Jurnal Ilmiah Mahasiswa Veteriner
Vol 4, No 2 (2020): FEBRUARI-APRIL

NILAI SERUM GLUTAMIC OXALOACETIC TRANSAMINASE (SGOT) DAN SERUM GLUTAMIC PYRUVIC TRANSAMINASE (SGPT) KELINCI SETELAH IMPLAN PLATE BERBAHAN LOGAM (THE VALUE OF SERUM GLUTAMIC OXALOACETIC TRANSAMINASE (SGOT) AND GLUTAMIC PYRUVIC TRANSAMINASE (SGPT) OF RABBITS AFTER METAL PLATES IMPLANT)

Anta Rezky Sitepu (Program Studi Pendidikan Dokter Hewan, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)
Erwin Erwin (Laboratorium Klinik, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)
Muhammad Hasan (Laboratorium Klinik, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)
Sugito Sugito (Laboratorium Klinik, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)
Al Azhar (Laboratorium Biokimia, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)
Razali Razali (Laboratorium Kesehatan Masyarakat Veteriner, Fakultas Kedokteran Hewan, Universitas Syiah Kuala)



Article Info

Publish Date
27 Apr 2020

Abstract

ABSTRAK                Penelitian ini bertujuan untuk mengetahui perubahan nilai Serum Glutamic Oxaloacetic Transaminase (SGOT) dan Serum Glutamic Pyruvic Transaminase (SGPT) kelinci setelah implan plate berbahan logam. Penelitian ini menggunakan 6 ekor kelinci yang dibagi menjadi 2 kelompok. Kelompok 1 diimplan plate berbahan tantalum dan kelompok 2 diimplan plate berbahan besi. Pengambilan darah melalui vena auricularis dilakukan pada hari ke 0, 7, 14, 28, dan 56. Hasil penelitian menunjukkan nilai SGOT dan SGPT meningkat pada beberapa hari pertama pengamatan dan menurun kembali pada beberapa hari terakhir pengamatan yang masih dalam batas normal. Penggunaan implan plate tantalum dan plate besi alternatif menyebabkan perubahan nilai SGOT dan SGPT pada beberapa hari pengamatan.Kata Kunci : SGOT, SGPT, Plate, Tantalum, Besi ABSTRACT            This study aims to determine changes in Serum Glutamic Oxaloacetic Transaminase (SGOT) and Glutamic Pyruvic Transaminase (SGPT) values of rabbit after a metal implant plate. This study used 6 rabbits divided into 2 groups. Group one implanted a plate made from tantalum and group two implanted with alternative iron plates. Blood collection through the auricular vein was carried out on days 0, 7, 14, 28, and 56. The results showed that the value of SGOT and SGPT increased in several days of observation and increased again on the final day which was still within normal limits. The use of tantalum implants and alternative iron plates causes changes in the value of SGOT and SGPT on several days of observation.Keyword : SGOT, SGPT, Plate, Tantalum, Iron

Copyrights © 2020






Journal Info

Abbrev

FKH

Publisher

Subject

Veterinary

Description

Jurnal Ilmiah Mahasiswa Veteriner merupakan media elektronik yang digunakan sebagai wadah penyebaran hasil-hasil penelitian dari skripsi/tugas akhir mahasiswa Fakultas Kedokteran Hewan Universitas Syiah Kuala yang ditulis bersama dengan dosen pembimbingnya. Naskah/artikel yang diterbitkan telah ...