Claim Missing Document
Check
Articles

Found 6 Documents
Search

Studi Koordinasi Pengaman Motor Arus Bolak-Balik Sari Novalianda; Sri Indah Rezkika; Susilawati Susilawati; Wahyu Adrian
Jurnal VORTEKS Vol. 1 No. 1 (2020): Oktober 2020
Publisher : Program Studi Teknik mesin, Fakultas Teknik, Universitas Al Azhar Medan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54123/vorteks.v1i1.11

Abstract

Sejalan dengan perkembangan teknologi dalam bidang sistem tenaga listrik dan penggunaan mesin mesin listrik sebagai penggerak industri. Motor arus bolak balik (AC) berperan penting dalam dunia industri sebagian besar penggerak yang terdapat didalam pabrik menggunakan motor – motor listrik tersebut, baik dengan supply tiga fasa maupun satu fasa. Berdasarkan hasil penelitian yang telah dilakukan mengenai studi koordinasi pengaman motor arus bolak balik maka diperoleh setting rele untuk beban lebih sebesar 0.08 dari arus nominal dan setting waktu 20 detik, setting rele untuk arus lebih sebesar 0.58 dari arus nominal dan setting waktu 0.1 detik, setting rele untuk tegangan lebih sebesar 0.7 dari tegangan nominal, setting arus untuk rele gangguan tanah 5A sampai 20A dengan setting waktu 1 time dial, setting rele panas lebih untuk CB pada suhu 171.95 oC dan setting sinyal alarm 162.9 oC. Untuk menjaga kehandalan dari sistem pengaman maka perlu digunakan rating dan setting arus serta waktu yang tepat pada rele pengaman. Hal ini perlu diperhatikan karena jika menggunakan setting yang keliru akan mengakibatkan arus gangguan yang besar timbul melewati motor dimana akan mengakibatkan kerusakan motor.
Studi Analisa Gangguan Hubung Singkat Dengan Menggunakan Metode MVAhs (Hubung Singkat) Edy Saputra; Susilawati Susilawati; Muhammad Adam; Abdul Munir Dalimunthe
-
Publisher : RELE (Rekayasa Elektrikal dan Energi) : Jurnal Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (700.453 KB) | DOI: 10.30596/rele.v3i1.5234

Abstract

Abstrak — Metode MVA hubung-singkat (MVAhs) ini, dapat menjadi alternatif dari metode per-unit standart untuk studi hubung singkat. Dimana pada metode ini meniadakan kebutuhan akan besaran dasar, dan pada akhirnya mempresentasikan elemen sistem daya dalam bentuk MVA. Metode ini cukup sederhana dan tidak rentan dengan kesalahan yang tidak dikehendaki. Pada rangkaiannya terdiri dari 3 komponen yaitu, komponen urutan positif, komponen urutan negatif dan komponen urutan nol. Untuk memperoleh titik gangguan MVA hubung-singkat total dari proses penggabungan nilai-nilai setiap komponen. Didasari antara satu komponen dengan komponen yang lainnya, masing-masing yaitu : seri, paralel dan delta wye. Selanjutnya mencari MVAhs dengan cara penggabungan komponen-komponen yang ada pada urutan positif, negatif dan nol dengan menghubungkannya pada hubungan seri, paralel dan delta-wye. Demikian seterusnya, hingga diperoleh satu MVAhs urutan dengan menggabungkan MVAhs urutan dengan salah satu hubungan, akan diperoleh MVAhs total sistem, untuk suatu titik gangguan tertentu yang ditinjau. Maka nilai arus hubung-singkat (Ihs) = 0,338 KA.Kata kunci :  Metode MVA hubung-singkat (MVAhs)Abstract — The short-circuit MVA (MVAhs) method can be an alternative to the standard per-unit method for short circuit studies. Where in this method eliminates the need for basic quantities, and in the end presents the power system elements in the form of MVA. This method is quite simple and not prone to unwanted errors. The circuit consists of 3 components, namely, a positive sequence component, a negative sequence component and a zero sequence component. To obtain the total short-circuit MVA fault points from the process of combining the values of each component. Based on one component with other components, respectively, namely: series, parallel and delta wye. Furthermore, looking for MVAhs by combining existing components in positive, negative and zero sequences by connecting them in series, parallel and delta-wye relationships. And so on, until one sequence MVAhs is obtained by combining the sequence MVAhs with one of the relationships, we obtain the total system MVAhs, for a particular fault point under review. Then the short-circuit current (Ihs) = 0.338 KA.Keywords :     Short-circuit MVA (MVAhs) method
Focus Group Discussion Kualitas Air Danau Toba dalam Penentuan Status Trofik Danau Toba Nita Marikena; Susilawati; Yuli Setiawannie
ABDIKAN: Jurnal Pengabdian Masyarakat Bidang Sains dan Teknologi Vol. 1 No. 3 (2022): Agustus 2022
Publisher : Yayasan Literasi Sains Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55123/abdikan.v1i3.814

Abstract

Lake Toba is a tecto-volcanic lake located in the province of North Sumatra, Indonesia. This lake is the largest lake in Indonesia and Southeast Asia (disbudpar, 2019). Lake Toba has ecotourism, namely Leuser National Park and Forest Area with Special Purpose Aek Nauli, Kawasan Strategi Pariwisata Nasional (KSPN)/Kawasan Pengembangan Pariwisata Nasional (KKPN), namely Lake Toba and its surroundings, and Geopark consisting of Toba Caldera Geopark. This is what makes Lake Toba a tourism potential and a direction of development that needs attention. Currently, the Lake Toba Water Quality Standard is set to Class One as contained in the Governor of North Sumatra Regulation Number 1 of 2009 and the trophic status of Lake Toba is Oligotrophic as contained in the Decree of the Governor of North Sumatra Number 188.44/209/KPTS/2017. The determination of the water quality standard of Lake Toba to be Class One as contained in the Governor of North Sumatra Regulation Number 1 of 2009 and the trophic status of Lake Toba is Oligotrophic as contained in the Decree of the Governor of North Sumatra Number 188.44/209/KPTS/2017 currently does not meet. The purpose of this Focus Group Discussion (FGD) is to get input from FGD participants regarding the water quality and trophic status of Lake Toba. The method implemented is in the form of discussion that discusses the quality of water in Lake Toba. Based on the results of the Focus Group Discussion (FGD), the water quality of Lake Toba leads to the Class Two quality standard and the Trophic Status of Lake Toba leads to Mesotrophs. This is influenced by human activities around the Lake Toba area and natural factors. The impact of decreasing water quality of Lake Toba will be increasingly influenced by the determination of Lake Toba as a Kawasan Strategi Pariwisata Nasional super prioritas. The decline in the water quality of Lake Toba can be managed with the cooperation of all parties, namely the community, businessmen and the government, such as the use of technology, environmental conservation, compliance with permits and others.  
Peningkatan Kemampuan Kognitif Melalui Permainan Media Kartu Angka Pada Kelompok A Di TK Tunas Melati Merauke Dewi Sulistyowati; Kartini Marzuki; Susilawati Susilawati
Jurnal Profesi Kependidikan Vol 3, No 2 OKT (2022)
Publisher : Jurnal Profesi Kependidikan

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pendidikan anak usia dini di TK Tunas Melati untuk pembelajaran kognitif khususnya berhitung kurang. Penelitian ini merupakan penelitian tindakan kelas dengan menggunakan kartu angka buatan guru. Subyek penelitian adalah peserta didik TK Tunas Melati Merauke yang berjumlah 10 peserta didik. Objek dalam penelitian ini yaitu kemampuan kognitif, teknik pengumpulan data dalam penelitian ini yaitu observasi dan dokumentasi, instrumen penelitian yang digunakan berupa panduan observasi teknik analisis data. Hasil penelitian menunjukkan bahwa penerapan dengan praktik langsung dalam kegiatan main menggunakan kartu angka, lebih menarik dan diminati anak di TK Tunas Melati Merauke dengan mencapai keberhasilan berupa peningkatan di setiap pertemuan.Kata Kunci : Kognitif, Media Kartu Angka
Evaluasi Kinerja Modul Praktikum Pengkonversi Sinyal Analog ke Sinyal Digital Resolusi 8 Bit Panangian Mahadi Sihombing; Ridho Akbar Pratama; Indah Vusvita Sari; Dona Tiara Lubis; Susilawati; Sari Novalianda
JURNAL INFORMATIKA DAN PERANCANGAN SISTEM (JIPS) Vol 4 No 2 (2022): Volume 4, No 2: Mei 2022
Publisher : Prodi Teknik Informatika (S1) Institut Teknologi dan Bisnis Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (405.736 KB)

Abstract

The level of accuracy of an integrated circuit (IC) in converting signals is very necessary to achieve good system performance. One of IC device that is often used as analog to digital converter (ADC) is the IC ADC0804. This study aims to evaluate the work of a practicum module for converting analog signals to digital signals, namely the ETEK ACS-3000-07 Module. The module uses the IC ADC0804 to convert analog signals to digital signals. Two methods were used to test the performance of the module, namely the simulation method and the calculation method. Furthermore, the mean error and standard deviation methods are used to analyze the data that has been obtained. Based on the results of the analysis, it is known that the ETEK ACS-3000-07 Module still has sufficient performance in converting analog signals into digital signals because it has a mean error 0.36 and a standard deviation 0.48.
Studi Koordinasi Pengaman Motor Arus Bolak-Balik Sari Novalianda; Sri Indah Rezkika; Susilawati Susilawati; Wahyu Adrian
Jurnal VORTEKS Vol. 1 No. 1 (2020): Oktober 2020
Publisher : Program Studi Teknik mesin, Fakultas Teknik, Universitas Al Azhar Medan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54123/vorteks.v1i1.11

Abstract

Sejalan dengan perkembangan teknologi dalam bidang sistem tenaga listrik dan penggunaan mesin mesin listrik sebagai penggerak industri. Motor arus bolak balik (AC) berperan penting dalam dunia industri sebagian besar penggerak yang terdapat didalam pabrik menggunakan motor – motor listrik tersebut, baik dengan supply tiga fasa maupun satu fasa. Berdasarkan hasil penelitian yang telah dilakukan mengenai studi koordinasi pengaman motor arus bolak balik maka diperoleh setting rele untuk beban lebih sebesar 0.08 dari arus nominal dan setting waktu 20 detik, setting rele untuk arus lebih sebesar 0.58 dari arus nominal dan setting waktu 0.1 detik, setting rele untuk tegangan lebih sebesar 0.7 dari tegangan nominal, setting arus untuk rele gangguan tanah 5A sampai 20A dengan setting waktu 1 time dial, setting rele panas lebih untuk CB pada suhu 171.95 oC dan setting sinyal alarm 162.9 oC. Untuk menjaga kehandalan dari sistem pengaman maka perlu digunakan rating dan setting arus serta waktu yang tepat pada rele pengaman. Hal ini perlu diperhatikan karena jika menggunakan setting yang keliru akan mengakibatkan arus gangguan yang besar timbul melewati motor dimana akan mengakibatkan kerusakan motor.