Pengaruh Bahan Pengisi Cangkang Kelapa Sawit Komposit-Silicone Rubber Dalam Permulaan Pemohonan Listrik Fitriah, Fitriah; Kurnianto, Rudi; Rajagukguk, Managam
ELKHA : Jurnal Teknik Elektro Vol. 12 No. 2 October 2020
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v12i2.40941

Abstract

Inception of electrical treeing  can irreversibly deteriorate the insulation of polymeric power cables leading to a complete failure and initial process of degradation in polymer insulation due to a void that experiences high electric field stress in the material. This paper present will study filler’s influence on inception of electrical treeing growth in silicone rubber – oil palm endokaprium composite.  The observed data is inception voltage and time phenomena in two types of test sample, that is " with filler " and " without filler ". Sample of filler consisted of silicone rubber and oil palm endokaprium composite for oil palm endokaprium weight is 0.1 grams and weight silicone rubber 3.9 gram. While the sample without filler is only silicone rubber . It is obtained that the tree inception voltages dan time for “with” dan “without filler” specimens are 8 kV / 182 seconds and 7,5 kV / 137 seconds, respectivelly.. It is considered that “filler”  acted as a barrier for tree inception. We throught that “filler” enhanced dielectric strength of silicone rubber and oil palm endokaprium by disturbing high electric field stress, result in higher tree inception voltage and longer tree inception time.
Reliability Evaluation of Kumpai Feeder Distribution System at PT. PLN (Persero) ULP Siantan Kurniawan, Ari Kurniawan; Fitriah, Fitriah; Arsyad, M. Iqbal
ELKHA : Jurnal Teknik Elektro Vol. 13 No. 2 October 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v13i2.48660

Abstract

The research on reliability index of a feeder aims to evaluate the reliability level of a feeder using the Reliability Index Assessment (RIA) method. This method evaluates the reliability of a 20 kV distribution network by calculating the reliability indexes of each load point. The evaluation results show the reliability index value per section of the Kumpai Feeder at PT. PLN (Persero) ULP Siantan within one year. The SAIFI values are 0.0092; 0.0012; 12,477; 0.0596; 0.0204; 0.0470; 0.0155; 0.0728, the SAIDI values are 0.0277; 0.0042; 37,746; 0.1862; 0.0741; 0.1524; 0.0493; 0.2209, the CAIDI values are 3.0108; 3.5; 3,025; 3.1241; 3.6323; 3.2425; 3.1806; 3.0343, the MAIFI values are 0; 5,480; 0.2145; 0.0020; 0.0038; 0.0042; 0.0006; 0.0014. The calculation results show that the 20 kV distribution system at PT. PLN (Persero) ULP Siantan at the Kumpai Feeder can be categorized as unreliable. Because the SAIFI value of this feeder exceeds the standard set by PT. PLN (Persero) which are 12.477 times/customer/year and 3.2 times/customer/year, respectively. The factors affecting the reliability index of the Kumpai feeder are the number and duration of blackouts, the number of customers, and the length of the distribution system channel.
Rancang Bangun Aplikasi Perencanaan Instalasi Penerangan Berbasis Sistem Pakar Sirait, Alen Gonzales; Sirait, Bonar; -, Fitriah
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2021): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem penerangan menjadi salah satu fasilitas pendukung sebuah bangunan. Penerangan yang baik dapat ditentukan berdasarkan pada peraturan dan ketentuan sesuai dengan standar bangunan yang dipilih. Di dalam proses perhitungan manual akan memakan waktu yang panjang, sehingga di dalam penelitian ini akan merancang dan membuat sistem aplikasi perencanaan perhitungan instalasi listrik penerangan dengan menggunakan sistem pakar agar perhitungan menjadi tepat dan akurat. Pembuatan aplikasi ini menggunakan Microsoft Office Excel dengan (sheet to sheet dan hyperlink). Dalam merencanakan sistem pakar ini menggunakan metode studi literatur, observasi, dan deskriptif analitis. Pada tahap perencanaannya dilakukan beberapa perhitungan yaitu menghitung dengan sistem manual dan sistem pakar, intensitas penerangan, daya total, dan besar arus pengaman MCB. Sistem aplikasi ini hanya menggunakan 3 buah jenis lampu yaitu lampu TL, lampu LED Philips, dan lampu LED Hannochs. Perhitungan dilakukan dengan membandingkan hasil sistem manual dan sistem pakar. Berdasarkan hasil perhitungan jumlah lampu menggunakan perhitungan manual maupun menggunakan aplikasi sistem pakar dari hasil tersebut didapat besar rata-rata persentase error adalah 0,02%, untuk perhitungan daya total dan perhitungan besar arus pengaman didapat persentase error sebesar 0,00%. Aplikasi sistem pakar ini sangat membantu dan mempermudah dalam perhitungan sistem penerangan  instalasi listrik seperti intensitas penerangan, daya total dan besar arus pengaman, sehingga adanya aplikasi sistem pakar ini dapat menghemat waktu dalam penyelesaian suatu masalah yang kompleks dan solusi untuk mempersingkat perhitungan yang rumit dapat terpecahkan.
PENERAPAN DEMAND SIDE MANAGEMENT PADA HOTEL KAPUAS PALACE PONTIANAK Hermanto, Bambang; Sirait, Bonar; -, Fitriah
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2021): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu metode yang sekarang dipakai untuk mengefisienkan pemakaian energi listrik adalah dengan metode DSM yang akan menghasilkan strategi yang akan memberikan peluang penghematan biaya listrik pada saat tingkat hunian meningkat. Pada penelitian ini dipilih dua strategi metode Demand Side Management (DSM) yaitu peak clipping dan load shifting untuk menurunkan beban puncak di sektor Gedung Hotel Kapuas place Pontianak  yang difokuskan pada beban lampu penerangan, AC, pompa, dan water heater. Dari hasil penelitian pada kondisi eksisting beban puncak yang terjadi pada Hotel Kapuas Palace Pontianak sebesar 163,71 kW dan beban rata-rata sebesar 124,90 kW, serta faktor beban sebesar 0,76. Pemakaian energi listrik per tahun sebesar Rp.1.094.127,65 dan total biaya per tahun sebesar Rp.1.223.711.560,00. Pemakaian energi listrik per tahun dengan menerapkan strategi Peak Clipping sebesar Rp.1.027.566,25 dan total biaya per tahun sebesar Rp.1.147.233.639,54. Penerapkan Demand Side Management dengan strategi Peak Clipping pada Hotel Kapuas Palace Pontianak dapat menghasilkan penghematan biaya sebesar 6,25%. Penerapkan strategi Load Shifting  memperoleh beban puncak sebesar 147,04 kW dan beban rata-rata sebesar 124,90 kW, serta faktor beban sebesar 0,85. Pemakaian energi listrik per tahun dengan menerapkan strategi Load Shifting sebesar Rp.1.094.127,65 dan total biaya per tahun sebesar Rp.1.214.502.785,96. Penerapkan Demand Side Management dengan strategi Load Shifting pada Hotel Kapuas Palace Pontianak dapat menghasilkan penghematan biaya sebesar 0,75%.
Photovoltaic parameters estimation of poly-crystalline and mono-crystalline modules using an improved population dynamic differential evolution algorithm Ayong Hiendro; Ismail Yusuf; Fitriah Husin; Kho Hie Khwee
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 5: October 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i5.pp4538-4548

Abstract

Photovoltaic (PV) parameters estimation from the experimental current and voltage data of PV modules is vital for monitoring and evaluating the performance of PV power generation systems. Moreover, the PV parameters can be used to predict current-voltage (I-V) behavior to control the power output of the PV modules. This paper aimed to propose an improved differential evolution (DE) integrated with a dynamic population sizing strategy to estimate the PV module model parameters accurately. This study used two popular PV module technologies, i.e., poly-crystalline and mono-crystalline. The optimized PV parameters were validated with the measured data and compared with other recent meta-heuristic algorithms. The proposed population dynamic differential evolution (PDDE) algorithm demonstrated high accuracy in estimating PV parameters and provided perfect approximations of the measured I-V and power-voltage (P-V) data from real PV modules. The PDDE obtained the best and the mean RMSE value of 2.4251E-03 on the poly-crystalline Photowatt-PWP201, while the best and the mean RMSE value on the mono-crystalline STM6-40/36 was 1.7298E-03. The PDDE algorithm showed outstanding accuracy performance and was competitive with the conventional DE and the existing algorithms in the literature.
Quality Improvement of 20 KV Voltage Profile Of PT. PLN (Persero) Ketapang According to SPLN No.72 Of 1987 Fitriah Husin; Bonar Sirait
ELKHA : Jurnal Teknik Elektro Vol. 14 No. 1 April 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v14i1.48511

Abstract

This study aims to determine the magnitude of the increase in the voltage profile of the 20.kV distribution network system of PT. PLN (Persero) Ketapang with the installation of reactive power injection equipment. The research method used is the Newton Raphson power flow method with MATLAB simulation program. From the results of these calculations, Pawan 2 and Pawan 6 load buses each have a voltage drop above 5%, which is found on 42 buses. To overcome this, reactive power injection (Qc) was carried out: 150 KVAR on bus 26 of Pawan 2, and 900 KVAR on bus 40 and 46, and 600 KVAR on bus 51 of Pawan 6. This leads to the increase in voltage drop percentage on Pawan 2 and Pawan 6, thus, the profile meets SPLN No. 72 of 1987, which is below 5%.
ANALISA PERHITUNGAN DISTRIBUSI TEGANGAN DAN ARUS BOCOR PADA ISOLATOR RANTAI Vanisa Gustiana; Bonar Sirait; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 9, No 2: Juli 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v9i2.49158

Abstract

Penelitian ini melakukan perhitungan distribusi tegangan dan arus bocor serta efisiensi pada isolator rantai dengan melakukan penambahan isolator sebanyak 4,5,6 dan 7 buah pada isolator rantai. Mengingat sedikitnya tulisan yang berhubungan dengan distribusi tegangan pada isolator rantai ini, maka menjadi alasan untuk membahas mengenai masalah ini. Perhitungannya menggunakan metode Eliminasi Gauss berdasarkan pendekatan hukum Kirchoff dengan menggunakan program Matlab. Adapun hasil simulasi perhitungan yang dilakukan pada tegangan 150 kV, 275 kV, 500 kV dan 1000 kV menggunakan 4, 5 dan 6 isolator dengan efisiensi  pada variasi tinggi sebesar  132.43% , 183.73 % dan 439.38 % dan variasi rendah 141.71%, 221.69 % dan 1589 %. Arus bocor yang dihasilkan juga tidak lebih dari 1 kA dimana nilai ini relatif kecil dan masih bisa ditoleransi. Efisiensi yang dihasilkan 7 isolator bernilai negatif dimana hasil efisiensi untuk variasi tinggi sebesar -384 % dan variasi rendah -181 %. Berdasarkan analisa hasil perhitungan distribusi tegangan yang menggunakan variasi tinggi dan rendah nilainya baik apabila jumlah isolator yang digunakan tidak lebih dari 6 isolator, hal ini dipengaruhi dari nilai kapasitansi dan jumlah isolator yang digunakan. Selama hasil efisiensi isolator lebih dari 100 % maka isolator yang digunakan baik dan begitu juga sebaliknya. Pada transmisi tegangan tinggi nilai kapasitansi dipengaruhi oleh besar isolator, jarak antar isolator, dan jarak konduktor dengan klem isolator.
STUDI PENGEMBANGAN JARINGAN DISTRIBUSI GUNA MEMENUHI KEBUTUHAN ENERGI LISTRIK DI KAWASAN KIJING Simon Agung Agebeto Silalahi; M. Iqbal Arsyad; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 2: Juli 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i2.57250

Abstract

Pelabuhan Internasional Kijing membutuhkan pasokan tenaga listrik yang cukup besar dan memakan biaya yang tidak sedikit. Salah satu konsumen terbesar dalam penggunaan listrik di daerah Kijing. Untuk itu dibutuhkan adanya pengembangan suatu sistem distribusi guna dapat memenuhi kebutuhan energi listrik dalam proses pembangunan pelabuhan tersebut kapasitas gardu induk distribusi 4999 KVA. Tujuan dari penelitian adalah untuk mendapatkan pengembangan optimum gardu induk distribusi dalam usaha mengatasi pertumbuhan beban dan Mencari pendekatan dalam mengatasi pertumbuhan beban khususnya di Kawasan Kijing. Perhitungan – perhitungan pada skripsi ini dilakukan dengan bantuan komputer dengan menggunakan bahasa pemprograman Fortran. Jika beban atau kebutuhan daya pada pelabuhan internasional Kijing diketahui misalnya kerapatan beban menjadi D 60 kW/km2 pada desember tahun 2022 ini, maka akan dapat diperkirakan nilai – nilai optimum kapasitas GID untuk mengatasi beban di area Kijing selama 8 tahun kemudian pada tahun 2030 antara lain seperti  perhitungan sebagai berikut : - Dalam hasil perhitungan komputer terlihat bahwa nilai – nilai optimum kapasitas GID untuk mengatasi beban sampai tahun 2030 pada saat kerapatan beban mencapai 70 kW/km2 adalah sebagai berikut : Penampang penghantar   =  120 mm2 Kapasitas gardu induk distribusi  =  5833 KVA Kapasitas saluran penyulang =  3102,23 KVA Jumlah gardu induk dalam sistem beban  =  1 Jumlah saluran  penyulang =  2 Jatuh tegangan yang terjadi  =  1,39  % Besar arus yang mengalir di bawah KHA penyulang  =  89,556 A . Biaya total sistem  = Rp. 1.041.920.000,-
AUDIT ENERGI SISTEM PENCAHAYAAN DAN SISTEM PENGKONDISIAN UDARA DI RSUD ABDUL AZIZ SINGKAWANG Sari Bianda; M. Iqbal Arsyad; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 2: Juli 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i2.56760

Abstract

Profil pemakaian energi listrik memberikan gambaran tentang konsumsi pemakaian energi listrik dari setiap ruangan dimasing-masing gedung. Tujuan penelitian ini untuk mengetahui nilai Intensitas Konsumsi Energi (IKE) listrik dan Peluang Hemat Energi (PHE) pada RSUD Abdul Aziz Singkawang. Metode penelitian yang digunakan adalah studi literatur, observasi lapangan dan analisis Deskripstif. Untuk metode perhitungan yang digunakan adalah audit energi rinci dan perhitungan dibantu menggunakan microsoft excel. Nilai IKE pada tahun 2021 sebesar 95,820 kWh//tahun. Berdasarkan standar IKE yang ditetapkan untuk Rumah Sakit sebesar 380 kWh//tahun, nilai IKE ini masih tergolong sangat efisien dan total PHE pada tahun 2021 sebesar 1.131.389,4 kWh//tahun. Nilai IKE akhir sebelum melakukan PHE sebesar 105,209 kWh//tahun dengan biaya sebesar Rp. 1.910.954.940 dan setelah melakukan PHE sebesar 87,624 kWh//tahun dengan biaya sebesar Rp. 1.591.547.523 dalam penelitian ini didapatlah penghematan sebesar Rp. 319.407.417. Pada total konsumsi energi listrik yang sudah didapat masih bisa menekan angka IKE dengan cara melakukan penggantian lampu CFL dan TL menjadi lampu LED untuk sistem pencahayaan, untuk sistem tata udara mengganti freon jenis R-22, R32 dan R-410 menjadi freon jenis MC-22. Penggantian tersebut akan menghasilkan perbandingan dan penghematan konsumsi pemakaian energi listrik dilingkungan RSUD Abdul Aziz Singkawang.
ANALISIS AUDIT ENERGI SISTEM PENCAHYAAN DAN TATA UDARA DI UNIVERSITAS MUHAMMADIYAH PONTIANAK Muhammad Muchlis Ansor; Purwoharjono -; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 1: Januari 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i1.52046

Abstract

Profil pemakaian energi listrik memberikan gambaran tentang distribusi pemakaian energi dan intensitas konsumsi energi. Tujuan penelitian ini untuk mengetahui besarnya nilai Intensitas Konsumsi Energi (IKE) dan Peluang Hemat Energi (PHE) pada Gedung Teori Bersama Universitas Muhammadiyah Pontianak dan merekomendasikan penghematan energi listrik. Metode penelitian yang digunakan yaitu studi literatur, observasi, metode analisis deskriptif dengan perhitungan yang dibantu oleh Microsoft Excel. Nilai IKE pada tahun 2018 sebesar 90,30 kWh/m2 per tahun, tahun 2019 sebesar 112,49 kWh/m2 per tahun saat kondisi sebelum pandemi covid-19 dan tahun 2020 sampai bulan Agustus tahun 2021 saat pandemi covid-19 sebesar 134,15 kWh/m2 per tahun,. Berdasarkan standar IKE yang ditetapkan yaitu 240 kWh/m2 per tahun, nilai IKE masih tergolong efisien dan total Peluang Hemat Energi (PHE) pada tahun 2018 sebelum pandemi covid-19 sebesar 116,544 kWh, dan total PHE pada tahun 2019 sebelum pandemi covid-19 sebesar 64,48 kWh, total PHE pada tahun 2020 sampai bulan Agustus tahun 2021 saat pandemi covid-19 sebesar 143,136 kWh. Pada total konsumsi energi listrik yang didapat masih bisa menekan nilai IKE dengan cara melakukan penggantian lampu CFL (SL) ke lampu LED untuk sistem pencahayaan dan penggantian Refrigerant HCFC R-22 dengan menggunakan Refrigerant Musicool MC-22 untuk sistem tata udara AC. Penggantian tersebut dapat menghasilkan sebuah perbandingan dan penurunan konsumsi energi listrik pada gedung teori bersama Universitas Muhammadiyah Pontianak.