The Design of Tachometer Contact and Non-Contact Using Microcontroller Padang Tunggal, Tatiya; Anggi Kirana, Lailicia; Zuhri Arfianto, Afif; T.Helmy, Elsayed; Waseel, Farhad
Journal of Robotics and Control (JRC) Vol 1, No 3 (2020): May
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1315

Abstract

Calibration is required for various kinds of tools from kitchen tools such as stirrers or mixers to medical tools such as temperature calibration, ECG, blood pressure, and other instrumentation tools to be according to the required standards. In medical devices, a digital tachometer has been used as a calibration support device to measure the speed of objects that rotate in RPM on the centrifuge. Some medical devices are calibrated in km/hour, for example, the ergo cycle and treadmill. Two different devices or a conversion from RPM to km/hour are required. The research aimed to design a measurement device that performed calibration of devices with different units, namely tachometer that can be used to measure speed in RPM and km/hr. Based on the research objective, a tool was made to measure the motor's rotational speed using the E18-D80NK sensor, microcontroller, and LCD without touching the object being measured.
The Design of X-Ray Film Reader with Film Presence Detector Padang Tunggal, Tatiya; Arrosyid, Muhtadin; De Brito Silva, Gabriel; Maseleno, Andino; tanane, Omar
Journal of Robotics and Control (JRC) Vol 2, No 2 (2021): March (Forthcoming Issue)
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

X-Ray viewer is a tool for observing the results of X-Ray films using ray lighting. It aims to get clearer readings of X-Ray films by radiographers and doctors. X-Ray viewers in hospitals generally cannot be carried anywhere because they use fluorescent lamps as a source of radiation and use 220 Volt AC voltage directly. So that its use is less effective and efficient because it must be connected directly to a 220 Volt AC power source and requires large power. In this regard the author wants to design an X-Ray viewer tool that can be used to read the results of X-Ray films clearly and is portable so that the device can be used anywhere because it uses a battery as a voltage source and is equipped with a presence detection sensor film in order to save energy so that the use of tools is more effective and efficient.
Prototype of Hand Dryer with Ultraviolet Light Using ATMega8 Padang Tunggal, Tatiya; Wahyu Apriandi, Ahmad; Eko Poetro, Joessianto; T.Helmy, Elsayed; Waseel, Farhad
Journal of Robotics and Control (JRC) Vol 1, No 1 (2020): January
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1102

Abstract

In everyday life, particularly in hospitals, people typically use cloth or tissue to dry our hands. It seems less practical, effective and hygienic. In addition, some restaurants still use cloth or tissue as well. To overcome this problem, several hospitals and restaurants have provided hand dryers. It can dry hands but cannot eliminate germs or bacteria. It is necessary to create a hand dryer equipped with a sterilizer. This work, therefore, created a hand dryer that can simultaneously dry and sterilize hands that worked automatically using the ATMega8 microcontroller. The tool was designed by using an infrared sensor to detect hands, and an ATMEGA8 microcontroller to read and process the sensors to activate UV and heating. The results found that the tool equipped with UV and heating can dry hands while eliminating bacteria and germs.
The Design of Digital Heart Rate Meter Using Microcontroller Padang Tunggal, Tatiya; Asta Juliani, Shela; Agus Widodo, Hendro; Andri Atmoko, Rachmad; Thanh Nguyen, Phong
Journal of Robotics and Control (JRC) Vol 1, No 5 (2020): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1529

Abstract

Cardiac tests generally use an electrocardiograph, the results of which are used by medical teams to diagnose heart conditions. Individual ECG examination is held in a health care institution so that it cannot be held independently, considering the high costs and the need for analysis by a specialist.  It is, therefore, necessary to have a functional and portable device to detect heart rate. The heart rate measuring device, equipped with a finger sensor, was designed for adults. The 15-second measurement interval showed the heart rate in one minute and the results were shown on an LCD. The minimum system circuit used ATMega 16.
Gas Pressure Measurement Device and Medical Vacuum Design Padang Tunggal, Tatiya; Sanjaya, Alfana; Agus Widodo, Hendro; Kunal, Kunal; Thanh Nguyen, Phong
Journal of Robotics and Control (JRC) Vol 1, No 2 (2020): March
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1208

Abstract

Two methods are used in a digital pressure meter available in the market, namely positive pressure, and negative pressure. The positive one is used to measure the air pressure on a sphygmomanometer and medical gas pressure at an outlet in the treatment room so that operators can easily check medical gas pressure for the safety of the patient, or they can routinely check to find out how much pressure of the medical gas. Based on the background, the research aimed to design a digital pressure meter equipped with a medical gas measurement mode so that the device can be used to calibrate the sphygmomanometer, suction pump, and measure the medical gas pressure available at the medical gas outlet in each treatment room.