Claim Missing Document
Check
Articles

PERBANDINGAN KUAT TEKAN BETON RINGAN DENGAN METODA RANCANG-CAMPUR ACI DAN DREUX-CORRISE Ratna Widyawati
Rekayasa : Jurnal Ilmiah Fakultas Teknik Universitas Lampung Vol 15, No 2 (2011): Edisi Agustus Tahun 2011
Publisher : UNIVERSITAS LAMPUNG

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Lightweight concrete is one of solving problems to deficiency or loss that is about the size of the dead load weight of the concrete itself. Generally, lightweight concrete has the same mix-design with normal concrete, except that coarse aggregate in lightweight concrete its density must be reduced. One of the lightweight aggregate that has been produced in bulk is ALWA (Artificial Light Weight Aggregate coarse), which is lightweight aggregate from the burning of clay. Because the aggregate is light, then the aggregate can be used as coarse aggregate in lightweight concrete mixtures for building structures. There are several kinds of lightweight concrete mix design. The purpose of this research is compare of compressive strength of lightweight concrete aggregates ALWA with the ACI Methods and Dreux-Corrise Method. Specimens consist of 15 pieces of concrete cylinders (d = 150 mm, t = 300 mm) for lightweight concrete ALWA with the ACI Method. Treatment of samples was done by soaking and aerated for 7 days. Compressive strength testing performed on specimens aged 28 days. There are 3 specimens for 3 days, 7 days and 14 days for compressive strength, and there are 6 speciments for 28 days compression test. The results showed 28 days compressive strength of Dreux-Corrise Method has increased significantly by 35.36% from 14 days compressive strength. While the concrete compressive strength of 28 days with ACI method only increased by 1.92% from 14 days compressive strength. Value of compressive strength at Dreux-Corrise method is higher than the ACI method that is equal to 16.37% in the same targeted of 24.5 MPa.
STUDI KUAT TEKAN BETON RINGAN DENGAN METODA RANCANG-CAMPUR DREUX-CORRISE Ratna Widyawati
Rekayasa : Jurnal Ilmiah Fakultas Teknik Universitas Lampung Vol 15, No 1 (2011): Edisi April Tahun 2011
Publisher : UNIVERSITAS LAMPUNG

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Concrete as a civil building construction materials have a deficiency or loss that is about the size of the dead load weight of the concrete itself. Dead load on the building structure can be minimized by the use of lightweight concrete. To get a lightweight concrete that meets the quality or value of concrete compressive strength, is strongly influenced by the selection of coarse aggregate and mix proportion of concrete used. Concrete is called lightweight concrete if volume weight is 1400-1850 kg/m3 (ACI 213R-79). The purpose of this research is to investigate the values of compressive strength of lightweight concrete aggregates ALWA with the Dreux-Corrise Method. Specimens consist of 15 pieces of concrete cylinders (d = 150 mm, t = 300 mm) for lightweight concrete ALWA with the Dreux-Corrise Method. Treatment of samples was done by soaking and aerated for 7 days. Compressive strength testing performed on specimens aged 28 days. There are 3 specimens for 3 days, 7 days and 14 days for compressive strength, and there are 6 speciments for 28 days compression test. The results showed average for compressive strength are 9,38 MPa; 7,86 MPa ; 13,30 MPa dan 20,59 MPa for 3 days; 7 days; 14 days and 28 days respectively. The average value of the compressive strength obtained from the Dreux-Corrise Method was 20,59 MPa (28 days) lower than targeted of 24,5 MPa.
KERUNTUHAN LENTUR BALOK PADA STRUKTUR JOINT BALOK-KOLOM BETON BERTULANG EKSTERIOR AKIBAT BEBAN SIKLIK Ratna Widyawati
Rekayasa : Jurnal Ilmiah Fakultas Teknik Universitas Lampung Vol 13, No 3 (2009): Edisi Desember Tahun 2009
Publisher : UNIVERSITAS LAMPUNG

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Dasar perencanaan struktur beton bertulang adalah under-reinforced structure atau strukturbertulangan lemah, sehingga apabila terjadi keruntuhan pada struktur tersebut yang terjadi adalahkeruntuhan lentur. Beberapa penelitian mengenai tinjauan keruntuhan lentur pada struktur betonyang mengalami kerusakan akibat beban gempa yang disimulasikan dengan beban siklik telahdilakukan. Salah satu manfaat penelitian ini adalah untuk mengetahui pola keruntuhan lentur padajoint balok-kolom beton bertulang eksterior akibat beban siklik.Benda uji yang digunakan berupa struktur joint balok-kolom beton bertulang eksterior berjumlah 2(dua) buah. Dua buah benda uji dibuat dengan beton normal. Kolom dimensi 250 mm x 250 mm,panjang 1250 mm dan balok dimensi 150 mm x 250 mm, panjang 1100 mm. Tulanganlongitudinal balok 5 D 16 untuk momen negative dan 3 D 16 untuk momen positif dengansengkang P 8-100 mm dan pelat dengan lebar efektif 800 mm dengan tebal 60 mm. Pengujiandilakukan dengan memberikan beban siklik yang merupakan simulasi dari beban gempa padaujung balok.Hasil pengujian menunjukkan, semua benda uji joint balok-kolom beton bertulang eksteriormengalami keruntuhan lentur pada bagian balok. Keruntuhan lentur tersebut diawali dengan retakawal (first crack) pada saat rerata beban positif sebesar 25 kN dan rerata beban negatif –26,25 kN.Pola retakan yang terjadi berupa retak lentur dengan arah tegak lurus sumbu utama balok padapermukaan bagian bawah balok dan permukaan bagian atas pelat. Pola retak yang terjadi adalahretak lentur pada bagian bawah badan balok. Beban pada saat runtuh mencapai 66,67 kN untukrerata beban positif dan –61,79 kN rerata beban negatif. Keruntuhan lentur diawali dengan firstcrack berupa retak lentur pada sisi bawah balok, yang arahnya 90 derajat terhadap sumbu utamabalok merupakan indikasi dari kegagalan lentur.
Evaluasi Bangunan Gedung Rumah Sakit Terhadap Beban Gempa Dengan Menggunakan Metode Statik Ekuivalen Farhan Nurrohmat; Ratna Widyawati; Fikri Alami
Jurnal Rekayasa Sipil dan Desain Vol 8, No 4 (2020): Edisi Desember 2020
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Rumah sakit merupakan bagian integral dari suatu organisasi sosial dan kesehatan dengan fungsi menyediakan pelayanan, penyembuhan penyakit dan pencegahan penyakit kepada masyarakat. Sehingga perlu diteliti untuk mengetahui kekuatan dan kinerja struktur gedung terhadap beban gempa pada gedung Rumah Sakit. Tujuan penelitian ini adalah mengevaluasi kinerja struktur atas Gedung Rumah Sakit terhadap beban gempa statik ekivalen dalam memenuhi persyaratan keamanan struktur berdasarkan SNI:1726-2012. Perhitungan beban gempa menggunakan metode Statik Ekuivalen dengan bantuan program ETABS 2017. Analisis gempa statik ekivalen digunakan untuk mengevaluasi kinerja layan bangunan dan kinerja struktur bangunan. Dari hasil analisis, diperoleh Story drift yang tergolong aman karena tidak melebihi batas simpangan izin sebesar 209 mm dan level kinerja struktur pada peraturan ATC-40 gedung masih dalam keadaan elastis. Balok dan kolom tidak perlu dievaluasi ke tahap Pushover karena nilai DCR kurang dari 2. Balok B1 di Lantai 2-4 memiliki perbedaan antara tulangan lentur dan geser yang dibutuhkan pada analisis dengan tulangan pada eksisting. Kolom lantai 2 K1.5, K1.8, K1.11 memiliki perbedaan antara tulangan lentur yang dibutuhkan pada analisis dengan tulangan pada eksisting. dan untuk tulangan geser kolom dalam kondisi aman. Penulangan pelat lantai pelat Lantai 2 sampai dengan 5 pada daerah tumpuan dan lapangan pelat arah X dan Y aman karena sama dengan hasil eksisting.
Evaluasi dan Perkuatan Struktur Pelat, dan Dinding Geser dengan Glass Fiber Reinforced Polymer (GFRP) Stephanus Martua Turnip; Fikri Alami; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 7, No 1 (2019): Edisi Maret 2019
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The Education hospital building of University of Lampung has been stalled and the construction is abandoned for years. So that, there is concern about the existing strength installed in the field. Therefore, it is necessary to evaluate and to strengthen the structure for increasing the strength and assuring appropriateness of the building. Two methods used in evaluating this building which weredirect survey method in the field and numerical method used the Finite Element Analysis (FEA) program. For strengthening calculations the American Concrete Institute code was applied (ACI 440.2R, 2008). The material for strengthening used Glass Fiber Reinforced Polymer (GFRP). The results showed that the existing concrete compressive strength on all structural elements decreased from the design which was 25 MPa. However, theexisting steel reinforcement tests showed good strength which greater than design strength of 400 Mpa.In strengthening calculation with GFRP type of SEH-51A which has tensility strength of 460 MPa, the material can increase flexural strength of several slabs that requiredfor strengthening. In addition, in the shear wall analysis, it concluded that the existing shear wall were strong enough to withstand the nominal shear forcesdesign that might be occured. Keywords : Structures Evaluation, Strengthening Structures, Glass Fiber Reinforced Polymers, Concrete Slab and Shear Walls.
Studi Kinerja Gedung Empat Tingkat Terhadap Beban Gempa Dengan Metode Statik Pushover Muhammad Ridho Saputra; Fikri Alami; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 8, No 1 (2020): Edisi Maret 2020
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstrakRumah sakit merupakan salah satu fasilitas yang termasuk bangunan penting kategori IV sehingga dibutuhkan perencanaan struktur tahan gempa dimana bangunan harus tetap berdiri setelah diberikan beban gempa rencana. Analisis pushover merupakan salah satu metode yang digunakan untuk menganalisis beban gempa guna mengetahui perilaku keruntuhan struktur.Penelitian ini bertujuan untuk mengetahui dan menganalisis level kinerja struktur, gaya geser dasar maksimum yang ditahan struktur, pola keruntuhan dan tingkat daktilitas struktur akibat beban gempa. Berdasarkan hasil analisis, didapatkan nilai target displacement dengan metode FEMA-356 sebesar 251,6mm untuk arah-x dan 210,6 mm arah-y sedangkan dengan metode ATC-40 didapatkan nilai 322,027mm untuk arah-x dan 229,491mm untuk arah-y. Level kinerja yang dihasilkan dari kedua metode tersebut adalah damage control dimana resiko korban jiwa manusia sangat kecil, kerusakan yang terjadi masih dapat diperbaiki dan bangunan masih mampu menahan beban gempa rencana yang terjadi. Mekanisme keruntuhan struktur menunjukan mekanisme strong column weak beam sehingga struktur bangunan tersebut relatifaman selama terkena beban gempa direncanakan.Tingkat daktilitas struktur bangunan berdasarkan SNI 1726:2002 adalah daktail parsial dengan nilai R aktual 4,07. Kata kunci: pushover, damage control, daktilitas.AbstractThe hospital is one of the public facilities that is included in an important category IV building so that earthquake resistant structure design is needed where the building must remain standing after being given the burden of the earthquake design. Pushover analysis is one of the methods used to analyze earthquake loads in order to determine the structural collapse behavior of earthquake loads. The purpose of this study is to determine and analyze the level of structural performance, the maximum base shear force held by the structure, the collapse pattern and the level of structural ductility due to earthquake loads. Based on the analysis results, the target displacement value obtained by the FEMA-356 was 251.6mm for the x-axis and 210.6mm for the y-axis while the ATC-40 obtained a value of 322.027mm for the x-axis and 229.491mm for the y-axis The level of performance produced by the two methods was damage control where the risk of human casualties was very small, the damage that occurs can still be repaired and the building is still able to withstand the burden of the designed earthquake. The structure collapse mechanism has strong column weak beam mechanism so that the structure of the building is relatively safe during the earthquake load. The ductility level of building based on SNI 1726:2002 was a partial ductile with the actual reduction factor, R was 4.07. Keywords: pushover analysis, damage control, ductility. AbstrakRumah sakit merupakan salah satu fasilitas yang termasuk bangunan penting kategori IV sehingga dibutuhkan perencanaan struktur tahan gempa dimana bangunan harus tetap berdiri setelah diberikan beban gempa rencana. Analisis pushover merupakan salah satu metode yang digunakan untuk menganalisis beban gempa guna mengetahui perilaku keruntuhan struktur.Penelitian ini bertujuan untuk mengetahui dan menganalisis level kinerja struktur, gaya geser dasar maksimum yang ditahan struktur, pola keruntuhan dan tingkat daktilitas struktur akibat beban gempa. Berdasarkan hasil analisis, didapatkan nilai target displacement dengan metode FEMA-356 sebesar 251,6mm untuk arah-x dan 210,6 mm arah-y sedangkan dengan metode ATC-40 didapatkan nilai 322,027mm untuk arah-x dan 229,491mm untuk arah-y. Level kinerja yang dihasilkan dari kedua metode tersebut adalah damage control dimana resiko korban jiwa manusia sangat kecil, kerusakan yang terjadi masih dapat diperbaiki dan bangunan masih mampu menahan beban gempa rencana yang terjadi. Mekanisme keruntuhan struktur menunjukan mekanisme strong column weak beam sehingga struktur bangunan tersebut relatifaman selama terkena beban gempa direncanakan.Tingkat daktilitas struktur bangunan berdasarkan SNI 1726:2002 adalah daktail parsial dengan nilai R aktual 4,07. Kata kunci: pushover, damage control, daktilitas.
Analisis Investasi Rekayasa Proyek Pembangunan RS PTN Universitas Lampung Anissa Putri Ambarwati; Ika Kustiani; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 6, No 4 (2018): Edisi Desember 2018
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The establishment of RS PTN Unila is intended to fulfill social function by provided health services as well as income generating unit. RS PTN Unila is also expected to be a center of collaboration between research and health services. Even though the facility is provided by government of the province of lampung, The study was carried out to examine the viability of the invested. The viability was analyzed through several parameter, named Net Present Value (NPV), Benefit to Cost Ratio (BCR), Internal Rate of Return (IRR), Payback Period (PP).The viability was also analyzed through 9 scenarios. Scenarios were varied base on inflation rate and Bed occupancy rate. The result show that all scenarions was viable. The best scenarions was based on the assumptions of bed occupancy rate 100%, inflation rate of 5 % and discount rate 15% and the source of investment provided by government. Keyword: Feasibility Study , Net Present Value (NPV), Benefit Cost Ratio (BCR), Internal Rate of Return (IRR), Payback Period (PP)
Analisis Desain Gedung Whiz Hotel Metode Sistem Rangka Pemikul Momen Khusus lexono x nadeak; Suyadi Suyadi; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 4, No 3 (2016): Edisi September 2016
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstractSpecial Moment Resisting Frame System(SMRFS) is a system with the highest ductility and that has detail requirements in the calculation of structural reinforcement components of axial, bending and shear of beam and columns elements, as well as provisions regarding the beam column connection that will affect the overall performance building when receiving earthquake load. This study aims to determine the detail requirements of special moment resisting frame system in accordance with SNI 2847-2013 and performance evaluation of structures with pushover analysis. Based on study results, the level of structure performance in accordance with the performance point obtained shows that the values of the displacement target are 0.042 m in x-direction and 0.413 m in y-direction. The value of the performance point also shows that the building is designed in the Immediate Occupancy condition that is while the building receives the earthquake load, it is expected that the structure will not be damaged. Distribution of plastic hinge is appropriate to the expectation that is the strong column and the weak beam because plastic hinge formation begins from the beam element then the column element. From the pushover analysis, it is obtained the value of the actual reduction factors (R) are 8.9 in x-direction and 7.8 in y-direction, while the values of the actual system over strength factor (Ωo) are 4.34 in x-direction and 5.70 in y-direction and the values of actual deflection magnification factor (Rd) are 5.9 in x-direction and 5.2 in y-direction.Keywords : pavement distress types, severity level, PCIAbstrakSistem Rangka Pemikul Momen Khusus (SRPMK) merupakan sistem dengan daktilitas tertinggi dan memiliki persyaratan yang detail dalam perhitungan penulangan komponen struktur aksial, lentur dan geser untuk elemen balok dan kolom, serta ketentuan mengenai hubungan balok kolom yang akan mempengaruhi kinerja bangunan secara keseluruhan ketika menerima beban gempa. Penelitian ini bertujuan untuk mengetahui detail persyaratan sistem rangka pemikul momen khusus sesuai dengan SNI 2847-2013 dan evaluasi kinerja struktur dengan pushover analysis. Berdasarkan hasil studi, level kinerja struktur sesuai dengan titik kinerja yang didapat menunjukkan nilai dari target perpindahan untuk arah x sebesar 0,042 m dan arah y sebesar 0,413 m. Nilai dari titik kinerja juga menunjukkan bahwa bangunan yang di desain berada pada kondisi Immediate Occupancy dimana kondisi gedung saat menerima beban gempa diharapkan struktur tidak akan mengalami kerusakan. Distribusi sendi plastis sesuai yang diharapkan yaitu kolom kuat dan balok lemah karena terbentuknya sendi plastis diawali dari elemen balok terlebih dahulu kemudian diikuti elemen kolom. Dari hasil analisis pushover didapat nilai faktor reduksi gempa (R) aktual arah x sebesar 8,9 dan arah y sebesar 7,8, sedangkan nilai faktor kuat lebih sistem (Ωo) aktual arah x sebesar 4,34 dan arah y sebesar 5,70 dan nilai faktor pembesaran defleksi (Rd) aktual arah x sebesar 5,9 dan arah y sebesar 5,2.Kata kunci : SRPMK, titik kinerja, sendi plastis, analisis pushover
OPTIMALISASI PROFIL BAJA IWF PADA BANGUNAN GUDANG KONSTRUKSI GABLE FRAME BERDASARKAN SNI 1729:2015 Ardini Yuliastri Putri; Bayzoni Bayzoni; Ratna Widyawati
Jurnal Rekayasa Sipil dan Desain Vol 5, No 2 (2017): Edisi Juni 2017
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The increasement and development of economic growth in Indonesia cause increasement of the construction of warehouse to support business expansion. However, there is an opinion about expensive steel prices which is causes the use of the steel its self is not optimum. In this case, there must be a calculation to determine the model of gable frame and the dimension of steel profiles for the warehouse.  In this study, the frame model is limited of four types that have differences in haunch span.  This study also use the Direct Stiffness Method to calculate structural analysis and  SNI 1729: 2015 to calculate section analysis.  From structural and section analysis, obtained weight for each type of frame.  Frame Type 1 has 4.771,89 kg, Frame Type 2 has 3.348,18 kg, Frame Type 3 has 3.682,24 kg and Frame Type 4 has 10.541,1506 kg.  Based on the volume and weight calculation in each frame type, Frame Type 2 has the lowest weight. Hence, this type of portal can be considered as the most optimum portal type. Key word : gable frame construction, SNI 1729: 2015, Direct Stiffness Method
HUBUNGAN FAKTOR – FAKTOR SISTEM MANAJEMEN TERHADAP KELAYAKAN USAHA PETERNAKAN KUCING RAS (CATTERY) DIWILAYAH SURABAYA, SIDOARJO DAN GRESIK MENGGUNAKAN MULTIDIMENSIONAL SCALING (MDS) Ratna Widyawati
Jurnal Ilmiah Fillia Cendekia Vol 5 No 1 (2020): Jurnal Ilmiah Fillia Cendekia
Publisher : Universitas Islam Kadiri

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (491.511 KB) | DOI: 10.32503/fillia.v5i1.939

Abstract

Penelitian ini bertujuan untuk mengetahui perbandingan kelayakan usaha cattery di wilayah Surabaya, sidoarjo dan Gresik dengan melihat faktor- faktor dari sistem manajemen yang mempengaruhi kelayakan suatu usaha cattery. sistem manajemen meliputi perencanaan, sumber daya manusia (SDM), sistem perkandangan dan sistem pemeliharaan. Metode penelitian yang digunakan adalah metode survei. Prosedur pengambilan data dilakukan melalui pengamatan langsung dan wawancara. pengumpulan data dalam penelitian ini menggunakan teknik kuesioner, teknik dokumentasi dan teknik wawancara. masing - masing indikator dari sistem manajemen berupa kuesioner diukur dengan skor antara 1-5 berdasarkan kriteria. Nilai skor dari masing - masing indikator selanjutnya dianalisis untuk mengetahui faktor - faktor apa saja yang menyebabkan kelayakan dari usaha peternakan kucing (cattery) tersebut dengan MDS berdasarkan hasil layak atau tidaknya usaha cattery yang dihitung menggunakan rumus. hasil penelitian ini menunjukkan bahwa ada dua cattery yang dinyatakan layak usahanya yaitu di wilayah Surabaya dan ada dua cattery yang dinyatakan belum layak usahanya yaitu di wilayah Sidoarjo dan Gresik.