Muttaqin Muttaqin
Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah kuala, Banda Aceh

Published : 13 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 13 Documents
Search

IDENTIFIKASI FAKTOR KINERJA KONTRAKTOR YANG PALING BERPENGARUH TERHADAP KEPUASAN STAKEHOLDERS DI DINAS CIPTA KARYA ACEH Mohammad R. Khadafi; Muttaqin Muttaqin; Anita Rauzana
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 2, No 3 (2019): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v2i3.13464

Abstract

In the midst of increasingly fierce competition in the world of today's construction business, every construction company is required to be able to demonstrate the quality of its service so that it can excel in competition. As a company engaged in services/selling services, construction companies must have knowledge of the dimensions of service quality. There are five factors from the dimensions of service quality, namely tangible, reliability, responsiveness, assurance and empathy. If the performance can meet their expectations, the stakeholders will be satisfied and vice versa. This study aims to identify contractor performance factors that most influence stakeholder satisfaction in the Aceh Human Settlements Agency. This study used mixed methods, combining qualitative and quantitative approaches through questionnaires. The respondents are the stakeholders of the project stakeholders at Aceh Human Settlements Agency in 2016, which consists of the Budget User, Proxy of Budget User, Technical Officer (PPTK) and Technical Officer Assistant, which in total amounted to 32 respondents. Data processing methods use validity and reliability tests, while descriptive statistical analysis uses SPSS version 22 software. The results of the study showed that the contractor's performance factors that had the most influence on stakeholder satisfaction in the Aceh Human Settlements Agency were reliability factors with a mean value of 3.714, while the least influential factors were physical evidence factors with a mean value of 3.332
FAKTOR-FAKTOR PENERAPAN KESELAMATAN DAN KESEHATAN KERJA YANG MEMPENGARUHI KINERJA PROYEK KONSTRUKSI GEDUNG DI PROVINSI ACEH Bunial Bunial; Muttaqin Muttaqin; Anita Rauzana
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 1, No 4 (2018): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v1i4.12463

Abstract

PT. Jamsostek stated that in 2012 everyday there are 9 workers who died due to accidents, while total work accident in the same year recorded 103,000 cases. Accidents to these workers will certainly make the productivity of project work decreased, as well as will impact on the poor performance of the project. This study aims to identify the dominant OSH factors applied in the implementation of building construction projects in Aceh Province, and to analyze the relationship and influence between the factors of OSH implementation on the performance of building construction projects in Aceh Province. This study uses qualitative methods through interviews and quantitative through the distribution of questionnaires. The number of research samples obtained by 68 contractor companies. The sampling technique used is purposive sampling. Data processing methods consist of test validity, and reliability, while data analysis consists of descriptive analysis, simple correlation and multiple linear regression. The results showed that the dominant K3 factor applied in the implementation of the building construction project in Aceh Province was a public protection factor with a mean of 4.632. The safety and work competence factors have a good relationship with Spearman coefficient of 0.451 and 0.429, the factors of equipment and work clothes, vehicle lanes, and equipment and machinery have a low correlation with Spearman coefficient of 0.328, 0.386, and 0.243, while fire, and sound, public protection, general, occupational health, and seriousness of the company have a very low relation with Spearman coefficient of 0.077, 0.130, 0.066, 0.107, 0.121, and 0.169 to the performance of building construction projects in Aceh Province. The influence of OSH implementation factors on the performance of building construction project in Aceh Province, which has significant effect is safety factor, equipment and work clothes, vehicle path, equipment and machinery, public protection, general, seriousness of company, and worker competence with tcount greater than ttable and significance value lower than 0.05.
KUAT TEKAN BETON MUTU TINGGI HYBRID DENGAN SUBSTITUSI SEMEN DAN AGREGAT HALUS SERTA PENAMBAHAN NANO MATERIAL BIJIH BESI Nora Usrina; Teuku Budi Aulia; Muttaqin Muttaqin
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 1, No 1 (2018): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v1i1.10368

Abstract

SNI 03-6468-2000 defines a high-quality concrete as a concrete with a compressive strength equal to or larger than 41,4 MPa. To obtain a high strength concrete, increasing the quality of material components is needed. The improvement of concrete quality can be done by addition or substitution processes in the concrete mixture. In this research, the substitution of cement, fine aggregate and coarse aggregate with fly ash coal, palm shells, pozzolan sands and the addition of iron ore nanomaterial as filler (BMT-H) were selected. The purpose of this research is to compare the compressive strength of hybrid high-quality concrete (BMT-H) to normal high-quality concrete (BMT-N). Samples of concrete compressive in a cylindrical shape with diameter 15 cm and height 30 cm were prepared. Concrete compressive strength test was performed on concrete at age of 7 days, 28 days, and 56 days. The results of compressive strength maximum on concrete at age 7 days, 28 days and 56 days are 44,28 MPa; 59,48 MPa and 69,71 MPa, consecutively.