STUDI EKSPERIMENTAL NATURAL REFIGERANT DENGAN VARIASI DIAMETER TiT-HEAT EXCHANGER TERHADAP REFRIGERATOR PERFORMANCE Ariyano; Apri Wiyono; Rifqi Rahmadiansyah; Rani Anggrainy; Dibyo Setiawan; Zeqy Zulhaqy
Jurnal Permadi : Perancangan, Manufaktur, Material dan Energi Vol 5 No 03 (2023): JURNAL PERMADI: PERANCANGAN, MANUFAKTUR, MATERIAL DAN ENERGI
Publisher : Universitas Nusa Putra

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52005/permadi.v5i03.113

Abstract

ABSTRACT Almost all households in Indonesia use a refrigerator as a place to store food that is more durable. But behind these needs, refrigerators are identified as one of the household appliances that use high electrical energy. Therefore, this study aims to examine the use of Tube in Tube Heat Exchanger (TiTHX) with refrigerant R290 in the refrigerator system to reduce household electricity consumption. This research was conducted experimentally by varying the 3 diameter ratios on TiTHX. The results showed that the use of TiTHX with the most optimum value was obtained at the variation diameter ¼ : ½ increasing refrigerator performance by 3.7%. and also reduce the consumption of electricity costs up to Rp. 17,544.44 per month. This is because the difference between the evaporation pressure and condensation pressure is smaller in systems using TiTHX which then results in lower compression work.
Studi Perencanaan Ulang Perpipaan Sistem Filtrasi Air Skala Rumah Tangga Dibyo Setiawan; Jakariya; Rani Anggrainy; Linda Wijayanti; Melisa Mulyadi
Jurnal Permadi : Perancangan, Manufaktur, Material dan Energi Vol 5 No 03 (2023): JURNAL PERMADI: PERANCANGAN, MANUFAKTUR, MATERIAL DAN ENERGI
Publisher : Universitas Nusa Putra

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52005/permadi.v5i03.120

Abstract

Clean water is a primary necessity for human survival, but due to limited access to clean water sources, wells are often used to meet this need. However, water from wells cannot be used directly because its quality varies depending on the soil conditions. Due to these differences, a filtration system needs to be installed in the treatment of raw water from the well. In the process, well water, after being processed through the filtration system, experiences a decrease in flow rate before being stored in water tanks. This creates a problem, namely excessive electricity consumption and insufficient water flow for household use. In this research, the researcher attempts to implement the SNI (Indonesian National Standard) standards in household-scale clean water treatment, whereas previous research focused more on water quality testing. The objectives of this research are to reduce electricity consumption and increase water flow to meet household needs. Regarding the research method, the researcher conducted a literature review, data collection, pre-improvement testing, redesigned pipeline planning, performance testing of the improvement results, and analysis of the outcomes. The results of this research show that for the 1-liter container testing, the required time has increased, with the fastest time being 6.4 seconds and the slowest being 6.7 seconds, compared to the initial testing, which had a range of 13.2 seconds to 13.6 seconds. As for electricity consumption, there has been a significant decrease, from 2.76 A in the initial testing to 1.76 A, resulting in an average power consumption of 200.3 watt, compared to the previous 603.7 watt.