Claim Missing Document
Check
Articles

Monitoring Korosi Discharge Conveyor F pada Tambang Batubara PT XYZ di Kabupaten Bungo, Provinsi Jambi Rahmat Fauzi; Elfida Moralista; Zaenal
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5414

Abstract

Abstract. The need for coal is increasing every year to make it easier to transport it using a mechanical device in the form of a conveyor that can increase work efficiency in coal mines. Conveyor structures made of carbon steel material are prone to corrosion due to the influence of the surrounding environment, so they can be damaged and reduce the remaining life of the conveyor structure. The research methodology used was measuring the decrease in the thickness of the conveyor structure which was applied using the Smart Sensor Ultrasonic Thickness Gauge TT 130. Measurements were made on a 125 meter long conveyor structure and 32 test points. The environmental conditions of the study area are based on statistics for 2016–2020 with an average rainfall of 200.48 mm/year, an average air temperature of 25.37ºC and a relative humidity of 87.46%. The type of corrosion that occurs in the conveyor structure is uniform corrosion. The corrosion control method applied is the 3 layer system coating method, which uses a primary coating Seaguard 5000, intermediate coating uses Sherglass FF and top coating uses Aliphatic Acrylic Modifield Polyurethane. The corrosion rate ranges from 0.1827–0.3267 mm/year which is included in the good category based on the relative corrosion resistance table of steel. The design life of the conveyor structure is 15 years and the service life is 7.5 years, while the remaining service life from the calculation results ranges from 6.53–8.79 years. because of that there are 5 test points or 15,6% predicted not to reach the design life of 15 years. Abstrak. Kebutuhan batubara setiap tahun semakin meningkat untuk mempermudah setiap pengangkutannya menggunakan alat mekanis berupa conveyor yang dapat meningkatkan efesiensi kerja pada tambang batubara. Struktur conveyor yang terbuat dari material baja karbon rentan mengalami korosi akibat dari pengaruh lingkungan sekitarnya, sehingga dapat mengalami kerusakan dan mengurangi remaining service life struktur conveyor. Metodologi penelitian yang digunakan adalah pengukuran pengurangan ketebalan struktur conveyor yang diaplikasikan menggunakan alat Smart Sensor Ultrasonic Thickness Gauge TT 130. Pengukuran dilakukan pada struktur conveyor sepanjang 125 meter dan 32 test point. Kondisi lingkungan daerah penelitian berdasarkan statistik tahun 2016–2020 dengan curah hujan rata-rata sebesar 200,48 mm/tahun, temperatur udara rata-rata sebesar 25,37ºC dan kelembapan relatif 87,46%. Jenis korosi yang terjadi pada struktur conveyor adalah jenis korosi merata. Metode pengendalian korosi yang diaplikasikan yaitu metode coating sistem 3 layer, dimana menggunakan primer coating Seaguard 5000, intermediate coating menggunakan Sherglass FF dan top coating menggunakan Aliphatic Acrylic Modifield Polyurethane. Corrosien rate berkisar 0,1827–0,3267 mm/tahun yang termasuk kedalam kategori good berdasarkan tabel ketahanan korosi relatif baja. Umur desain struktur conveyor 15 tahun dan umur pakai 7,5 tahun, sedangkan remaining service life dari hasil perhitungan berkisar 6,53–8,79 tahun. Oleh sebab itu terdapat 5 test point atau 15,6% diprediksi tidak dapat mencapai umur desain yaitu 15 tahun.
Remaining Service Life Discharge Conveyor G pada Tambang Batubara PT GHI di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan Nurul Azizah; Elfida Moralista; Zaenal
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5490

Abstract

Abstract. The transfer of coal material at PT GHI in Tanah Laut Regency, South Kalimantan Province usually uses conveyors. This conveyor is one of the mechanical devices used to move material from one place to another. This conveyor structure has a carbon steel base material which is a material that is prone to corrosion. This corrosion is caused by a reaction with the surrounding environment and the presence of impurities in coal. For this reason, it is necessary to monitor and control corrosion. This study aims to determine the type of corrosion that occurs, corrosion control methods, and the corrosion rate and remaining service life of the conveyor structure.The research was conducted on a 94 meter long conveyor structure which was divided into 3 segments consisting of 25 test points. The methodology in this research is thickness reduction measurement. Measurements were made on the conveyor structure using the Smart Sensor Ultrasonic Thickness Gauge TT 130. Data on nominal thickness, actual thickness and service life are used to calculate the corrosion rate and remaining service life of the conveyor structure. Environmental conditions in the research area based on data from 2015 - 2019 have an average rainfall of 229.26 mm / year, an average relative humidity of 79.44% and an average temperature of 28.16ºC.The type of corrosion that occurs on the conveyor structure is uniform corrosion. The corrosion control method used is the Three Layers System Coating method with primary coating using Seaguard 5000, intermediate coating using Sherglass FF, and top coating using Aliphatic Acrylic Modified Polyurethane Abstrak. Pemindahan material batubara di PT GHI di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan ini biasanya menggunakan Conveyor. Conveyor ini merupakan salah satu alat mekanis yang digunakan untuk memindahkan material dari satu tempat ke tempat lainnya. Struktur Conveyor ini memiliki bahan dasar baja karbon yang mana material ini merupakan material yang rawan terhadap korosi. Korosi ini disebabkan adanya reaksi dengan lingkungan sekitar dan adanya pengotor pada batubara. Untuk itu perlu dilakukan monitoring dan pengendalian korosi. Penelitian ini bertujuan untuk mengetahui jenis korosi yang terjadi, metode pengendalian korosi, dan laju korosi dan sisa umur pakai struktur conveyor. Penelitian dilakukan pada struktur Conveyor sepanjang 94 meter yang terbagi menjadi 3 segmen yang terdiri dari 25 test point. Metodologi dalam penelitian ini adalah pengukuran pengurangan ketebalan. Pengukuran dilakukan pada struktur conveyor menggunakan alat Smart Sensor Ultrasonic Thickness Gauge TT 130. Data tebal nominal, tebal aktual dan umur pakai yang digunakan untuk menghitung corrosion rate serta remaining service Life dari struktur conveyor. Kondisi lingkungan di daerah penelitian berdasarkan data dari tahun 2015 – 2019 memiliki curah hujan rata-rata 229,26 mm/tahun, kelembapan relatif rata-rata 79,44% dan temperatur rata-rata 28,16ºC. Jenis korosi yang terjadi pada struktur conveyor merupakan korosi merata. Metode pengendalian korosi yang digunakan merupakan metode Coating Three Layers System dengan primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating menggunakan Aliphatic Acrylic Modified Polyurethane
Remaining Service Life Discharge Conveyor E pada Tambang Batubara di PT XYZ Kabupaten Bungo, Provinsi Jambi Sandy Renaldi; Elfida Moralista; Noor Fauzi Isniarno
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5617

Abstract

Abstract. Conveyor is a tool that is applied to the mining industry as a tool that supports the process of moving excavated materials such as coal. The structure of the conveyor is made of steel which is subject to corrosion. The disadvantage of corrosion is that it results in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to control and monitor corrosion on the conveyor structure to be observed, so that corrosion can be controlled. The purpose of this research is to determine the type of corrosion, corrosion rate, remaining service life, and control methods. The methodology used in this research is measuring the thickness reduction of the conveyor structure. This research was conducted on a 128 meter long conveyor structure above ground level. Measurement of the thickness of the conveyor structure using the Ultrasonic Thickness Gauge TT 130 at 32 test points. The environmental conditions in the research area are the air temperature in the range of 24,5°C – 26,1°C, while the rainfall ranges from 5,76 mm/year - 7,88 mm/ year. The type of corrosion that occurs in the conveyor structure is uniform corrosion. In controlling this corrosion using a coating method with Seaguard 5000 primer coating, Sherglass FF intermediate coating, and aliphatic acrylic modified polyurethane top coating. The corrosion rate of the conveyor structure ranges from 0.17 - 0.30 mm/year which is included in the good category based on the relative corrosion resistance of steel. Meanwhile, the remaining service life of the conveyor structure ranges from 7,24 - 9,63 years. The service life of the conveyor structure is 8 years, while the design life is 15 years. So it is predicted that 100% can reach its the design life. Abstrak. Conveyor adalah alat yang diaplikasikan pada industri pertambangan sebagai alat yang menunjang dalam proses pemindahan material bahan galian contohnya batubara. Struktur conveyor terbuat dari baja karbon yang dapat mengalami korosi. Kerugian terjadinya korosi yaitu mengakibatkan pengurangan ketebalan struktur conveyor. Oleh karena itu, perlu dilakukannya pengendalian serta monitoring korosi pada struktur conveyor, sehingga korosi dapat dikendalikan. Tujuan dilakukannya penelitian ini untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendaliannya. Metodologi yang digunakan dalam penelitian ini yaitu pengukuran pengurangan ketebalan struktur conveyor. Penelitian ini dilakukan pada struktur conveyor sepanjang 128 meter yang berada di atas permukaan tanah. Pengukuran ketebalan struktur conveyor menggunakan alat Ultrasonic Thickness Gauge TT 130 pada 32 test point. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 24,5°C - 26,1°C, sedangkan curah hujan kisaran 5,76 mm/tahun - 7,88 mm/tahun Jenis korosi yang terjadi pada struktur conveyor adalah korosi merata. Dalam pengendalian korosi ini menggunakan metoda coating dengan primer coating Seaguard 5000, intermediate coating Sherglass FF, dan top coating aliphatic acrylic modified polyurethane. Laju korosi struktur conveyor berkisar antara 0,17 - 0,30 mm/tahun termasuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Sedangkan sisa umur pakai struktur conveyor berkisar antara 7,24 - 9,63 tahun. Umur pakai struktur conveyor yaitu 8 tahun, sedangkan umur desainnya 15 tahun. Sehingga diprediksi sebesar 100% dapat mencapai umur desainnya.
Remaining Service Life Discharge Conveyor E pada Tambang Batubara PT XYZ di Kabupaten Merangin Provinsi Jambi Muhammad Fu'ad; Elfida Moralista; Noor Fauzi Isniarno
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5652

Abstract

Abstract. The Conveyor is a tool to move material from one place to another efficiently. Conveyor structures are made of steel that is subject to corrosion caused by certain conditions such as environmental conditions. Corrosion can cause thickness reduction and reduce the remaining life of the Conveyor structure. In this study, the Conveyor structure consists of 3 segments with a total of 27 Test points along 114 meters. This study aims to determine the type of corrosion, corrosion control, Corrosion Rate, and Remaining Service Life of the Conveyor structure. The research methodology used is to measure the thickness reduction on the Conveyor structure with the Ultrasonic Thickness Gauge TT 130. This research area has environmental conditions, namely air temperature around 26,7OC – 28,4OC, rainfall around 56,50 mm – 482,80 mm, and the highest relative humidity is 89,3%. The type of corrosion that occurs in the Conveyor structure is uniform corrosion. The corrosion control method uses a Coating method with a Thre layer system. The Coating method for Primer Coating uses Seaguard 5000, Intermediate Coating uses Sherglass FF, and Top Coating uses aliphatic acrylic modified polyurethane. Conveyor structure Corrosion Rate ranges from 0,19 - 0,34 mm/year and based on the relative corrosion resistance of steel is included in the good category. The service life of the Conveyor structure is 7 years and the Remaining Service Life is between 6,41 – 8,89 years. So that there are 48% of Test points that are not reach the design life of 15 years. Keywords: Conveyor Structure, Carbon Steel, Coating, Corrosion Rate, Remaining Service Life Abstrak. Conveyor merupakan alat untuk memindahkan suatu material dari satu tempat ke tempat lainnya secara efisien. Struktur Conveyor terbuat dari bahan baja yang rawan mengalami korosi yang disebabkan oleh kondisi lingkungan sekitar. Korosi dapat menyebabkan pengurangan ketebalan dan mengurangi sisa umur pakai struktur Conveyor, sehingga diperlukan adanya kegiatan pengecekan secara berkala terhadap korosi agar dapat mencegah terjadinya korosi. Penelitian ini dilakukan pada struktur Conveyor yang terdiri dari 3 segmen dengan jumlah 27 Test point sepanjang 114 meter. Penelitian bertujuan untuk mengetahui jenis korosi, Pengendalian korosi, laju korosi dan sisa umur pakai pada struktur Conveyor. Metodologi dalam penelitian adalah pengukuran pengurangan ketebalan pada struktur Conveyor dengan alat Ultrasonic Thickness Gauge TT 130. Daerah penelitian memiliki kondisi lingkungan yaitu temperatur udara sekitar 26,7OC – 28,4OC, curah hujan sekitar 56,50 mm – 482,80 mm, dan kelembaban relatif dengan nilai tertinggi yaitu 89,3%. Jenis korosi yang terjadi pada struktur Conveyor adalah korosi merata. Metode pengendalian korosi menggunakan metode Coating dengan sistem Three layers. Metode Coating untuk Primer Coating menggunakan Seaguard 5000, Intermediate Coating menggunakan Sherglass FF, dan Top Coating menggunakan aliphatic acrylic modified polyurethane. Laju korosi struktur Conveyor berkisar antara 0,19 - 0,34 mm/tahun dan berdasarkan ketahanan korosi relatif baja termasuk ke dalam kategori good. Umur pakai struktur Conveyor 7 tahun dan sisa umur pakai berkisar antara 6,41 – 8,89 tahun. Sehingga terdapat 48,15% Test point yang tidak mencapai umur desain yaitu 15 tahun. Kata Kunci: Struktur Conveyor, Laju Korosi, Sisa Umur Pakai
Monitoring Korosi Discharge Conveyor E pada Tambang Batubara PT XYZ di Kabupaten Sarolangun, Provinsi Jambi Aristu Eka Adrian; Elfida Moralista; Zaenal
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5692

Abstract

Abstract. Conveyors structure made from carbon steel are susceptible to corrosion which will reduce the quality of the material. The corrosion that occurs will affect the Remaining Service Life on the conveyor structure. Therefore, the purpose of this research is to determine the type of corrosion, corrosion control that is applied to the conveyor structure, the value of Corrosion Rate and Remaining Service Life.The measurement methodology for the 142 meter long conveyor structure consisting of 4 segments with 32 test points was carried out based on the thickness reduction method. Measurement of the actual thickness of the conveyor structure was carried out using an Ultrasonic Thickness Gauge TT 130. In this study, observations of environmental conditions in 2016-2020 showed that the average air temperature data was 25.34oC, average rainfall was 209.97 mm/year and 86.92% relative humidity. The type of corrosion that occurs on the conveyor structure is uniform corrosion. The corrosion control method applied to the conveyor structure is the coating method with a three-layer system using Seaguard 5000 primer coating, Sherglass FF intermediate coating, and Aliphatic acrylic modified polyurethane top coating. Based on data on reducing the thickness of the conveyor structure with values ranging from 1.31-2.35 mm, a Corrosion Rate is obtained with a value of 0.1871-0.3357 mm/year, based on the table of relative corrosion resistance of steel this value is included in the good category. The service life of the conveyor structure is 7 years with a Remaining Service Life value ranging from 6.58-9.01 years. Therefore there are 14 or 43.75% of the 32 test points which are predicted not to reach the design life of 15 years. Abstrak. Struktur Conveyor berbahan dasar baja karbon rentan mengalami terjadinya korosi yang akan mengurangi kualitas material.. Korosi yang terjadi akan berpengaruh terhadap Remaining Service Life pada struktur conveyor. Maka dari itu tujuan dilakukannya penelitian ini untuk mengetahui jenis korosi, pengendalian korosi yang diaplikasikan pada struktur conveyor, nilai Corrosion Rate dan Remaining Service Life. Metodologi pengukuran pada struktur conveyor sepanjang 142 meter yang terdiri dari 4 segmen dengan 32 test point dilakukan berdasarkan metode pengurangan ketebalan. Pengukuran tebal aktual struktur conveyor dilakukan dengan menggunakan alat Ultrasonic Thickness Gauge TT 130. Pada penelitian ini, pengamatan kondisi lingkungan pada tahun 2016-2020 menunjukan bahwa data temperatur udara rata-rata 25,34oC, curah hujan rata-rata 209,97 mm/tahun dan kelembapan relatif 86,92%. Jenis korosi yang terjadi pada struktur conveyor yaitu korosi merata. Metode pengendalian korosi yang diaplikasikan pada struktur conveyor yaitu metode coating dengan sistem three layer system menggunakan primer coating Seaguard 5000, intermediate coating Sherglass FF, dan top coating Aliphatic acrylic modified polyurethane. Berdasarkan data pengurangan ketebalan struktur conveyor dengan nilai berkisar antara 1,31-2,35 mm, didapatkan Corrosion Rate dengan nilai 0,1871-0,3357 mm/tahun, berdasarkan tabel ketahanan korosi relatif baja nilai tersebut termasuk ke dalam kategori good. Umur pakai struktur conveyor 7 tahun dengan nilai Remaining Service Life berkisar antara 6,58-9,01 tahun. Oleh karena itu terdapat 14 atau 43,75% dari 32 test point diprediksi tidak dapat mencapai umur desainnya yaitu 15 tahun.
Remaining Service Life Discharge Conveyor E pada Tambang Batubara PT XYZ di Kabupaten Tebo, Provinsi Jambi Jossie Indra Saputra; Elfida Moralista; Iswandaru
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.5965

Abstract

Abstract. Carbon steel is the widely used steel as a material for conveyor structures. conveyor structure interacts with the environment can cause corrosion Therefore, monitoring is needed, one of which is by conducting a study on corrosion on the conveyor structure so that the remaining service life of the structure can reach its design life. This study aims to determine the type of corrosion, the applied corrosion control method, the corrosion rate, and the remaining service life of the conveyor structure. The methodology in this research is the method of measuring the thickness reduction of the conveyor structure at 32 observation points along 142 meters above the ground. In this study, observations of environmental conditions included air temperatures ranging from 25.8oC – 26.64oC with an average humidity of 88.5% and rainfall ranging from 42.19 – 437.7 mm.The type of corrosion that occurs in the conveyor structure is uniform corrosion. The corrosion control method applied is the coating method with using Seaguard 5000 for primary coating, Sherglass FF for intermediate coating, Aliphatic acrylic modified polyurethane for top coating. Abstrak. Baja karbon merupakan baja yang banyak digunakan sebagai bahan pembuatan struktur conveyor. struktur conveyor yang berinteraksi dengan lingkungan dapat mengakibatkan terjadinya korosi Oleh karenanya, diperlukan monitoring salah satunya dengan melakukan kajian mengenai korosi pada stuktur conveyor agar sisa umur pakai struktur dapat mencapai umur desainnya. Penelitian ini bertujuan untuk mengetahui jenis korosi, metode pengendalian korosi yang diaplikasikan, laju korosi, dan sisa umur pakai struktur conveyor. Metodologi dalam penelitian ini yaitu metode pengukuran pengurangan ketebalan struktur conveyor pada 32 titik pengamatan sepanjang 142. Pada penelitian ini, pengamatan kondisi lingkungan meliputi temperatur udara berkisar 25.8oC – 26.64 oC dengan kelembaban rata-rata 88,5% dan curah hujan berkisar 42.19 – 437.7 mm. Jenis korosi yang terjadi pada struktur conveyor adalah korosi merata. Metode pengendalian korosi yang diaplikasikan adalah metode coating dengan menggunakan Seaguard 5000 untuk primer coating, Sherglass FF untuk intermediate coating, Aliphatic acrylic modified polyurethane untuk top coating.
Kajian Perubahan Kuantitas Udara pada Sistem Ventilasi Penambangan Emas Underground di Area Penambangan Ciguha PT Antam Tbk, UBPE Pongkor, Kabupaten Bogor, Provinsi Jawa Barat Ahmad Iman Athalah Purnawarman; Sriyanti; Elfida Moralista
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.6167

Abstract

Abstract. In the Ciguha mining area which is located at PT Aneka Tambang Tbk, UBPE Pongkor, Bogor Regency, West Java Province, there is a change in the quantity of air in the mine ventilation system. A decrease in air quantity occurs in the auxiliary fan along with the flexible duct which causes a decrease in the air discharge and there is an air leakage in the area around the main fan which causes the air to come back out. The maximum limit for reducing air discharge determined by the company is 15%. Therefore, it is necessary to conduct research with the aim of knowing the decrease in air flow in the 37 kW auxiliary fan blower with a new fan condition, 22 kW exhaust 40 m long, and the percentage of air leaks in the main fan area. The research was conducted on mine ventilation components in the form of a 37 kW auxiliary fan type blower with a 40 m long flexible duct located on XC-486 and a 22 kW exhaust fan with a 40 m long flexible duct located on XC-481 as well as for a 132 kW main fan located at CGRB-3, 75 kW main fan located at RM-3 CGT and RM-6 CGS Lower. In this study, primary data were used in the form of air velocity, dimensions of the leakage area holes, flexible duct distance, and tunnel dimension and secondary data in the form of air discharge from the fan specifications. Primary and secondary data processing is caried out in order to determine the air discharge which can later be calculated by the percentage of reduction and the area of leakage on the main fan. The percentage for the air reduction for the auxiliary fan with the 37 kW blower fan located at XC-481 which is 23,96%, and for a 22 kW exhaust fan which is a number 33,40% which based on this value, the two auxiliary fans did not meet the standard values determined by the company. The percentage of air leakage around the 132 kW main fan located at CGRB-3 is 0,23%, the 75 kW main fan located at RM-3 CGT is 0,97%, and the 75 kW main fan located at RM-6 CGS is 0,73. Based on this percentage value, the main fan still meets the standards set by the company. Abstrak. Pada area penambangan Ciguha yang berada di PT Aneka Tambang Tbk, UBPE Pongkor, Kabupaten Bogor, Provinsi Jawa Barat terjadi penurunan kuantitas udara pada sistem ventilasi tambang. Penurunan kuantitas udara terjadi pada auxiliary fan beserta flexible duct yang menyebabkan adanya penurunan debit udara dan terdapat kebocoran udara pada area sekitar main fan yang menyebabkan udara keluar kembali. Batas maksimal penurunan debit udara yang ditentukan oleh perusahaan yaitu 15%. Oleh karena itu, perlu dilakukan penelitian dengan tujuan mengetahui penurunan debit udara pada auxiliary fan blower 37 kW dengan kondisi fan baru, exhaust 22 kW sepanjang 40 m, serta persentase kebocoran udara pada area main fan. Penelitian dilakukan pada komponen ventilasi tambang berupa auxiliary fan jenis blower 37 kW dengan panjang flexible duct 40 m yang terletak di XC-486 dan fan exhaust 22 kW dengan panjang flexible duct 40 m yang terletak di XC-481 serta untuk main fan 132 kW yang terletak di CGRB-3, main fan 75 kW yang terletak di RM-3 CGT dan RM-6 CGS Bawah. Pada penelitian ini digunakan data primer berupa kecepatan udara, dimensi lubang area kebocoran, jarak flexible duct, serta dimensi tunnel dan data sekunder berupa peta administrasi, peta topografi, peta geologi, spesifikasi fan. Pengolahan data primer dan sekunder dilakukan untuk mengetahui debit udara yang selanjutnya digunakan untuk menghitung persentase penurunan debit udara serta area kebocoran pada main fan. Persentase penurunan debit udara pada auxiliary fan dengan jenis fan blower 37 kW m yang terletak di XC-481 yaitu sebesar 23,96%, dan untuk fan exhaust 22 kW sebesar 33,40%. Kedua auxiliary fan tersebut tidak memenuhi nilai standar yang ditentukan oleh perusahaan yaitu 15%. Persentase kebocoran udara pada area sekitar main fan 132 kW yang terletak di CGRB-3 yaitu sebesar 0,23%, main fan 75 kW yang terletak di RM-3 CGT sebesar 0,97%, dan main fan 75 kW yang terletak di RM-6 CGS Bawah sebesar 0,73%. Berdasarkan nilai persentase tersebut untuk main fan masih memenuhi standar yang ditentukan oleh perusahaan yaitu 15%.
Monitoring Korosi Discharge Conveyor E pada Tambang Batubara PT GHI di Kabupaten Kotabaru Provinsi Kalimantan Selatan Rizal Andriansyah; Elfida Moralista; Zaenal
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.6843

Abstract

Abstract. Conveyor is a mechanical conveyance used for the coal removal process. The conveyor structure is generally made of carbon steel which is prone to corrosion when reacting with the environment. The corrosion that occurs can lead to a reduction in the thickness of the conveyor structure. Therefore, monitoring and corrosion control are needed, so as to slow down the corrosion rate and reach the design life. The purpose of this research is to determine the type of corrosion that occurs, the corrosion control methods used, Corrosion rate, and Remaining service life.In this study using the research methodology of measuring the thickness reduction of the conveyor structure. The thickness measurement of the conveyance was carried out using the Ultrasonic Gauge TT130 tool on a 95-meter-long conveyor structure divided into 3 segments with 25 test points. The data obtained include nominal thickness, actual thickness, design life of 15 years and service life of 5 years, used to calculate Thickness Required, Corrosion rate, and Remaining service life. The environmental conditions of the study area in a period of 5 years from 2015 to 2019 had an average rainfall of 197.98 mm / year, an average air temperature of 26.91 °C, and an average humidity of 83.62%. Corrosion that occurs in the conveyor structure is evenly corrosion and the corrosion control method applied is a coating with a three-layer system, namely primer coating using Seaguard 5000, intermediate coating using Sherglass FF, and top coating using Aliphatic arcylic modified polyurethane. The corrosion rate that occurs in the conveyor structure ranges from 0.1880-0.3300 mm / year, so based on the relative corrosive resistance of steel is included in the "good" category. The service life of the conveyor structure is 9.43-11.35 years. Thus, 40% of the 25 test points are predicted to not be able to reach the design life, which is 15 years. Abstrak. Conveyor merupakan alat angkut mekanis yang digunakan untuk proses pemindahan batubara. Struktur conveyor pada umumnya berbahan dasar baja karbon yang rentan mengalami korosi apabila bereaksi dengan lingkungan. Korosi yang terjadi dapat menyebabkan pengurangan ketebalan pada struktur conveyor. Oleh karena itu diperlukan monitoring dan pengendalian korosi, sehingga dapat memperlambat laju korosi serta mencapai umur desain. Tujuan dilakukannya penelitian ini untuk mengetahui jenis korosi yang terjadi, metode pengendalian korosi yang digunakan, Corrosion rate, dan Remaining service life.. Pada penelitian ini menggunakan metodologi penelitian pengukuran pengurangan ketebalan struktur conveyor. Pengukuran ketebalan dilakukan menggunakan alat Ultrasonic Gauge TT130 pada struktur conveyor sepanjang 95 meter yang terbagi ke dalam 3 segmen dengan 25 test point. Data yang diperoleh meliputi tebal nominal, tebal aktual, umur desain 15 tahun dan umur pakai 5 tahun, data tersebut kemudian diolah untuk mengetahui Thickness Required, Corrosion rate, dan Remaining service life. Kondisi lingkungan daerah penelitian dalam kurun waktu 5 tahun yang terhitung sejak tahun 2015 sampai tahun 2019 memiliki curah hujan rata-rata sebesar 197,98 mm/tahun, temperatur udara rata-rata 26,91°C, dan kelembapan udara rata-rata 83,62%. Korosi yang terjadi pada struktur conveyor adalah korosi merata dan metode pengendalian korosi yang diaplikasikan adalah coating dengan sistem three layer yaitu primer coating dengan menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating dengan menggunakan Aliphatic arcylic modified polyurethane. Laju korosi yang terjadi pada struktur conveyor berkisar 0,1880-0,3300 mm/tahun, sehingga berdasarkan ketahanan korosif relatif baja termasuk ke dalam kategori “good”. Umur pakai struktur conveyor adalah 9,43-11,35 tahun. Dengan demikian terdapat 40% dari 25 test point yang diprediksi tidak dapat mencapai umur desain, yakni 15 tahun.
Remaining Service Life Discharge Conveyor F pada Tambang Batubara PT XYZ di Kabupaten Sarolangun Provinsi Jambi La Ode Arlin; Elfida Moralista; Noor Fauzi Isniarno
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.6849

Abstract

Abstract. A conveyor is a type of conveyance used to transport mineral materials such as coal. The conveyor's structure is made of carbon steel. However, the conveyor's quality may suffer from corrosion caused by direct contact with coal impurities and their environment. The average air temperature was 27.830C, the average rainfall was 235.34 mm, and the relative humidity was 88.48%. The purpose of this study is to determine the type of corrosion, corrosion control conditions, specifically the coating used, corrosion rate, and the conveyor's remaining service life. Methodology in this research is measuring the thickness reduction of conveyor structure to determine corrosion rate and remaining service life. This research was conducted on a conveyor structure consisting of 4 segments with 32 test points along 142 meters. The actual thickness measurement of the conveyor structure is carried out using Ultrasonic Thickness Gauge TT 130. Type of corrosion that occurs in the conveyor structure is uniform corrosion. Corrosion control method applied to the conveyor structure is coating method. Coating used is a primer coating using Seaguard 5000, intermediate coating using Sherglass FF and top coating using Aliphatic Acrylic Modified Polyurethane. Corrosion rate on conveyor structure is 0.1857 – 0.3357 mm/year and is included in good category based on the relative corrosion resistance of steel. Remaining service life of conveyor structure is 6.580 – 9.138 years and based on the design life, which is 15 years, there are 12 test points or 37.5% test points which are predicted to not reach the design life of conveyor structure. Abstrak. Conveyor merupakan salah satu alat angkut yang digunakan untuk memindahkan material bahan galian seperti batubara. Struktur conveyor yang digunakan berbahan dasar baja karbon. Namun demikian struktur conveyor dapat mengalami penurunan kualitas yang diakibatkan oleh korosi yang terjadi karena kontak langsung dengan pengotor batubara dan lingkungannya. pengamatan kondisi lingkungan meliputi temperatur udara rata-rata 27,830C, curah hujan rata-rata 235,34 mm dan kelembapan relatif 88,48%. Penelitian ini bertujuan untuk mengetahui jenis korosi, kondisi pengendalian korosi yaitu coating yang diaplikasikan, laju korosi, dan sisa umur pakai struktur conveyor. Metodologi dalam penelitian ini adalah pengukuran pengurangan ketebalan struktur conveyor untuk mengetahui laju korosi dan sisa umur pakai. Penelitian ini dilakukan pada struktur conveyor yang terdiri dari 4 segmen dengan 32 test point sepanjang 142 meter. Pengukuran tebal aktual struktur conveyor dilakukan dengan menggunakan alat Ultrasonic Thickness Gauge TT 130. Jenis korosi yang terjadi pada struktur conveyor yaitu korosi merata. Metode pengendalian korosi yang diaplikasikan pada struktur conveyor yaitu metode coating three layer. Coating yang digunakan adalah primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF dan top coating menggunakan Aliphatic Acrylic Modified Polyurethane. Laju korosi pada struktur conveyor yaitu 0,1857 – 0,3357 mm/tahun dan termasuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Sisa umur pakai struktur conveyor yaitu 6,580 – 9,138 tahun dan berdasarkan umur desainnya yaitu 15 tahun maka terdapat 12 test point atau 37,5% test point yang diprediksi tidak dapat mencapai umur desain struktur conveyor.
Monitoring Korosi Discharge Conveyor F Pada Tambang Batubara PT GHI Di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan Muhammad Arib Nazhir; Elfida Moralista; Iswandaru
Bandung Conference Series: Mining Engineering Vol. 3 No. 1 (2023): Bandung Conference Series: Mining Engineering
Publisher : UNISBA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29313/bcsme.v3i1.7019

Abstract

Abstract. Conveyor is a tool that is applied to the mining industry as a tool that supports the process of moving excavated materials such as coal. The structure of the conveyor is made of steel which is subject to corrosion. The disadvantage of corrosion is that it results in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to control and monitor corrosion on the conveyor structure to be observed, so that corrosion can be controlled. The purpose of this research is to determine the type of corrosion, corrosion rate, remaining service life, and control methods. The methodology used in this study is measuring the thickness reduction of the conveyor structure. This research was conducted on a conveyor structure of 90 meters above ground level. Measurement of the thickness of the conveyor structure using the Ultrasonic Thickness Gauge TT 130 at 25 observation points. The environmental conditions in the research area are the air temperature in the range of 26.4 oC-29.5oC, then for average air humidity range of 72%-88.2%,while for the rainfall with an average range of 2,410-3,648.2 mm/tahun. The type of corrosion that occurs in the conveyor structure is uniform corrosion. In controlling this corrosion using a three layers coating method with Seaguard 5000 primer coating, Sherglass FF intermediate coating, and aliphatic acrylic modified polyurethane top coating. The corrosion rate of the conveyor structure ranges from 0.1867-0.337 mm/year which is included in the good category based on the relative corrosion resistance of steel. Meanwhile, the remaining service life of the conveyor structure ranges from 6.56-10.06 years. The service life of the conveyor structure is 6 years, while the design life is 15 years. Based on the calculation of the remaining service life of the conveyor structure at 25 observation points, then obtained of 40.00% predicted to can’t reach his the design life. Abstrak. Conveyor adalah alat yang diaplikasikan pada industri pertambangan sebagai alat yang menunjang dalam proses pemindahan material bahan galian contohnya batubara. Struktur conveyor terbuat dari baja yang dapat mengalami korosi. Kerugian terjadinya korosi yaitu mengakibatkan pengurangan ketebalan struktur conveyor. Oleh karena itu, diperlukan pengendalian serta monitoring korosi pada struktur conveyor, sehingga korosi dapat dikendalikan. Tujuan dilakukannya penelitian ini adalah untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendaliannya. Metodologi yang digunakan dalam penelitian ini yaitu pengukuran pengurangan ketebalan struktur conveyor. Penelitian ini dilakukan pada struktur conveyor sepanjang 92 meter yang berada di atas permukaan tanah. Pengukuran ketebalan struktur conveyor menggunakan alat Ultrasonic Thickness Gauge TT 130 pada 25 test point. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 26,4 oC-29,5oC, lalu untuk kelembapan udara rata-rata kisaran 72%-88,2%, sedangkan curah hujan dengan rata-rata kisaran 2.410-3.648,2 mm/tahun. Jenis korosi yang terjadi pada struktur conveyor adalah korosi merata. Dalam pengendalian korosi ini menggunakan metoda coating three layers dengan primer coating Seaguard 5000, intermediate coating Sherglass FF, dan top coating aliphatic acrylic modified polyurethane. Laju korosi struktur conveyor berkisar antara 0,1867-0,3367 mm/tahun termasuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Sedangkan sisa umur pakai struktur conveyor berkisar antara 6,56-10,06 tahun. Umur pakai struktur conveyor yaitu 6 tahun, sedangkan umur desainnya 15 tahun. Berdasarkan dari hasil perhitungan sisa umur pakai struktur conveyor pada 25 test point, didapatkan 40,00% yang diprediksikan tidak dapat mencapai umur desainnya.