Tinjauan Ekohidraulik Pada Uji Model Fisik Bangunan Pelimpah Waduk Pidekso Kabupaten Wonogiri Suprijanto, Heri; Masrevaniah, Aniek; Prasetijo, Hari; Sisinggih, Dian; Primantyo, Andre
Jurnal Teknik Pengairan: Journal of Water Resources Engineering Vol 4, No 1 (2013)
Publisher : Fakultas Teknik, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1432.09 KB)

Abstract

Within this physical hydraulic model of spillway of the Pidekso Dam, the experiment consisted of 9-series of testing; 4-series were testing of narrowing the angle of transition channel by 24 degree while 5others were by 12 degree. For the testing of series No.0 (original design) to No.8, the flow capacity was adequate for various discharges over spillway and outlet structure. Overall, the best hydraulic performance of the model was achieved by series No.4 in term of flow condition (uniformly distributed). This was a model of transition channel with angle of transition of 12 degree and no baffle apron used.Basically, all of testing of the model series No.0 to No.8 brought the positive impact to the downstream-part (section No.36) by considering the dissolved oxygen (DO) level. It was ranging from 11.1 mg/l to 14.2 mg/ l. According to the results of DO level, then only the series No.0 to No.3 were chosen as alternatives design for the case of transition channel with the angle of 24 degree combined with various dimensions of baffle apron. There were regular changes of DO level but the values were still lying above the minimum requirement level and were not harmful for fishery.By respecting to the eco-hydraulic concept, the downstream waterway was designed to be the stone pitching combined with vegetation. It was suggested that the bare floodplain at downstream-part need to be greening by mean of vegetation.Keyword: dam, spillway, baffle apron, dissolved oxygen
Determining Infiltration Rate from Infiltration Measurement with Flooding Method by Turftech Infiltrometer Khaerudin, D Noorvy; Primantyo, Andre; Rahardika, Ryan
Civil and Environmental Science Journal (CIVENSE) Vol 2, No 1 (2019)
Publisher : Fakultas Teknik UB

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/ub.civense.2019.00104

Abstract

The density of the soil in this study estimate parameters with a dry bulk density. variation of soil density based on urban land us and then grouped into heavy, medium, and high-density soil. the rate of infiltration testing is performed by using turftech infiltrometer. and then analyzed with an infiltation horton modification models. the specification of turftech double ring infiltrometer are 6.03 cm for inner ring diameter and 10.79 cm for outer ring diameter. the result of infiltration rate observations is infiltration rate for higher density soil and land slope had low influences. the results showed that the turftech ifiltrometer that is used produced well results with 87% accuracy compared with the horton equation infiltration rate model. for the measurement results feasibility, then the turftech infiltrometer unable to represent for the land slope and density, because from the regression test the relationship between land slope and density toward infiltration rate was not significant and obtained average of 38% from the obtained r2.