Redesain Ruang Ibadah Masjid Agung Pati Berdasarkan Performa Kenyamanan Termal, Visual, Dan Akustik ashim furqoni; Eddy Prianto; Agung Budi Sardjono; Gagoek Hardiman
RUAS Vol 20, No 2 (2022)
Publisher : RUAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/ub.ruas.2022.020.02.4

Abstract

Architecture is a place to move comfortably. The mosque is the four worshippers of muslims who should have an optimal level of comfort. This study aims to examine the comfort performance of the prayer room of the Great Mosque of Pati based on applicable theories and standards, then design based on the results of a comfort study to get a prayer room design that meets the comfort criteria for its users. The research was conducted by dividing the prayer room into 16 points. At each point, 3 measurements are carried out, namely thermal, lighting, and noise measurements both in the morning, afternoon, afternoon, and evening. From the measurement results, it is known that the average temperature in the worship room is 27.4 °C, meaning that the temperature is hotter than the standard of comfort (<27 °C). The average exposure is 103.5 lux, meaning the lighting is darker than required (200 lux). The average noise is 61.7 dB, meaning that the situation inside the worship room is noisier than the maximum noise level allowed for the worship space (55 dB).
Kajian Sistem Penghawaan terhadap Kenyamanan Termal pada Rumah Produksi Tenun Bukan Mesin Astrihasna Shafa; Gagoek Hardiman; Wahyu Setia Budi
ARSITEKTURA Vol 21, No 1 (2023): Arsitektura : Jurnal Ilmiah Arsitektur dan Lingkungan Binaan
Publisher : Universitas Sebelas Maret Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20961/arst.v21i2.63117

Abstract

Thermal comfort is essential when designing a building that will serve as a work activities place. A comfortable work environment will increase worker productivity. This study is a form of correction to non-machine weaving production house to obtain an optimal ventilation system for achieving thermal comfort. This research uses quantitative in non-machine weaving production house in Pekalongan. The data collected are thermal measurement data and air intensity in the workspace directly from morning to evening for two days. Measurements using a thermometer, hygrometer, and hot wire anemometer. Measurements were carried out in two conditions to compare the air intensity in the workspace. The measurement results will be analyzed using the recommended standards. The observations show that natural ventilation is not optimal in a horizontal building and an open space with an inner court. The fan's type and shape affect the airflow arrangement in the room.
Redesain Ruang Ibadah Masjid Agung Pati Berdasarkan Performa Kenyamanan Termal, Visual, Dan Akustik ashim furqoni; Eddy Prianto; Agung Budi Sardjono; Gagoek Hardiman
RUAS Vol. 20 No. 2 (2022)
Publisher : Departemen Arsitektur Fakultas Teknik Universitas Brawijaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/ub.ruas.2022.020.02.4

Abstract

Architecture is a place to move comfortably. The mosque is the four worshippers of muslims who should have an optimal level of comfort. This study aims to examine the comfort performance of the prayer room of the Great Mosque of Pati based on applicable theories and standards, then design based on the results of a comfort study to get a prayer room design that meets the comfort criteria for its users. The research was conducted by dividing the prayer room into 16 points. At each point, 3 measurements are carried out, namely thermal, lighting, and noise measurements both in the morning, afternoon, afternoon, and evening. From the measurement results, it is known that the average temperature in the worship room is 27.4 °C, meaning that the temperature is hotter than the standard of comfort (<27 °C). The average exposure is 103.5 lux, meaning the lighting is darker than required (200 lux). The average noise is 61.7 dB, meaning that the situation inside the worship room is noisier than the maximum noise level allowed for the worship space (55 dB).