Jurnal Teknik Sipil
Vol 20, No 2 (2013)

Studi Numerik Usulan Jarak Pengaku Badan Diagonal Link Geser pada Struktur Baja Eccentrically Braced Frame Type–D

Kurdi, Kurdi ( Program Doktor Bidang Keahlian Rekayasa Struktur, Fakultas Teknik Sipil dan Lingkungan - Institut Teknologi Bandung.)
Budiono, Bambang ( Kelompok Keahlian Rekayasa Struktur, Program Studi Teknik Sipil, Fakultas Teknik Sipil dan Lingkungan - Institut Teknologi Bandung, Jl. Ganesa No.10 Bandung 40132.)
Yurisman, Yurisman ( Staf Pengajar Politeknik Negeri Padang, Kampus Politeknik Limau Manis Padang.)



Article Info

Publish Date
23 Aug 2016

Abstract

Abstrak. Struktur portal baja Eccentrically Braced Frame type–D (EBF-D) dengan link geser berpengaku badan dimodelkan dalam penelitian ini menggunakan perangkat lunak MSC Nastran. Pembebanan diberikan secara monotonik dan siklik dengan kontrol perpindahan. Model struktur link geser berpengaku badan vertikal didesain dengan jarak pengaku sesuai dengan ketentuan AISC 2005. Model yang lain didesain menggunakan link geser berpengaku badan diagonal dengan jarak pengaku antara 30tw-d/5 sampai dengan panjang link (e) atau didesain tidak memenuhi syarat AISC 2005. Parameter  konfigurasi pengaku badan diagonal, jarak pengaku (a), panjang link (e), tebal badan link (tw), tebal sayap link (tf) dan tebal pengaku vertikal (tsv) maupun diagonal (tsd) diteliti dalam penelitian ini. Hasil penelitian menunjukkan kinerja struktur portal EBF-D link geser berpengaku badan diagonal lebih baik dibandingkan dengan berpengaku vertikal dari segi kekuatan, kekakuan,daktilitas maupun penyerapan energi dissipasi akibat beban gempa. Jarak optimal antara pengaku badan vertikal yang menggunakan pengaku diagonal diusulkan sebesar 1,6 (30tw-d/5) dengan ketebalan minimum pengaku badan diagonal 5,5 mm atau sama dengan tebal badan dan 8 mm untuk tebal minimum pengaku vertikal. Abstract. Eccentrically braced frame type-D (EBF-D) of steel structure with shear link web stiffener is modeled in this study using MSC Nastran software. The monotonic and cyclic loading is given under the displacement control. The shear link structure model with the vertical web stiffeners are designed with the spacing accordance to the provisions of AISC 2005. Other model is designed with shear link web stiffener diagonal with spacing between 30tw-d/5 to length of link (e) or designed ineligible to AISC 2005. The parameters of EBF-D with web stiffeners will be meansured to : configuration of the web stiffeners, the space of stiffener (a), length of the link (e), thickness of web link (tw), thickness of flange link (tf) and the thickness vertical web stiffeners (tsv) and diagonal (tsd). The results show that the performance of the portal structure of EBF-D shear link diagonal of web stiffener is better than vertical web stiffener both in terms of strength, stiffness, ductility and the absorption of energy dissipation due to earthquake loads. Optimal space between vertical web stiffeners using diagonal web stiffener is 1.6 by (30tw-d/5) with minimumthickness of diagonal web stiffener is 5.5 mm or equal which thickness web link and thickness minimum vertical web stiffeners is 8 mm.

Copyrights © 2013






Journal Info

Abbrev

JTS

Publisher

Subject

Civil Engineering, Building, Construction & Architecture

Description

Jurnal Teknik Sipil merupakan jurnal ilmiah yang diterbitkan berkala setiap tiga bulan, yaitu April, Agustus dan Desember. Jurnal Teknik Sipil diterbitkan untuk pertama kalinya pada tahun 1990 dengan membawa misi sebagai pelopor dalam penerbitan media informasi perkembangan ilmu Teknik Sipil di ...