Pengaruh Komposisi Material Semikonduktor Dalam Menurunkan Energi Band Gap Terhadap Konversi Gelombang Mikro Mohammad Wahyu Aminullah; Herry Setiawan; Adri Huda; Hazairin Samaulah; Sri Haryati; Muhammad Djoni Bustan
Jurnal EECCIS Vol 13, No 2 (2019)
Publisher : Fakultas Teknik, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Uji pengaruh komposisi material semikonduktor yang dilakukan oleh sintesis material menggunakan metode kopresipitasi dengan sintering 1000C selama 1 jam. Variabel tetap dalam proses sintesis material adalah NH4OH (80ml), Temperatur (500C), dan Aquades (500ml), sedangkan variasi variabelnya adalah komposisi material (NaxCuyZnz). Penelitian ini dilakukan untuk melihat pengaruh temperatur material yang digunakan untuk mengukur resistansi mulai dari 30,35, 40, 45, dan 500C. Metode yang digunakan adalah untuk secara langsung menguji pengaruh komposisi material terhadap konversi gelombang mikro. Hasil penelitian menunjukkan bahwa penurunan terkecil pada energi band gap diperoleh dengan menggunakan komposisi material 50% ZnCl2, 25% CuCl2, dan 25% NaCl. Rata-rata penurunan energi band gap karena pengaruh variasi komposisi material semikonduktor  berhasil dari 2,63 menjadi 0,79 eV. Fraksi x, y, dan z dalam material ditentukan dari analisis PMI (ARC-MET 8000) dan analisis Scanning Elektron Microscope (SEM) VEGA 3 TESCAN. Kata kunci: Konversi gelombang mikro, semikonduktor, energi band gap
Inovasi lengkuas Sebagai Produk Makanan Ringan dan Tambahan Pendapatan di Desa Sukamulya Moh. Wahyu Aminullah; Muhni Pamuji; Dina Fitria
Dinamisia : Jurnal Pengabdian Kepada Masyarakat Vol. 6 No. 3 (2022): Dinamisia: Jurnal Pengabdian Kepada Masyarakat
Publisher : Universitas Lancang Kuning

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/dinamisia.v6i3.7869

Abstract

This community service is carried out with the aim of optimizing the use of galangal and community empowerment in Sukamulya Village in increasing income in a sustainable manner. The method used in this activity is by direct counseling and training to the community and making galangal innovations into galangal chips. The results obtained are that the large potential of galangal must be balanced with optimal utilization by processing it first rather than selling it directly to agents. This is also supported by the enthusiasm of the community in improving welfare. The need for collaboration in terms of marketing and sales from various parties, both local governments, communities, campus parties, and other stakeholders in order to improve the community's economy, and promote healthy snacks in the midst of this COVID-19 pandemic situation. This service can indirectly increase people's knowledge in managing the potential of galangal; cultivate the mindset of collaborating to form a community that has the potential to increase people's economic income; and efforts to produce galangal chips as souvenirs from Sukamulya village.
PENGARUH PENGGUNAAN GROUNDING PADA KWH METER PRABAYAR Moh. Wahyu Aminullah; Muhni Pamuji; Yuslan Basir
TESLA: Jurnal Teknik Elektro Vol 24, No 1 (2022): TESLA: Jurnal Teknik Elektro
Publisher : Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/tesla.v24i1.13265

Abstract

The grounding system must be connected to every electrical panel of the building so that electrical installations, equipment, and people in the building can avoid the danger of overcurrent or voltage. In fact, the installation of grounding on prepaid kWh meters, especially in residential areas, is partially grounded because of the reason that errors often occur. This research was conducted when the prepaid kWh meter used grounding, kWh without using grounding, and kWh using grounding combined to Neutral with a different voltage source. The results of the study with three different test methods show that there is a difference in Power (W) and information on the Prepaid kWh Meter when testing the voltage varying from 270 V to TRIP at a voltage below 80 V. The power when testing using grounding is more maximal at a voltage of 220 -270V. when the voltage drops, testing using grounding is better because at a voltage of 140V there is already a warning sign in the form of a palm image on the prepaid kWh meter. Whereas in the test without using grounding, the warning appears at a voltage of 110V. The calculation of usage error at 220V shows that the smallest prepaid kWh meter error is using grounding of 1.063%. Meanwhile, the prepaid kWh meter error without grounding is 3.76%, and using grounding connected to neutral is 35.38%. Testing and calculating the prepaid kWh meter is very good when it is grounded. Starting from calculating small errors to maintaining losses from leakage currents in home electrical equipment and installations. ABSTRAK:Sistem grounding harus terkoneksi pada setiap panel listrik bangunan gedung agar instalasi listrik,peralatan, dan manusia yang berada pada bangunan tersebut dapat terhindar dari bahaya arus atau tegangan lebih. Kenyataannya pemasangan grounding pada kWh meter prabayar terutama di area perumahan sebagian tidak dipasang grounding dengan alasan sering terjadi error. Penelitian ini dilakukan pada saat kWh meter prabayar menggunakan grounding, kWh tanpa menggunakan grounding, dan kWh menggunakan grounding di gabung ke Netral dengan sumber tegangan yang berbeda. Hasil Penelitian dengan tiga metode pengujian yang berbeda menunjukkan bahwa terdapat perbedaan Daya (W) dan keterangan pada kWh Meter Prabayar saat dilakukan pengujian tegangan yang bervariasi dari 270 V hingga TRIP pada tegangan dibawah 80 V. Daya pada saat pengujian menggunakan grounding lebih maximal pada tegangan 220-270V. ketika tegangan turun, pengujian menggunakan grounding lebih baik dikarenakan pada tegangan 140V sudah ada tanda peringatan berupa gambar telapak tangan pada kWh meter prabayar. Sedangkan pada pengujian tanpa menggunakan grounding, maka  peringatan tersebut muncul pada tegangan 110V. Perhitungan error pemakaian pada tegangan 220V menunjukkan error kWh meter prabayar terkecil adalah menggunakan grounding sebesar 1,063%. Sedangkan error kWh meter prabayar tanpa grounding sebesar 3,76%, dan menggunakan grounding disambung ke netral sebesar 35,38%. Pengujian dan perhitungan kWh meter prabayar sangat baik bila dipasang grounding. Mulai dari perhitungan error yang kecil hingga menjaga kerugian dari arus bocor pada peralatan maupun instalasi listrik rumah.
PERANCANGAN KOMPOR LISTRIK BERBASIS PANEL SURYA TERHADAP PENGARUH PANJANG COIL Moh. Wahyu Aminullah; Haryadi Haryadi; Dina Fitria
Jurnal Teknik Elektro Uniba (JTE UNIBA) Vol. 6 No. 2 (2022): JTE UNIBA (Jurnal Teknik Elektro Uniba)
Publisher : Lembaga Penelitian Universitas Balikpapan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/jteuniba.v6i2.108

Abstract

Solar energy can be obtained easily and free of charge, but the conversion results are not entirely easy and free. In this study we tried to develop alternative energy from sunlight or solar panels as an energy source that can produce electrical energy (DC) as an energy source for electric stoves. The induction electric stove was self-assembled in this study with a cross-sectional area of ​​10 cm2. In testing the induction electric stove was used to heat water for 15 minutes. The test was carried out from 09:00 – 15:00 for 3 days using a coil with various coil lengths (1m, 2m, and 3m). The results showed that the coil length of 1 m resulted in the lowest inductance value of 125.6 x 10-9 H, and the lowest power of 119,025 Wh. While the coil with a length of 3 m produces the best inductance value of 376.8 x 10-9 H, and the best power of 125.235 Wh. The results showed that the greater the coil length value, the greater the inductance and power generated.
PENGARUH PENGGUNAAN GROUNDING PADA KWH METER PRABAYAR Moh. Wahyu Aminullah; Muhni Pamuji; Yuslan Basir
TESLA: Jurnal Teknik Elektro Vol 24 No 1 (2022): TESLA: Jurnal Teknik Elektro
Publisher : Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/tesla.v24i1.13265

Abstract

The grounding system must be connected to every electrical panel of the building so that electrical installations, equipment, and people in the building can avoid the danger of overcurrent or voltage. In fact, the installation of grounding on prepaid kWh meters, especially in residential areas, is partially grounded because of the reason that errors often occur. This research was conducted when the prepaid kWh meter used grounding, kWh without using grounding, and kWh using grounding combined to Neutral with a different voltage source. The results of the study with three different test methods show that there is a difference in Power (W) and information on the Prepaid kWh Meter when testing the voltage varying from 270 V to TRIP at a voltage below 80 V. The power when testing using grounding is more maximal at a voltage of 220 -270V. when the voltage drops, testing using grounding is better because at a voltage of 140V there is already a warning sign in the form of a palm image on the prepaid kWh meter. Whereas in the test without using grounding, the warning appears at a voltage of 110V. The calculation of usage error at 220V shows that the smallest prepaid kWh meter error is using grounding of 1.063%. Meanwhile, the prepaid kWh meter error without grounding is 3.76%, and using grounding connected to neutral is 35.38%. Testing and calculating the prepaid kWh meter is very good when it is grounded. Starting from calculating small errors to maintaining losses from leakage currents in home electrical equipment and installations. ABSTRAK:Sistem grounding harus terkoneksi pada setiap panel listrik bangunan gedung agar instalasi listrik,peralatan, dan manusia yang berada pada bangunan tersebut dapat terhindar dari bahaya arus atau tegangan lebih. Kenyataannya pemasangan grounding pada kWh meter prabayar terutama di area perumahan sebagian tidak dipasang grounding dengan alasan sering terjadi error. Penelitian ini dilakukan pada saat kWh meter prabayar menggunakan grounding, kWh tanpa menggunakan grounding, dan kWh menggunakan grounding di gabung ke Netral dengan sumber tegangan yang berbeda. Hasil Penelitian dengan tiga metode pengujian yang berbeda menunjukkan bahwa terdapat perbedaan Daya (W) dan keterangan pada kWh Meter Prabayar saat dilakukan pengujian tegangan yang bervariasi dari 270 V hingga TRIP pada tegangan dibawah 80 V. Daya pada saat pengujian menggunakan grounding lebih maximal pada tegangan 220-270V. ketika tegangan turun, pengujian menggunakan grounding lebih baik dikarenakan pada tegangan 140V sudah ada tanda peringatan berupa gambar telapak tangan pada kWh meter prabayar. Sedangkan pada pengujian tanpa menggunakan grounding, maka  peringatan tersebut muncul pada tegangan 110V. Perhitungan error pemakaian pada tegangan 220V menunjukkan error kWh meter prabayar terkecil adalah menggunakan grounding sebesar 1,063%. Sedangkan error kWh meter prabayar tanpa grounding sebesar 3,76%, dan menggunakan grounding disambung ke netral sebesar 35,38%. Pengujian dan perhitungan kWh meter prabayar sangat baik bila dipasang grounding. Mulai dari perhitungan error yang kecil hingga menjaga kerugian dari arus bocor pada peralatan maupun instalasi listrik rumah.
Pengaruh Ketinggian Dan Redaman Dalam Meningkatkan Daya Keluaran Pada Panel Surya Moh. Wahyu Aminullah; Iskandar Iskandar; Yuslan Basir
PROtek : Jurnal Ilmiah Teknik Elektro Vol 9, No 2 (2022): PROtek : Jurnal Ilmiah Teknik Elektro
Publisher : Program Studi Teknik Elektro Universitas Khairun

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33387/protk.v9i2.3294

Abstract

One of the problems of laying solar panels and attenuation will affect the output power of the solar panels. Several other studies have been carried out with different heights and the addition of attenuation will increase the output power of solar panels. This research was conducted using experimental methods for 6 designs that have been planned. Design 1 solar panel without height and without attenuation, design 2 solar panels without height using attenuation, design 3 solar panels with a height of 10 m and without attenuation, design 4 solar panels with a height of 10 m and use attenuation, design 5 solar panels with a height of 75 m without using attenuation and design 6 solar panels with a height of 75 m and using attenuation. This study aims to determine the effect of changing the height of the solar panels and adding attenuation to see how much power the solar panels produce when they are sunny. Measurement of voltage (Voc) and current (Isc) was carried out for 5 days. The results showed that the highest average output power of solar panels was in design 6 of 45.16 W, while the lowest average output power of solar panels was in design 1 of 41.43 W. The output power of solar panels in design 6 is 8 .3% more than design 1
Pengaruh Pengaturan Rele Jarak Terhadap Proteksi Utama pada Penghantar SUTET 500kV Moh. Wahyu Aminullah; Dyah Utari Yusa Wardhani
Jurnal Ampere Vol. 7 No. 2 (2022): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v7i2.9069

Abstract

SUTET 500 kV Muara Enim merupakan Saluran Udara Tegangan Tinggi yang direncanakan  dibangun di Sumatera Selatan menuju GITET 500 kV New Aur Duri beroperasi menggunakan 2 Set Inter Bus Transformator (IBT) dengan kapasitas 2 x 500 MVA. Pemasangan Distance Relay pada GITET 500 kV Muara Enim adalah sebagai salah satu proteksi dalam pengoperasian tersebut. Tujuan Penelitian ini adalah melakukan perhitungan nilai setting Distance Relay yang sangat diperlukan dalam pengoperasian agar tidak terjadi kegagalan proteksi pada penghantar. Data perhitungan Settingan Distance Relay meliputi data penghantar, rasio CT dan PT. Kapasitas Transformator yang terpasang memiliki daya sebesar 500 MVA. Hasil perhitungan menunjukkan arus hubung singkat terbesar pada saluran transmisi SUTET 500 kV Muara Enim - New Aur Duri dengan panjang saluran 271,37 km didapatkan arus hubung singkat satu fasa ke tanah sebesar 7.374,9 A. Setting distance relay yang didapatkan dengan nilai arus hubung singkat satu fasa ke tanah setelah diturunkan dengan arus trafo didapatkan nilai 1,8 A.
Pendampingan Penanaman dan Mengoptimalkan Pemanfaatan Lahan Tidur Menggunakan Polybag di Kelurahan Sukamulya Kecamatan Sematang Borang Dewi Rawani; Dina Fitria; Muhni Pamuji; Moh. Wahyu Aminullah; R.A. Nurul Moulita; Ahmad Malik Abdul Aziz; M. Alamin
PUBLIKASI PENGABDIAN KEPADA MASYARAKAT Vol 3 No 1 (2023)
Publisher : Fakultas Ekonomi dan Bisnis Universitas Multi Data Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35957/padimas.v3i1.5493

Abstract

Polybag merupakan kantong plastik berwarna hitam dengan lubang-lubang kecil sebagai sirkulasi untuk menanam tanaman yang sebagai alternatif dengan melakukan usahatani tanpa memeliki lahan yang luas. Kelebihan dari berusahatani menggunakan polybag adalah memanfaatkan ruang kosong untuk menyokong kebutuhan dapur, menambah keindahan alami lingkungan, menciptakan taman cantik di lahan terbatas, meningkatkan suplai oksigen di lingkungan sekitar, tanpa melakukan pengolahan tanah (mencangkul/ membajak), fleksibel (dapat dengan mudah diletakkan di mana saja), relatif murah dan mudah pembuatannya terakhir anti banjir. Tujuan dari kegiatan ini adalah untuk mengetahui alternatif lain dalam berusahatani selain menggunakan lahan terbuka yaitu dengan menggunakan polybag agar mengoptimalkan suatu lahan pertanian pada kelompok tani “Melati” di Kelurahan Sukamulya Kecamatan Sematang Borang Kota Palembang.
PERANCANGAN SISTEM PENDETEKSI DAN PENANGGULANGAN BANJIR MENGGUNAKAN ESP32 BERBASIS IOT Yuslan Basir; M.Rizki Adi Pratama; Moh. Wahyu Aminullah
Jurnal Ilmiah Giga Vol 26, No 1 (2023): Volume 26 Edisi 1 Tahun 2023
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47313/jig.v26i1.2127

Abstract

The design of a flood detection and prevention system using an IoT-based esp32 which functions to unify the water level and can be controlled via a smartphone with the blynk application, this tool is designed using the esp32 controller as a wifi module, the water level sensor is a marker of the water discharge level and the relay works as a switch. The way this tool works is to detect the arrival of flooding through a level sensor and the data is directed to the esp32 microcontroller as a medium and sent through the output of the light indicator, LCD display and smartphone, a blynk application called flood monitoring is applied, if the water touches the level 3 sensor it turns on and sends notification to the red light indicator. LCD display and the blynk application, the flood detection and control system can work well after being tested for flood monitoring and control through the blynk application.