cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Perangkat Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Perangkat Nuklir (Journal of Nuclear Equepments), terbit dua kali setiap tahun bulan Mei dan November sejak 2007. Partisipasi aktif berupa saran dan pendapat maupun kritik yang bersifat membangun sangat diharapkan untuk meningkatkan kualitas jurnal. Alamat: Gedung 71, Kawasan Puspiptek Serpong, Tangerang 15310, Indonesia, Telepon: (021) 7560896, Penerbit: Pusat Rekayasa Perangkat Nuklir - BATAN
Arjuna Subject : -
Articles 104 Documents
SISTEM DETEKSI MONITOR LINGKUNGAN Leli Yuniarsari; Istofa Istofa; Sukandar Sukandar
Jurnal Perangkat Nuklir Vol 9, No 01 (2015): juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (167.873 KB)

Abstract

SISTEM DETEKSI MONITOR LINGKUNGAN adalah bagian dari  perangkat pemantau radioaktifitas lingkungan instalasi nuklir, yang berfungsi  untuk   memantau radiasi di lingkungan  instalasi nuklir. Perangkat ini terdiri dari sistem deteksi radiasi gamma dan sistem deteksi cuaca, (meliputi arah angin, kecepatan angin serta curah hujan). Keluaran dari perangkat ini akan diolah oleh pengolah data Arduino Uno menjadi data dengan standar tertentu kemudian  ditampilkan dalam sebuah  situs. Sistem deteksi radiasi untuk mendeteksi radiasi gamma menggunakan detektor NaI(Tl) dan GM yang digunakan untuk mengubah radiasi yang datang  menjadi sinyal listrik yang diperkuat oleh preamplifier dan amplifier untuk selanjutnya diubah menjadi pulsa kotak. Sistem deteksi cuaca, prinsip kerjanya menggunakan sistem saklar. Angin yang datang dengan kecepatan tertentu akan menutup saklar   dan  menghasilkan tegangan atau pulsa yang dapat diukur atau dihitung. Nilai inilah yang akan diinterpretasikan menjadi arah angin dan kecepatan angin.  Demikian juga halnya dengan curah hujan, banyaknya air dalam jumlah tertentu dapat menutup saklar yang berarti ada satu pulsa yang datang. Hasil pengujian untuk sistem deteksi radiasi,  keluaran yang dihasilkan  berupa  pulsa kotak sebesar 4 volt dengan menggunakan detektor NaI(Tl) dan  4,4 volt untuk detektor GM. Untuk sistem deteksi cuaca , pada dasarnya sudah bisa mendeteksi arah angin,  kecepatan angin  dan curah hujan hanya saja  untuk mengetahui keakuratannya  diperlukan penelitian lebih lanjut dan hasilnya dibandingkan dengan alat-alat standar yang tersedia di BMKG. Kata kunci: sistem deteksi radiasi, deteksi  cuaca AN ENVIRONMENTAL MONITORING DETECTION SYSTEM, is part of radiation detection of the nuclear facilities engineering activities within nuclear facilities. The system comprised of gamma-ray radiation detector and weather detection which includes anemometer to detect the wind direction and speed, as well as rain gauge to measure the rainfall in a period of time. Data acquisition of the output is processed by Arduino Uno system which transformed the data into a particular standard and then displayed online in the website. The radiation detection system uses gamma-ray detector of NaI(Tl) and GM which convert the radiation detected into electric pulse to be fed into a pre-amp and amplifier and modified into square pulse. The weather detection system on the other hand works based on switch principle. For example, the wind with a certain speed could turn on a switch in the system and produce a voltage or pulse which can be measured. This value will then be interpreted as the wind direction and speed. Likewise for the rainfall gauge, the volume of water entering the bucket will turn the switch on, at the same time producing 1 pulse. The result of the experiment shows that for radiation detection system the output is a square pulse 4 volts by using detector NaI(Tl) and 4.4 volts by using detector GM. For weather detection system, basically was able to detect the wind direction, wind speed and rainfall just to find out further research is needed accuracy and the results compared with the standard tools available in BMKG. Keywords: radiation detector, weather detection
PERANGKAT PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR Wiranto Budi Santoso; Istofa Istofa; Budi Santoso; Yan Bony Marsahala
Jurnal Perangkat Nuklir Vol 5, No 2 (2011): Nopember 2011
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (166.854 KB)

Abstract

ENGINEERING OF FLUOROSCENE SCREEN BASED X-RAY IMAGE CAPTURING EQUIPMENT. The engineering of fluoroscene screen based x-ray image capturing equipment has been done. An x-ray machine is a medical diagnoses equipment which can produce anatomical body structure images without carrying out operation. In conventional x-ray machine, imaging results are captured by utilizing films. Then the film is developed to get a body organ image so that it can be directly observed by a doctor. This film developing process generally uses chemical substances and it needs times and additional expenses. Beside conventional x-ray machine, now days there are x-ray machines which equipped with solid state based image capturing modules. In this type of x-ray machine, the resulting image is directly converted to digital images. Furthermore this image can be easily processed in computer. But the price of this type of modules are very expensive. Based on the above problems, this activity will be carried out to develop an x-ray image capturing module which can produce digital image and low production cost. In this activity, it will carry out an engineering of a fluorescence screen-based x-ray image capturing module. This module consists of a fluorescence screen which will convert x-ray to visible ray, a CCD camera, and a control and data acquisition module, and it will be connected to a computer as digital image processor. By using this module, resulting images from x-ray machine can be transferred to computer in the form of digital images. Compared to conventional way which using films, the advantages of using this module is more environmental friendly since there is no chemical substances used. Furthermore this module can shorten processing time and cost since the resulting image can be produced directly in digital form which can be cheaply and easily displayed or printed. But, in order to be applicable for a medical diagnoses tool, it needs data which show affectivity of this module compared to conventional film. Therefore, in this activity besides engineering module and functional test, it also can be carry out performance comparison by means of comparing between resulting images got by this module and by film. From the result, it can be concluded that this equipment has not been applicable for medical purposes. The resulting images are not clearer compared to x-ray film images. Therefore it needs more research to increase images intensity before they are captured by camera. The camera being used should capable to be adjust its light intensity reception.  PEREKAYASAAN PERANGKAT PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR.. Perekayasaan perangkat penangkap citra sinar-x berbasis layar pendar telah dilakukan. Pesawat sinar-x merupakan salah satu alat diagnosa medis yang dapat mencitrakan struktur anatomi tubuh tanpa melalui operasi. Pada pesawat sinar-x konvensional, hasil pencitraan ditangkap dengan menggunakan film, kemudian film tersebut dicuci untuk mendapatkan citra organ tubuh sehingga bisa diamati langsung oleh dokter. Proses pencucian film ini umumnya menggunakan bahan kimia, membutuhkan waktu serta biaya tambahan. Selain pesawat sinar-x konvensional, saat ini sudah ada pesawat sinar-x yang sudah dilengkapi dengan modul penangkap citra berbasis teknologi solid state. Pada pesawat sinar-x jenis ini, hasil pencitraan langsung diubah menjadi citra digital yang selanjutnya dapat diproses dengan mudah di komputer. Akan tetapi, harga modul jenis ini masih sangat mahal. Berangkat dari permasalahan-permasalahan inilah maka kami melakukan penelitian yang bertujuan untuk mengembangkan modul penangkap citra sinar-x yang dapat menghasilkan citra digital dan dengan biaya produksi yang murah. Pada penelitian ini, akan dilakukan perekayasaan modul penangkap citra sinar-x berbasis layar pendar. Modul ini terdiri dari fluorescence screen yang akan mengubah sinar-x menjadi cahaya tampak, CCD kamera, serta modul kendali dan akusisi data hasil pencitraan yang dihubungkan ke komputer sebagai pengolah citra digital. Dengan menggunakan modul ini, hasil pencitraan dari pesawat sinar-x segera bisa ditransfer ke komputer sebagai citra digital. Dibandingkan dengan cara konvensional yang menggunakan film, keuntungan dari penggunaan modul ini adalah lebih ramah lingkungan karena tidak menggunakan bahan kimia untuk mendapatkan hasil pencitraan, kemudian menghemat waktu dan biaya karena hasil pencitraan segera bisa diperoleh dalam bentuk berkas digital yang dapat ditampilkan maupun dicetak dengan murah dan mudah. Akan tetapi, agar bisa diaplikasikan untuk diagnosa medis, perlu ada data yang menunjukkan bagaimana efektifitas dari modul ini jika dibandingkan dengan film konvensional. Oleh karena itu, pada penelitian ini selain perekayasaan modul dan uji fungsi, juga akan dilakukan pembandingan unjuk kerja dengan cara membandingkan hasil pencitraan yang diperoleh menggunakan modul yang dibuat dan hasil pencitraan yang ditangkap dengan film. Dari hasil yang diperoleh, disimpulkan bahwa perangkat ini belum dapat diaplikasikan untuk keperluan medis. Citra yang didapatkan belum setajam hasil pencitraan dari film. Perlu dilakukan penelitian lebih lanjut untuk memperkuat citra yang dihasilkan oleh layar pendar sebelum ditangkap oleh kamera. Kamera yang digunakan sebaiknya dapat diatur kemampuan penerimaan intensitas cahayanya.
MODEL SISTEM DINAMIK TANGKI AIR MENGGUNAKAN IDENTIFIKASI SISTEM NONLINEAR HAMMERSTEIN-WIENER Arjoni Amir
Jurnal Perangkat Nuklir Vol 2, No 01 (2013): Mei 2008
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (786.97 KB)

Abstract

A DYNAMIC SYSTEM MODEL FOR A WATER TANK USING NONLINEAR HAMMERSTEIN-WIENER SYSTEM !DENTIFICA TlON. It has been simulated experiment at a model two water tanks connected in serial using nonlinear Hammerstein Wiener system identification technique. The dynamic system to be evaluatedis taken from the voltage change of water pump as input parameter and the second tank water level as output parameter. Relationship of these parameters are SISO (Single Input,single Output) and nonlinear. Dynamic system between these parameters is expressed in a record of couple of data input-output. Combination of input parameter nonlinear block, linear block, output parameter nonlinear block, delay time nk, and application of both estimator nonlinearity piecewiece linear and sigmoidnetwork with certain nonlinear number of block will yield some nonlinear Hammerstein Wiener model structure accurately. The result of the simulation experiment yield nonlinear Hammerstein Wiener model structure is indicated by value of Loss Function (small) 0.00026746, criterion of Final Prediction Error 0.0002859, assess Best Fit 89.49 , Fit 90.32 , orde of model structure [nb = 1, ru= 6, nk = 1J, and a sum of nonlinear block (input nonlinearity and output nonlinearity), 10.   MODEL SISTEM DINAMIK TANGKI AIR MENGGUNAKAN IDENTIFIKASI SISTEM NONLINEAR HAMMERSTEIN-WIENER. Telah dilakukan percobaan simulasi pemodelan sistem dinamik dua tangki air yang dihubungkan secara seri menggunakan tehnik identifikasi sistem nonlinear Hammerstein-Wiener. Sistem dinamik yang terjadi ditinjau dari perubahan tegangan listrik dari pompa air sebagai parameter input dan level air dalam tangki kedua sebagai parameter output. Hubungan kedua parameter ini adalah SISO (Single Input Single Output) dan nonlinear. Sistem dinamika antara kedua parameter ini dinyatakan dalam rekaman pasangan data input-output. Kombinasi parameter input blok nonlinear, blok linear, parameter output blok nonlinear, waktu delay nk, dan pemakaian estimator nonlinearity seperti piecewiece linear serta sigmoid network dengan jumlah blok nonlinearity tertentu akan menghasilkan beberapa struktur model nonlinear Hammerstein-Wiener yang akurat. Dari hasil percobaan simulasi diperoleh struktur model nonlinear Hammerstein-Wiener yang diindikasikan dengan nilai Loss Function (LF) yang kecil yaitu 0.00026746, kriteria Final Prediction Error yaitu 0.0002859 dan nilai Best Fit yaitu 89.49 , Fit 90.32 , orde struktur model [nb = 1, n, = 6, nk = 1J, dan dengan masing-masing jumlah blok nonlinear (input nonlinearity dan output nonlinearity) adalah 10.
PEMANFAATAN PENCACAHAN MONOTONIK DETEKTOR UNTUK MEMINIMALKAN ALARM PALSU PADA PORTAL MONITOR RADIASI Ahmad Rifai; Agus Cahyono
Jurnal Perangkat Nuklir Vol 8, No 2 (2014): Nopember 2014
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (331.764 KB)

Abstract

PEMANFAATAN PENCACAHAN MONOTONIK DETEKTOR UNTUK MEMINIMALKAN ALARM PALSU PADA PORTAL MONITOR RADIASI. Portal monitor radiasi (PMR) berperan penting dalam pencegahan penyalahgunaan dan penyelundupan bahan radioaktif melaluipendeteksian terhadap kendaraan di titik-titik pemeriksaan, seperti pelabuhan laut dan udara, serta fasilitas-fasilitas industri, kesehatan, dan nuklir. Kinerja PMR dicirikan oleh rendahnya kejadian alarm palsu. Penentuan batas ambang alarm pada PMR bersifat variatif dan subyektif, karena banyak faktor yang harus diperhitungkan. Salah satunya adalah cacah latar yang berfluktuasi. Penetapan batas ambang alarm dapat dilakukan dengan memanfaatkan sifat monotonik pencacahan dari detektor. Makalah ini menguraikan suatu simulasi sumber radioaktif yang bergerak mendekati/menjauhi detektor portal monitor. Teknik Moving Average Filter digunakan pada analisis statistik dalam simulasi ini untuk memperoleh deretan data (data series). Perbedaan(difference) intensitas radiasi menentukan kemiringan (slope) deret data pencacahan yangdibangkitkan. Hasil yang diperoleh menunjukkan apakah detektor mencacah monotonik naik atau turun, sehingga batas ambang alarm dapat ditetapkan dalam rangka untuk meminimalkan terjadinya alarm palsu.Kata kunci: Alarm palsu, portal monitor radiasi, pencacahan monotonikTHE USE OF DETECTOR’S MONOTONIC COUNTING TO MINIMIZE FALSE ALARM ONRADIATION PORTAL MONITOR. Radiation portal monitor (RPM) has essential role in preventing the diversion and smuggling of radioactive material by detection of vehicles at check-points, such as seaport and airport, as well as industrial, health, and nuclear facilities. The RPM performance is characterized by low number of false alarm occurrences. The alarm threshold setting varies and is subjective, because there are many factors that should be considered. One of them is fluctuating background. The alarm threshold can be set by using detector’s monotonic counting. This paperdescribes a simulation of a radioactive source moving toward/leaving from the detector of RPM. The moving average filter is used in the statistical analysis. The difference of radiation intensity defines the slope of the generated data. The results obtained indicate whether the detector iscounting monotonically increasing or decreasing, so that the alarm threshold can be set in order to minimize the occurrence of false alarm.Keywords: False alarm, radiation portal monitor, monotonic counting
DESAIN KONSEPTUAL PERISAI BIOLOGI IRRADIATOR GAMMA Co-60 Sutomo Sutomo; Petrus Zakaria; Edy Karyanta
Jurnal Perangkat Nuklir Vol 6, No 1 (2012): Juni 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (5293.137 KB)

Abstract

A conceptual design of biological shielding for Co-60 gamma irradiator having capacity of 200 kCi has been performed. Based on the available requirements, the shielding material used for irradiation chamber is normal concrete and the irradiation chamber is designed such that the distance between source (when being used) and wall is 3.5 m. The structure of the building is designed in cube of 7 m × 10 m × 4 m. Normal concrete is concrete using raw material of portland cement, coarse and fine aggregate plus water. The concrete density ranges from 2200 to 2500 kg/m3.For this design, the concrete density selected is 2350 kg/m3, considering the ease of procuring the raw material needed as defined by the decree of Bapeten chairment No.11/Ka-Bapeten/VI-99, in order to make exposure doses less than 0,25 mR/hour, the concrete shielding thickness has to be 1.5 m. Desain Konseptual Perisai Biologi Irradiator Gamma Co-60 kapasitas 200 kCi telah dilakukan. Berdasarkan persyaratan yang ada, bahan perisai ruang irradiasi yang dipilih adalah beton normal dan ruang irradiasi didesain dengan ketentuan jarak sumber (saat sedang digunakan) terhadap dinding dan atap 3,5 m. Desain bangunan ini berbentuk kubus atau kotak dengan ukuran 7 m x10 m x4 m. Beton normal adalah beton dengan bahan baku semen portland, agregat kasar dan halus, serta air. Beton ini memiliki berat jenis berkisar 2200 – 2500kg/m3. Desain ini memilih berat jenis beton 2350kg/m3 karena pertimbangan kemudahan untuk mendapatkan bahan baku yang dapat mencapai nilai di atas agar dosis paparan lebih rendah dari 0,25 mR/Jam,sesuai SK Bapeten No.11/Ka-BAPETEN/VI-99 perisai beton dibuat menjadi tebal 1,5 m
PENGARUH GANGGUAN LISTRIK TERHADAP OPERASI RSG-GAS TERAS 61 Teguh Sulistyo
Jurnal Perangkat Nuklir Vol 1, No 2 (2007): Nopember 2007
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1613.785 KB)

Abstract

THE INFLUENCE OF ELECTRIC FAILURE TO THE OPERATION OF RSG-GAS CORE 61. The system of RSG-GAS electricity is designed for supplying the various of electrics loads, voltages and safety classification of components. The electrics resource were supplied by PLN, emergency gensets and batteries. The failure of main electricity supply PLN is detected by emergency bus bars system BNAIBNBIBNC through the Main Control Room (MCR) monitoring system. This failure has an impact on the primary coolant system operation, secondary coolant system, emergency power supplies BRV 10/20130. It the PLN electric supply failed during reactor operation, the reactor will scram and automatically shutdown to fulfilled the reactor safety criterionPENGARUH GANGGUAN LISTRIK TERHADAP OPERASI RSG-GAS TERAS KE 61. Sistem kelistrikan RSG-GAS dirancang untuk mampu memasok berbagai jenis be ban listrik, jenis tegangan dan klasifikasi keselamatan. Sumber daya listrik yang memasok kebutuhan listrik RSG-GAS disuplai dari tiga jenis sumber yaitu daya listrik utama PLN, daya Iistrik darurat genset dan baterai. Kegagalan suplai daya listrik utama PLN yang terjadi pada operasi RSG-GAS teras ke 61 dideteksi oleh sistem busbar darurat BNAIBNB/BNC melalui RKU yang dimonitor oleh sistem keselamatan reaktor. Gangguan terhadap suplai daya listrik utama tersebut dapat berpengaruh terhadap operasi sistem pendingin primer, sistem pendingin sekunder, sistem purifikasi dan sistem penyedia daya darurat BRVIO/20/30 dan jika gangguan tersebut terjadi pada saat reaktor sedang beroperasi dapat mengakibatkan reaktor scram dan shutdown secara otomatis sehingga kriteria keselamatan dipenuhi
STUDI TENTANG DAYA REAKTIF SISTEM DISTRIBUSI JALUR B RSG-GAS Yan Bony Marsahala
Jurnal Perangkat Nuklir Vol 4, No 7 (2010): Mei 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (769.487 KB)

Abstract

STUDY FOR REACTIVE POWER ON DISTRIBUTION SYSTEM LINE B RSG-GAS. Study for reactive power on distribution system line B RSG-GA is already done. The study intended to evaluate how much inductive load need the reactive power (positive), how much power factor, and what will be done to increase the power factor. The reactive power is the losses power, can't be changed into energy, but it is need for transmission process and it is cause the energy losses. The loads on distribution system line B consist of induction motors which are used for primary cooling system and secondary cooling system, lift, blower on cooling tower, and air condition system. Due to the motors using, the power factor are falling down to low. By the calculation results give that the inductive loads on distribution line Bare 850 KVA and these loads caused the low power factor 0.80. If we want to increase the power factor up to 0, 95, it is need to install the reactive loads likes capacitor bank 250 KVAR. STUDI TENTANG DAYA REAKTIF PADA SISTEM DISTRIBUSI JALUR B RSG-GAS.Telah dilakukan studi ten tang daya reaktif pada sistem distribusi jalur B. Tujuan kajian adalah untuk mengetahui berapa besar beban induktif yang membutuhkan daya reaktif (positip) yang dilayaninya, berapa faktor daya, dan bagaimana cara menaikkan faktor daya tersebut. Daya reaktif itu merupakan daya tidak berguna, tidak dapat dirubah menjadi tenaga, namun diperlukan untuk proses transmisi dan ia akan menyebabkan pemborosan energi. Beban terpasang pada sistem distribusi jalur B terdiri atas motor-motor induksi yang digunakan pada sistem pendingin primer dan sistem pendingin sekunder, peralatan angkat (lift), blower pada menara pendingin, dan sistem pengkondisian udara. Karena penggunaan motor tersebut, maka faktor daya menjadi rendah. Dari hasil perhitungan diperoleh bahwa pada sistem distribusi jalur B terdapat 850,40 KVA beban terpasang induktif, dan beban ini menyebabkan faktor daya rendah pada kisaran harga 0,80. Bila diinginkan menaikkan faktor daya ke tingkat 0.95 maka diperlukan pemasangan beban reaktif (negatip) berupa kapasitor 250 KVAR.  
TINJAUAN KEAMANAN DAN KESELAMATAN DALAM PEMANFAATAN PERALATAN RENOGRAF TERPADU Joko Sumanto; Riswal Nafi Siregar; Abdul Jalil; Sigit Bachtiar
Jurnal Perangkat Nuklir Vol 10, No 2 (2016): Nopember 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (209.227 KB)

Abstract

TINJAUAN KEAMANAN DAN KESELAMATAN DALAM PEMANFAATAN PERALATAN RENOGRAF TERPADU. Setiap pemanfaatan peralatan perlu adanya kepastian bahwa peralatan aman untuk dioperasikan dan terjaga keselamatan bagi pengguna. Tinjauan keamanan dan keselamatan dalam pemanfaatan peralatan renograf terpadu dilakukan untuk mengetahu potensi bahaya dan penanggulangannya. Metoda yang digunakan adalah mengidentifikasi potensi bahaya pada sistem elektronik,  mekanik dan pemanfaatan bahan radioaktif, kemudian menentukan cara penanggulangannya.  Hasil tinjauan terlihat adanya beberapa potensi bahaya yang dapat menimbulkan kecelakaan, cedera pada pengguna bahkan masyarakat umum. Potensi bahaya tersebut dapat dieliminir dengan pemenuhan persyaratan perekayasaan, ketaatan terhadap standar produk, ketaatan terhadap prosedur dan kepatuhan terhadap peraturan dalam pemanfaatan bahan radioaktif
PEREKAYASAAN SISTEM PENCITRAAN MATERIAL DI DALAM REAKTOR PETROKIMIA DENGAN TEKNIK SERAPAN SINAR GAMMA Rony Djokorayono; Indarzah Masbatin Putra; Usep Setia Gunawan
Jurnal Perangkat Nuklir Vol 7, No 1 (2013): Juni 2013
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (328.724 KB)

Abstract

Formation material contained in petrochemical reactor composed of ethylene gas, hydrogen gas and diluent, gas once it is processed at a pressure of 32 bar and a temperature of between 60 º C to 100 º C will produce hydrocarbons. The hydrocarbons die in the form of slurry with a density of between 600 gr/dm3 to 1200 gr/dm3, In the uncontrolled process the hydrocarbons will clot and causing reactor operation stopped because clogged by the clot material. In order the material not to clot, it required imaging detection system that describes the condition of the material in the reactor. Nuclear aplication method to describe the condition of the material in the reactor is simply by gluing several gamma detector outside the walls of the reactor and placing a 137Cs gamma sources amid type reactor process. It has been designed a prototype imaging system with the material in the petrochemical reactor gamma ray absorption technique composed of 137Cs gamma radiation source which is placed in the middle of the reactor, while the gamma radiation that comes out of the gamma source detected by a detector located outside the vessel surrounding the process. There are 12 gamma detectors and the gamma radiation intensity received is proportional to the fluctuation of the material contained within the reactor process. The results of measurements of the twelve detectors are processed by computer to be its dynamic state information material in the reactor process, while the profile monitor display measurement results in the form of two-dimensional topography. PEREKAYASAAN SISTEM PENCITRAAN MATERIAL DI DALAM REAKTOR PETROKIMIA DENGAN TEKNIK SERAPAN SINAR GAMMA, Formasi material yang terdapat di dalam reaktor petrokimia terdiri dari gas ethylene, gas hidrogen dan gas diluent, setelah diproses pada tekanan 32 bar dan temperatur antara 60ºC sampai 100ºC membentuk senyawa hidrokarbon. Senyawa hidrokarbon yang terbentuk berupa slurry dengan densitas antara 600 gr/dm3 sampai 1200 gr/dm3, bila hasil prosesnya tidak terkendali maka senyawa hidrokarbon yang terbentuk akan menggumpal, serta menyebabkan operasi reaktor terhenti karena tersumbat oleh material yang menggumpal. Agar material tidak sampai menggumpal diperlukan sistem deteksi pencitraan yang menggambarkan kondisi material di dalam reaktor. Metoda teknik nuklir dapat menggambarkan kondisi material di dalam reaktor hanya dengan menempelkan beberapa detektor gamma di luar dinding reaktor serta menempatkan sebuah sumber gamma di tengah reaktor. Telah dirancang prototip sistem pencitraan material di dalam reaktor petrokimia dengan teknik serapan sinar gamma yang tersusun dari sumber radiasi gamma 137Cs yang ditempatkan di tengah reaktor. Pancaran radiasi gamma dari sumber gamma dideteksi oleh detektor yang berada disekeliling luar bejana proses, yang berjumlah 12 unit detektor gamma. Intensitas radiasi gamma yang diterima akan sebanding dengan fluktuasi material yang terdapat di dalam reaktor. Hasil pengukuran dari ke duabelas detektor, oleh komputer akan diolah untuk memberikan informasi dinamis keadaan material di dalam reaktor dengan profil tampilan monitor hasil pengukuran berbentuk topografi dua dimensi.
DESAIN PERANGKAT LUNAK DAN PEMODELAN SISTEM IRADIATOR SERBAGUNA Ahmad Rifai; M. Ikhsan Shobary; Gunarwan Prayitno
Jurnal Perangkat Nuklir Vol 4, No 8 (2010): Nopember 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (974.296 KB)

Abstract

SOFTWARE DESIGN AND MODELLING OF A MUL T/PURPOSE IRRADIA TOR SYSTEM. Software design and simulation model for a multi-purpose irradiator has been done. The studied irradiator consits of 19 carriers which move along a defined irradiation path where 9 stoppers are also located. These stoppers are used to control the movement of the carriers. Commands are sent from the stoppers in order to move a carrier along the irradiation path or to stop its movement. Mathematical model based on state machine method is applied for simulating the carriers' movement along the irradiation path. Based on this mathematical model, an algorithm is made and its corresponding interactive computer program will be developed using the standard graphical interface  DESAIN PERANGKAT LUNAK DAN PEMODELAN SISTEM IRADIATOR SERBAGUNA Dilakukan desain perangkat lunak dan model simulasi sistem iradiator serbaguna. Sistem iradiator yang diteliti memiliki 19 carrier yang berjalan pada lintasan medan iradiasi di mana terdapat 9 stopper. Stopper ini berfungsi untuk mengendalikan gerakan seluruh carrier. Pada stopper terdapat mekamisme untuk memerintahkan carrier bergerak sepanjang segmen lintasan atau tetap diam. Metode state machine dipergunakan dalam pembuatan model matematis untuk menirukan mekanisme gerakan carrier pada lintasannya. Berdasarkan model ini maka akan dibangun algoritma dan kemudian perangkat lunak interaktif yang menggunakan antarmuka grafis

Page 7 of 11 | Total Record : 104