Studi Kinerja Gedung Empat Tingkat Terhadap Beban Gempa Dengan Metode Statik Pushover Muhammad Ridho Saputra; Fikri Alami; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 8, No 1 (2020): Edisi Maret 2020
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstrakRumah sakit merupakan salah satu fasilitas yang termasuk bangunan penting kategori IV sehingga dibutuhkan perencanaan struktur tahan gempa dimana bangunan harus tetap berdiri setelah diberikan beban gempa rencana. Analisis pushover merupakan salah satu metode yang digunakan untuk menganalisis beban gempa guna mengetahui perilaku keruntuhan struktur.Penelitian ini bertujuan untuk mengetahui dan menganalisis level kinerja struktur, gaya geser dasar maksimum yang ditahan struktur, pola keruntuhan dan tingkat daktilitas struktur akibat beban gempa. Berdasarkan hasil analisis, didapatkan nilai target displacement dengan metode FEMA-356 sebesar 251,6mm untuk arah-x dan 210,6 mm arah-y sedangkan dengan metode ATC-40 didapatkan nilai 322,027mm untuk arah-x dan 229,491mm untuk arah-y. Level kinerja yang dihasilkan dari kedua metode tersebut adalah damage control dimana resiko korban jiwa manusia sangat kecil, kerusakan yang terjadi masih dapat diperbaiki dan bangunan masih mampu menahan beban gempa rencana yang terjadi. Mekanisme keruntuhan struktur menunjukan mekanisme strong column weak beam sehingga struktur bangunan tersebut relatifaman selama terkena beban gempa direncanakan.Tingkat daktilitas struktur bangunan berdasarkan SNI 1726:2002 adalah daktail parsial dengan nilai R aktual 4,07. Kata kunci: pushover, damage control, daktilitas.AbstractThe hospital is one of the public facilities that is included in an important category IV building so that earthquake resistant structure design is needed where the building must remain standing after being given the burden of the earthquake design. Pushover analysis is one of the methods used to analyze earthquake loads in order to determine the structural collapse behavior of earthquake loads. The purpose of this study is to determine and analyze the level of structural performance, the maximum base shear force held by the structure, the collapse pattern and the level of structural ductility due to earthquake loads. Based on the analysis results, the target displacement value obtained by the FEMA-356 was 251.6mm for the x-axis and 210.6mm for the y-axis while the ATC-40 obtained a value of 322.027mm for the x-axis and 229.491mm for the y-axis The level of performance produced by the two methods was damage control where the risk of human casualties was very small, the damage that occurs can still be repaired and the building is still able to withstand the burden of the designed earthquake. The structure collapse mechanism has strong column weak beam mechanism so that the structure of the building is relatively safe during the earthquake load. The ductility level of building based on SNI 1726:2002 was a partial ductile with the actual reduction factor, R was 4.07. Keywords: pushover analysis, damage control, ductility. AbstrakRumah sakit merupakan salah satu fasilitas yang termasuk bangunan penting kategori IV sehingga dibutuhkan perencanaan struktur tahan gempa dimana bangunan harus tetap berdiri setelah diberikan beban gempa rencana. Analisis pushover merupakan salah satu metode yang digunakan untuk menganalisis beban gempa guna mengetahui perilaku keruntuhan struktur.Penelitian ini bertujuan untuk mengetahui dan menganalisis level kinerja struktur, gaya geser dasar maksimum yang ditahan struktur, pola keruntuhan dan tingkat daktilitas struktur akibat beban gempa. Berdasarkan hasil analisis, didapatkan nilai target displacement dengan metode FEMA-356 sebesar 251,6mm untuk arah-x dan 210,6 mm arah-y sedangkan dengan metode ATC-40 didapatkan nilai 322,027mm untuk arah-x dan 229,491mm untuk arah-y. Level kinerja yang dihasilkan dari kedua metode tersebut adalah damage control dimana resiko korban jiwa manusia sangat kecil, kerusakan yang terjadi masih dapat diperbaiki dan bangunan masih mampu menahan beban gempa rencana yang terjadi. Mekanisme keruntuhan struktur menunjukan mekanisme strong column weak beam sehingga struktur bangunan tersebut relatifaman selama terkena beban gempa direncanakan.Tingkat daktilitas struktur bangunan berdasarkan SNI 1726:2002 adalah daktail parsial dengan nilai R aktual 4,07. Kata kunci: pushover, damage control, daktilitas.