Rohmadi Rohmadi
C-Tech Labs Edwar Technology

Published : 4 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 4 Documents
Search

Respiration Monitoring System of Lung Phantom Using Magnetic Sensor Imamul Muttakin; David Abraham; Rocky Alfanz; Rohmadi Rohmadi
Bulletin of Electrical Engineering and Informatics Vol 7, No 1: March 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (271.042 KB) | DOI: 10.11591/eei.v7i1.711

Abstract

Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.
Respiration Monitoring System of Lung Phantom Using Magnetic Sensor Imamul Muttakin; David Abraham; Rocky Alfanz; Rohmadi Rohmadi
Bulletin of Electrical Engineering and Informatics Vol 7, No 1: March 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (271.042 KB) | DOI: 10.11591/eei.v7i1.711

Abstract

Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.
Respiration Monitoring System of Lung Phantom Using Magnetic Sensor Imamul Muttakin; David Abraham; Rocky Alfanz; Rohmadi Rohmadi
Bulletin of Electrical Engineering and Informatics Vol 7, No 1: March 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (271.042 KB) | DOI: 10.11591/eei.v7i1.711

Abstract

Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.
Electrical Tomography Sensor Modelling for Detection of Fuel Proportion in Vessel Rian Fahrizal; Jaga Sobar Julianto; Alief Maulana; Rocky Alfanz; Ceri Ahendyarti; Rohmadi Rohmadi; Imamul Muttakin
Jurnal Ilmiah Teknik Elektro Komputer dan Informatika Vol 9, No 2 (2023): June
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26555/jiteki.v9i2.26304

Abstract

Electrical capacitance volume tomography (ECVT) is a method for determining the volumetric distribution of dielectric permittivity using the capacitance measurement principle. The determination of volumetric distribution of dielectric permittivity is important to regulate a process in which quantity of materials is a decisive parameter such as in industrial setting or vehicle sub-system. ECVT is a relatively fast and non-radiating method to observe spatio-temporal phenomena inside a process, making it a valuable technique. Sensor modelling and image reconstruction study are essentials in designing a suitable imaging system based on measurements from plurality of electrodes providing higher degree of information being observed. This research conducts sensor modelling with varying fuel objects in the interior of a cylindrical vessel. The capacitance value was simulated between a combination of eight electrodes mounted encapsulating the tube. Each measured electrode was given an excitation voltage as a source of an electrostatic field, which interacts with the object’s presence. The objects in this study are benzene, kerosene, and diesel fuel, along with reference dielectric values of water and air. Image reconstruction used the linear back projection (LBP) method. Matrix operations between sensor’s pre-defined sensitivity and capacitance values produce data that can be plotted into an image estimating the true distribution of objects. Capacitance values from modelling are proportional to the actual object’s permittivity. The reconstruction provides qualitative information on the proportion of fuel in the vessel based on the capacitance value. Images have distinct values according to the presence of different objects under investigation. The research contribution is a proof of concept in using capacitance tomography to detect different fuels inside an enclosed tank at modelling stage. In addition, this study serves as a guideline for implementing a non-invasive and non-intrusive system for determining proportions of materials of interests inside a certain setup.