Yayan Tahyan
Pusat Radioisotop dan Radiofarmaka-BATAN

Published : 5 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 5 Documents
Search

PROSES UJI KUALITAS PRODUK Mo-99 HASIL BELAH U-235 DI PUSAT PRODUKSI RADIOISOTOP PERIODE 1995 -1996 Kadarisman, Kadarisman; Komala, Imas; Gunawan, Adang Hardi; Suparman, Ibon; Sayad, M.; Djoharly, Djoharly; Sovilawati, Evi; Ramli, Martalena; Ritonga, Togar M.; Tahyan, Yayan; Hafid, Dadang; Herlina, Herlina; Karyadi, Karyadi; Lestari, Enny; Sarmini, Endang; Mujinah, Mujinah; Kurniasih, Dede
Jurnal Radioisotop dan Radiofarmaka Vol 1, No 2 (1998): JURNAL PRR 1998
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3947.404 KB)

Abstract

ROSES UJI KUALIT AS PRODUK 99Mo HASIL BELAH 235U DI PUSAT PRODUKSI RADIOISOTOP PERIODE 1995 -1996. Telah dilakukan evaluasi kualitas produk 99Mo hasil belah 235U. Konsentrasi radioaktivitas, kemurnian radionuklida, pengotor radionuklida pemancar gamma dan alfa telah dibahas. Sebanyak 44 buah cuplikan produk 99Mo yang diproses dari Januari 1995 sampai dengan Juni 1996 di Pusat Produksi Radioisotop - BATAN, telah diperiksa dan dievaluasi memenuhi persyaratan kualitas sesuai yang ditetapkan oleh Medy-Physics Inc dan layak digunakan untuk pembuatan generator 99Mo - 99mTc. Konsentrasi radioaktivitas produk 99Mo berkisar dari 280 mCi/mL sampai dengan 4500 mCi/mL pada saat kalibrasi. Konsentrasi radioaktivitas total pengotor radionuklida pemancar alfa yang ditetapkan dengan pencacah alfa Eberlin berkisar antara 0,04 x 10-7 µCi/mCi 99Mo sampai dengan 4,55x10-7 µCi/mCi 99Mo, yang menunjukkan semua produk 99Mo yang dianalisis memenuhi persyaratan yang telah ditetapkan, maksimum 1,0 x 10-6 µCi/mCi 99Mo. Demikian juga konsentrasi radioaktivitas pengotor radionuklida pemancar gamma tidak ada yang melampaui persyaratan yang telah ditetapkan, yaitu 131I < 0,05 µCi/mCi 99Mo, 103Ru < 0,05 µCi/mCi 99Mo dan total nuklida pemancar gamma yang lain < 0,1 µCi/mCi 99Mo. Konsentrasi radioaktivitas nuklida pengotor 131I terbesar adalah 0,0125 µCi/mCi 99Mo, untuk 103Ru 0,032 µCi/mCi 99Mo, dan untuk total nuklida lainnya 0,08031 µCi/mCi 99Mo. Nuklida pemancar gamma yang paling dominan mengotori produk 99Mo hasil belah 235U adalah radioiodium yang terdiri dari isotop 133I(dalam 42 batch), 132I(dalam 37 batch) dan isotop 133I (dalam 39 batch). Sedangkan yang paling sedikit adalah nuklida 140Ba dan 132Tc, masing­ masing dalam 1 batch dari jumlah 44 batch. QUALITY CONTROL PROCESS OF 99Mo FISSION PRODUCT IN RADIOISOTOPE PRODUCTION CENTER 1995 - 1996. Quality evaluation of 99Mo fission was carried out. Radioactive concentration, impurities of gamma and alpha emitting radionuclides were investigated. Fourty four batches of 99Mo were processed from January 1995 to June 1996 in Radioisotope Production Center - BATAN, were investigated for the agreement with the quality requirement set out by Medy-Physics Inc. and their suitability for 99mTc generator production. Radioactive concentration of 99Mo solutions were found between 280 mCi/mL to 4500 mCi/mL at calibration time. Radioactive concentration of total alpha emitting impurities were between 0,04 x 10-7 µCi/mCi 99Mo to 4,55 x 10-7 µCi/mCi 99Mo which complied with the impurity limit of 1.0 x 10-6 µCi/mCi 99Mo at calibration time. Radioactive concentration of gamma emitting impurities of all 44 99Mo solutions complied with quality requirements set out by Medy-Physics Inc. i.e. 131I < 0.05 µCi/mCi 99Mo, 103Ru <0.05 µCi/mCi 99Mo and others gamma emitter < 0.1 µCi/mCi 99Mo. The highest radioactive concentartion of impurities observed were 0.0125 µCi 131I/mCi 99Mo, 0.032 µCi 103Ru/mCi 99Mo and other was 0.0803 µCi/mCi 99Mo. Major gamma enitting impurities were radioiodine, i.e: 131I in 42 batches, 132I in 37 batches and 133I in 39 batches, while 140Ba and 132Te were only observed in one batch.
PEMBUATAN RADIOFARMAKA PET 18F_FDG MENGGUNAKAN MODUL SINTESA OTOMATIK Purwoko, Purwoko; Chairuman, Chairuman; Gunawan, Adang Hardi; Tahyan, Yayan; Lestari, Eny; Lestiyowati, Sri Aguswarini; Karyadi, Karyadi; Bagiawati, Sri
Jurnal Radioisotop dan Radiofarmaka Vol 13, No 2 (2010): Jurnal PRR 2010
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKPEMBUATAN RADIOFARMAKA PET 18F_FDG MENGGUNAKAN MODUL SINTESAOTOMATIK.Radiofarmaka 2-(18F)Fluoro-2-deoksi-O-glukosa at au ISF(FOG) adalah radiofarmaka PET(Positron Emission Tomography) yang sangat penting untuk pencitraan lesi tumor. Oengan teknik PETmetabolisme glukosa dalam jaringan tumor di dalam tubuh dapat dibedakan dan diukur secara kuantitatifsehingga digunakan untuk diagnosa tingkat keganasan serta pemantauan pengobatan penyakit tumor ataukanker dalam bidang onkologi kedokteran. Telah dilakukan uji coba produksi 2-(lSF)Floro-2-deoksi-OglukosaISF_ FOG menggunakan perangkat modul sintesa otomatik TRACERlab MX. Perangkat modul inimemberikan kemudahan dalam sintesa rutin radiofarmaka lsF_FOG yang didasarkan pad a reaksi tlorinasinukleofilik terhadap prekursor manosa tritlat dengan katalisator kriptofik. Perolehan yield radiokimia lSF(FOG) mencapai 53,895% (tanpa koreksi waktu peluruhan) dalam waktu 40 men it, produk berupa larutanjernih tak berwarna pH : 6, steril dan bebas pirogen, kadar pengotor kriptofix sangat rendah dan kemurnianradiokimia 99,595 %.Kata kunci: PET, radiofarmaka,PRODUCTION OF PET RADIOPHARMACEUTICAL 18F_FDG USING SYNTHESIZERAUTOMATIC MODUL.Radiopharmaceutical 2-esF)Fluoro-2-0eoxy-O-Glukose or IsF(FOG) is animportant PET (Positron Emission Tomography) radiopharmaceutical for tumour imaging. In the PETtechnique glucose metabolism in tumour tissues can be determined quantitatively and used for diagnosisstaging and monitoring of treatment tumour or cancer disease in medical oncology. The production of 2eSF)Fluoro-2-0eoxy-O-Glucose ISF -FOG using compact automated system module TRACERlab MXhas been carried out. The modular setup of the apparatus permits reliable for routine synthesis ofradiopharmaceuticals lSF -FOG based on kriptofix mediated nucleophilic tluorination to mannose tritlateprecursor. Radiochemical yield of IsF-FOG was 53.895 % (decay time uncorrected) in 40 minutes. Theproduct showed that the colorless and clear solution at pH:6, sterile and pirogen free, kriptofix impuritieswas low and radiochemical purity was 99.595%.Keywords: PET, radiopharmaceutical, FOG
EVALUASI PROSES PRODUKSI RADIOISOTOP Sm-153 DAN SEDIAAN RADIOFARMAKA Sm-153 EDTMP Kadarisman, Kadarisman; Hastini, Sri; Tahyan, Yayan; Abidin, Abidin; Hafid, Dadang; Lestari, Enny
Jurnal Radioisotop dan Radiofarmaka Vol 9 (2006): jurnal PRR 2006
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (65.914 KB)

Abstract

EVALUASI PROSES PRODUKSI RADIOISOTOP Sm-153 DAN SED1AAN RADIOFARMAKA Sm-153 EDTMP. Telah dilakukan percobaan proses produksi radioisotop Sm-153 dan proses penandaan sediaan radiofarmaka Sm-153 EDTMP, yang bertujuan untuk mengevaluasi proses produksi radioisotop Sm-153 dan sediaan radiofarmaka Sm-153 EDTMP di Pusat Radioisotop dan Radiofarmaka, BATAN. Dalam percobaan ini mencakup penyiapan bahan sasaran Sm2O3, pelarutan pasca irradiasi, penetapan konsentrasi radioaktivitas isotop Sm-153, kemurnian radionuklida, proses penandaan senyawa EDTMP, penetapan kemurnian radiokimia dan pH. Dalam percobaan ini diperoleh produk radioisotop Sm-153 dengan radioaktivitas total antara 2845,83 mCi s/d 36963,31 mCi atau dengan konsentrasi radioaktivitas antara 474,30 mCi/ml sampai dengan 6160,55 mCi/ml) berbentuk larutan SmCl3yang masing-masing mempunyai volume 6,0 ml, kandungan samarium 5,76 mg/ml dan dengan kemurnian radionuklida dari produk radioisotop Sm-153 adalah 100 %. Semua produk sediaan radiofarmaka Sm-153 EDTMP memenuhi syarat konsentrasi radioaktivitas, kandungan Sm, kemurnian radiokimia dan pH. Konsentrasi radioaktivitas sediaan radiofarmaka Sm-153 EDTMP minimum 37,50 mCi/ml dan yang terbesar 283,50 mCi/ml, sebanyak 8 buah larutan mempunyai pH 7,5, sedangkan yang lainnya ( 2 buah larutan ) mempunyai pH sebesar 8,5. Kemurnian radiokimia sediaan raiofarmaka Sm-153 EDTMP berkisar antara 90,00 % sampai dengan 98,76 %. Kata Kunci : Evaluasi, Radioisotop, Radiofarmaka, Sm-153, Sm-153 EDTMP EVALUATION OF RADIOISOTOPE PRODUCTION PROCESS OF Sm-153 AND Sm-153 EDTMP RADIOPHARMACEUTICALS. Experiments on the process of Sm-153 radioisotope and labeling of Sm-153 EDTMP radiopharmaceuticals were carried out, as a purpose for evaluation of Sm-153 radioisotope and Sm-153 EDTMP process production in Center for Radioisotope and Radiopharmaceuticals, National Nuclear Energy Agency. This experiments included preparation of Sm2O3target, dissolution of post irradiation, determination of radioactivity concentration of Sm-153 radioisotope, radionuclide purity, EDTMP labeling, determination of radiochemicals purity and pH. In these experiments the total radioactivity Sm-153 product is about 2845.83 mCi to 36963,31 mCi, or with the radioactivity concentration between 474,30 mCi/ml and 6160,55 mCi/ml in the SmCl3solution form. The volume is 6.0 ml, the samarium content is 5.76 mg/ml and the radionuclide purity of Sm-153 is 100 %. All of the Sm-153 EDTMP radiopharmaceuticals product are fullfilled requirements the radioactivity concentration, Sm content, radiochemical purity and pH. The radioactivity concentration of Sm-153 EDTMP radiopharmaceuticals is 37,50 mCi/ml(minimum) to 283,50 mCi/ml (highest). The pH 7.5 were 8 products, and the rest are pH 8.5. Radiochemical purity of Sm-153 EDTMP are round about 90.00 % to 98,76 %. Key Words : evaluation, radioisotope, radiopharmaceutical, Sm-153, Sm-153 EDTMP
VALIDASI METODE PEMBUATAN DAN KENDALl MUTU KIT UBIQUICIDINE UNTUK DETEKSI INFEKSI Widjaksana, Widyastuti; Roseliana, Anna; Lestari, Enny; Tahyan, Yayan; Setyowati, Sri; Humani, Titis Sekar; Kartamihardja, Hussein S
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3590.876 KB)

Abstract

ABSTRAK VALIDASI  METODE  PEMBUATAN  DAN  KENDALl  MUTU  KIT UBIQUICIDINE  UNTUK  DETEKSI INFEKSI. Telah dilakukan pembuatan dan uji mutu radiofarmaka Ubiquicidine 29-41 (UBI 2941)untuk ditandai dengan teknesium 99mTcyang akan digunakan untuk preparat diagnosis infeksi bakteriGram posistif dan jamur. Kit kering UBI telah dibuat secara aseptis dan dianalisis kemumian radiokimia, sterilitas dan apirogenitasnya. HasH penandaan UBI dengan 99mTcdianalisis dengan kromatografi lapis tipis dan kromatografi kertas menggunakan ITLC-SG dengan eluen campuran dapar ammonium asetat 0.1 M 5.2 - metanol (1: I) serta kertas Whatman-l dengan e1uen aseton, sedangkan uji sterilitasnya dilakukan menggunakan medium perbenihan cair Fluid Thioglycolate (FTG) dan Trypton Soy Broth (TSB). Uji in vivo pada hewan percobaan dilakukan pada mencit normal dan yang diinduksi infeksi, sedangkan uji klinis pendahuluan dilakukan pada 5 orang relawan di RS. Hasan Sadikin Bandung dan RSPAD Gatot Soebroto Jakarta yang I orang diantaranya mewakili pasien sehat, dan waktu pengamatan dilakukan pada I jam dan 2 jam setelah penyuntikan dengan 99mTc_UBI.Hasil percobaan menunjukkan efisiensi penandaan sebesar 99,34%, uji sterilitas menunjukkan tidak terjadi pertumbuhan mikroba dalam media uji, uji pirogenitas tidak menunjukkan kenaikan temperatur yang berarti pada kelinci percobaan dan stabilitas kit kering UBI pada penyimpanan di suhu 4°C tidak berubah hingga 12 bulan pengamatan. Biodistribusi pada mencit normal menunjukkan akumulasi radioaktivitas pada ginjal dan kandung kemih, sedangkan pad a mencit yang diinfeksi terlihat adanya penangkapan yang signifikan' pada jaringan yang mengalami infeksi (paha kanan) dibandingkan jaringan yang sehat (paha kiri). Studi pendahuluan pada pasien normal menunjukkan akumulasi radioaktivitas pad a ginjal dan kandung kemih sedangkan pada pasien dengan gejala diare maupun hemoroid terlihat juga adanya penangkapan yang signifikan pada usus dan penangkapan radioaktivitas terse but terlihilt lebih jelas setelah 2 jam. Telah dibuktikan pula kespesifikan dalam pencitraan infeksi bakteri dibandingkan dengan non bakteri (amuba). Hal ini menunjukkan bahwa radiofarmaka 99mTc-Ubiquicidine 29-41 dapat digunakan untuk mendeteksi adanya infeksi secara umum dalam tubuh menggunakan kamera gama dengan waktu pencitraan optimal 2 jam sekaligus juga dapat membedakan antara infeksi yang disebabkan oleh bakteri dan non bakteri. Kata kunci: 99mTc,penandaan, Ubiquicidine, biodistribusi, infeksi ABSTRACT VALIDATION OF PREPARATION AND QUALITY CONTROL METHODS OF UBIQUICIDINE KIT TO BE USED AS INFECTION IMAGING AGENT. Preparation and Quality Control of Ubiquicidine 29-41 (UBI 29-41) to be labelled with 99mTchave been carried out and will be prepared as infection imaging agent specifically for Gram positive bacteria-and fungi. Lyophilised UBI kits was prepared aseptically and analysed for its sterility, apyrogenicity and radiochemical purity. Labeling efficiency of UBI was analysed by thin layer chromatography using ITLC-SG with ammonium acetate 0.1 M pH 5.2-methanol (1: I) as eluants and paper chromatography using Whatman-I paper with acetone as eluant, and its sterility was assesed using bacterial and fungal culture media, i.e fluid thioglycolate (FTG)and trypton soy broth (TSB). In vivo study was carried out in normal mice and infection induced mice, whereas initial clinical study was carried out on 5 volunteers at Hasan Sadikin General Hospital and Gatot Soebroto Army Hospital, which 1 of them represents normal patient. The images were taken I hour and 2 hours post administration. QC results showed labelling efficiency of UBI of 99.34%, no microorganisms growth in culture media, no significant increase in temperature of experimental rabbits and the stability of unlabeled UBI kits during storage at 4°C was unchanged up to 12 months. Biodistribution study in normal mice showed high accumulation in kidneys and bladder, whereas in infected mice higher uptake was alsoobserved in infected area (right thigh) rather than in uninfected one (left thigh). Initial clinical study in normal patient showed high accumulation of radioactivity in kidneys and bladder whereas in 2 patients with symptoms of diarrhoea and haemorroid respectively the uptake was also seen in colon which increased after 2 hours. Uptake of radioactivity was also seen in patient with spondy litis TB but none in patient with amoebic infection who was previously proven infected using other modality. From this experiment it can be concluded that Ubiquicidine 29-41 labeled with 99mTccan be used as infection imaging agent using gamma camera with optimum scanning time of 2 hours post injection and enable to differentiate between bacterial infection and amoebic infection.Keywords: 99mTc,labeling, Ubiquicidine, biodistribution, infection
UJI KUALITAS PRODUK I-131 HASIL BELAH U-235 Wisnukaton, Khadarisman; Suparman, Ibon; Gunawan, Adang Hardi; Lubis, Hotman; Ritonga, Togar Marsangap; Sukmana, Ateng; Tahyan, Yayan; Haffid, Dadang; Lestari, Enny; Sriyono, Sriyono; Herlina, Herlina
Jurnal Radioisotop dan Radiofarmaka Vol 3, No 1 (2000): JURNAL PRR 2000
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3666.88 KB)

Abstract

UJI KUALITAS PRODUK 131I HASIL BELAH 235U. Telah dilakukan uji kualitas terhadap 10 buah cuplikan produk 131I hasil belah 235U. Pemeriksaan cuplikan meliputi penetapan konsentrasi radioaktivitas 131I, pH, kemurnian radiokimia, kontaminasi radionuklida pemancar gamma dan alfa. Semua produk 131I hasil belah dalam percobaan ini pH-nya memenuhi persyaratan yang telah ditetapkan oleh Medi Physic Inc. Konsentrasi radioaktivitas 131I hasil belah 235U tidak ada yang memenuhi syarat. Sembilan cuplikan dari 10 cuplikan memenuhi persyaratan kemurnian radiokimia yang dianalisis dengan cara kromatografi kertas. Delapan cuplikan memenuhi syarat kontaminasi radionuklida pemancar alfa. Sebanyak 6 cuplikan produk 131I memenuhi syarat kontaminasi radionuklida pemancar gamma, dan ada 4 cuplikan yang tidak memenuhi syarat. Dengan demikian semua produk tidak ada yang memenuhi semua persyaratan sesuai dengan persyaratan yang telah ditetapkan oleh Medi Physic Inc. QUALITY CONTROL TESTS OF FISSION PRODUCT 131I. Quality control tests were carried out for 10 samples of fission product 131I obtained from irradiated high enriched uranium target (UI25 = 93%) from 235U. The analysis of samples covered the determination of 131I radioactivity concentration, pH of solution, and radiochemical purity as well as gamma and alpha radionuclide impurities. Results were compared to the Medi Physics quality requirements. The fission produced 131I samples in this experiment met the required pH value but no one met the required radioactive concentration. The radiochemical purity determined by paper chromatography method shows the yield more than 95 %. It was found that eight samples showed alpha emitter contaminants under the permissible value, and two others were higher than the permissible value.