambaran konjesti jaringan yang lebih lengkap daripada pendekatan deterministik, terutama ketika unit-unit PLT yang dominant digunakan tidak dikendalikan secara terpusat. Kata kunci: system tenaga listrik, pembangkit listrik tersebar, aliran daya, konjesti jaringan, pendekatan stokastik, simulasi Monte Carlo. .
Studi Tentang Penguat Cascade Dua Tingkat Menggunakan JFET Kartiko Dirgantoro, Tjahjo; Khoswanto, Handry; Ferdinando, Hany
Jurnal Teknik Elektro Vol 6, No 2 (2006): SEPTEMBER 2006
Publisher : Institute of Research and Community Outreach

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.9744/jte.6.2.

Abstract

Cascade amplifier has more than one stages on the circuit configurations. The purpose of cascade amplifier using JFET is to get larger voltage gain also with large input impedance. Except CS-CS cascade amplifier, cascade amplifier using JFET never studied in every literature. This research focuses on the two stage cascade amplifier using JFET for nine circuit configurations, i.e. CS-CS, CS-CD, CS-CG, CD-CS, CD-CD, CD-CG, CG-CS, CG-CD, and CG-CG. From those nine configurations, the interest is to see gain characteristic and to compare one another. This paper uses JFET 2N5457 type with specification IDSS = 5 mA and VGS(off) = -6 V also specified one of DC bias parameter in the active region that is IDQ = 2 mA. The voltage gain is measured by giving voltage input from 50 mV (Vp-p) until 1000 mV (Vp-p) at 1 KHz. There are some recommendations, one of them is that the CS-CS cascade amplifier is amplifier with the largest voltage gain. Abstract in Bahasa Indonesia : Sistem cascade dalam suatu penguat berarti mempunyai lebih dari satu tingkat dalam konfigurasi rangkaiannya. Penguat sistem cascade menggunakan JFET bertujuan untuk mendapatkan penguatan tegangan yang lebih besar dengan impedansi masukan yang besar pula. Kecuali penguat cascade CS-CS, penguat cascade menggunakan JFET tidak pernah dibahas dalam literatur yang ada. Pada penguat sistem cascade menggunakan JFET dua tingkat ini terdapat sembilan konfigurasi rangkaian, yaitu CS-CS, CS-CD, CS-CG, CD-CS, CD-CD, CD-CG, CG-CS, CG-CD, dan CG-CG. Dari kesembilan konfigurasi itu akan dilihat karakteristik penguatannya dan dibandingkan satu sama lain. Penelitian menggunakan JFET tipe 2N5457 dengan spesifikasi teknis IDSS = 5 mA dan VGS(off) = -6 V serta ditetapkan salah satu parameter DC bias pada daerah aktif yaitu IDQ = 2 mA. Pengujian yang dilakukan adalah dengan mengukur penguatan tegangan yaitu memberikan variasi tegangan masukan dari 50 mV (Vp-p) sampai 1000 mV (Vp-p) dan dilihat besar penguatan tegangannya pada tegangan keluaran. Pengujian dilakukan pada frekuensi 1 KHz. Dihasilkan beberapa rekomendasi, satu diantaranya yaitu bahwa penguat cascade CS-CS adalah penguat yang mempunyai penguatan tegangan terbesar. Kata kunci: JFET, penguat cascade

Page 1 of 1 | Total Record : 8