cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota semarang,
Jawa tengah
INDONESIA
BERKALA FISIKA
Published by Universitas Diponegoro
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
BERKALA FISIKA adalah jurnal saintifik yang diterbitkan secara periodik 3 bulanan. Jurnal ini memuat kajian-kajian Fisika baik kajian teoretik maupun hasil eksperimen. Jurnal ini juga memberi ruang yang luas bagi kajian – kajian aplikasi fisika dalam bidang teknologi, ilmu-ilmu hayati dan kedokteran.
Arjuna Subject : -
Articles 346 Documents
KOMPARASI ENTRANCE SURFACE AIR KERMA (ESAK) DENGAN SOFTWARE CALDOSE_X DAN METODE TUBE OUTPUT PADA PASIEN THORAX DEWASA DALAM PEMERIKSAAN RADIOGRAFI UMUM BERDASARKAN DATA SI-INTAN Anugrah Rahma Ari Wiganti; Eko Hidayanto; Indras Marhaendrajaya; Pandji Triadyaksa
BERKALA FISIKA Vol 25, No 4 (2022): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Kuantitas  operasional  dosimetri  didasarkan  pada  pengukuran  Entrance  Surface  Air  Kerma (ESAK),  baik  secara  langsung  dengan  thermoluminescence  dosimeter  (TLD)  maupun  tidak langsung dengan memanfaatkan keluaran radiasi pesawat sinar-X.  Namun, CALDose_X dan juga  metode  Tube  Output  mampu  melakukan  perhitungan  dosis  menggunakan  persamaan standar.  Penelitian  ini  bertujuan  untuk  menghitung  ESAK  pada  pemeriksaan  Thorax  radiografi umum  proyeksi  Anterior  Posterior  (AP)  dan  Posterior  Anterior  (PA)  berdasarkan  data  SI- INTAN  dengan  perangkat  lunak  CALDose_X  dan  metode  tube  output  serta  menganalisis perhitungan  ESAK  tersebut  dengan  nilai  Diagnostic  Reference  Level  (DRL).  Data  penelitian bersumber  pada  basis  data  SI-INTAN  Bapeten  yang  berupa  data  survei  pasien  dan  data  keluaran radiasi pada salah satu rumah sakit di Jawa Timur yaitu sebanyak 76 data proyeksi AP dan 111 data proyeksi  PA.  Data  diolah  menggunakan  CALDose_X  dan  metode  tube  output  serta  diuji menggunakan uji normalitas dan uji Wilcoxon. ESAK pada pemeriksaan thorax dewasa radiografi umum rumah sakit X proyeksi AP dengan CALDose_X sebesar 0,34±0,055 mGy dan metode tube  output  sebesar  0,33±0,059  mGy.  Sedangkan  proyeksi  PA  dengan  Caldose-X  yaitu sebesar  0,31±0,13  dan  metode  tube  output  sebesar  0,30±0,13  mGy.  ESAK  pemeriksaan Thorax  di  rumah  sakit  X  pada  CALDose_X  menunjukkan  tidak  ada  perbedaan  yang signifikan dengan metode tube output dan nilainya lebih rendah daripada DRL Indonesia.
ANALISIS FENOMENA ELEKTROHIDRODINAMIK MENGGUNAKAN PLASMA LUCUTAN KORONA DC POSITIF DENGAN KONFIGURASI ELEKTRODA MATA PAHAT DAN TITIK TENGAH-BIDANG PADA MINYAK KELAPA SAWIT Charis Munajib; Asep Yoyo Wardaya; Zaenul Muhlisin; Isnain Gunadi
BERKALA FISIKA Vol 25, No 4 (2022): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Research  has  been  carried  out  on  the  analysis  of  I-V  characteristic  curves  and electrohydrodynamic phenomena using palm oil with a positive DC corona discharge generator with Chisel Eye and Mid-Field electrode configurations. This study aimed to obtain the effect of several  variations  used  on  the  characteristic  curve  and  distribution  of  ion  winds  on electrohydrodynamic phenomena. This research was conducted with 6 variations of the size of the dimensions of active electrodes and variations in the distance between the electrodes (c) 0.5 cm, 1 cm, 1.5 cm, and 2 cm. In the study of the I-V characteristic curve, the results show that with the increase in the applied voltage, the stronger the current produced will increase. At electrode D and a distance of 0.5 cm, the circuit is given a voltage of 5.32 kV produces a current of 10.5 A, whereas if the circuit is given a voltage of 6.34 kV it produces a current of 27.5 A. In the study of the analysis of electrohydrodynamic phenomena, it was found that if the variation used changed it would affect the diameter of the deformation of the palm oil in the form of a circle. At electrode D, at a distance of 0.5 cm with a voltage of 7.14 kV it produces a circular oil deformation diameter of  2.7  cm,  while  at  a  distance  of  1  cm  with  a  voltage  of  11.23  kV  produces  a  circular  oil deformation diameter of 5.5 cm.
PENENTUAN KESERAGAMAN RESPON DAN FAKTOR KOREKSI TLD – 100 (LiF:Mg,Ti) TERHADAP RADIASI SINAR-X Syaphira Faza Nurulita; Wahyu Setia Budi; Eko Hidayanto; Nunung Nuraeni
BERKALA FISIKA Vol 26, No 1 (2023): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

One  of  the  body  tissues  of  radiation  workers  that  is  very  sensitive  to  exposure  to  X-ray radiation  is  the  eye  lens.  Damage  experienced  by  the  lens  of  the  eye  exposed  to  X-ray radiation  can  develop  until  blindness  occurs  due  to  cataracts.  The  use  of  a Thermoluminescence  Dosemeter  (TLD)  can  control  the  external  radiation  dose  received  by the  eyepiece  of  radiation  workers.  In  this  study  there  are  several  objectives,  namely  to determine  the  uniformity  of  the  response  to  TLD-100  (LiF:Mg,Ti)  to  determine  the characteristics of TLD-100 (Lif:Mg,Ti) which is used to measure the radiation dose of the eye lens  and  determine  the  TLD-100  correction  factor  on  X-ray  radiation  to  obtain  an  accurate dose  of  TLD-100  readings  in  the  eyepiece.  The  determination  of  the  uniformity  of  reading response and correction factor of TLD-100 (LiF:Mg,Ti) was carried out on the surface of the water  phantom  using  conventional  X-ray  radiation  sources  with  variations  in  voltage (60;70;80) kV at a distance of 100 cm and a wide field. used is 26 x 26 cm. From the results obtained for determining the uniformity of the response of TLD-100 at voltage (60;70;80) kV using  Statistical  Process  Control  (SPC)  analysis  it  can  be  concluded  that  TLD-100  has  a uniform response because it is between the Lower Warning Limit (LWL) and Upper Warning Limit  (UWL).  However,  according  to  ISO  21909  at  a  voltage  of  60  kV  it  is  necessary  to  re- illuminate  because  the  response  variation  value  obtained  is  40.95%  exceeding  the  specified response variation value limit which is not more than 20% while at a voltage of 70 kV with a response  value  of  20.05%  and  80  kV  with  a  response  variation  value  of  13.93%  did  not exceed  the  predetermined  limits  while  the  results  of  determining  the  TLD-100  correction factor (LiF:Mg,Ti) for each voltage decreased in the range of 0.753 to 0.576. The correction factor at a voltage of 60 kV to 80 kV does not reach the ideal correction factor because the voltage  used  for  calibration  uses  low  energy  while  the  calibration  used  is  for  calibration  at high voltages.
RANCANG BANGUN SISTEM DATA LOGGER DAN MONITORING UNTUK INSTALASI PANEL SURYA GRID TIE (GTI) INVERTER 600 W DENGAN INTERFACING BLYNK Rafly Akhsani Taqwin; Dista Yoel Tadeus; Fakhruddin Mangkusasmito; Ari Bawono Putranto
BERKALA FISIKA Vol 26, No 1 (2023): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Solar  energy  is  an  inexhaustible  source  of  renewable  energy.  Indonesia,  which  is  a  tropical country  that  is  crossed  by  the  equator,  has  a  fairly  high  solar  intensity  per  year.  With  this potential, it is necessary to process or develop the alternative energy. One way to develop this potential is to use solar panels that can convert solar energy into electrical energy. In this study, we developed a data logger system design tool for the installation of an Arduino-based 600 W inverter grid tie (GTI) solar panel. Nowadays, observation or monitoring still uses conventional or  manual  methods.  Therefore,  in  making  this  task  we  made  a  voltage,  current,  and  power monitoring tool on a solar panel that functions as a current, voltage and power sensor with the Arduino Mega microcontroller as an output data store which will be communicated via Android. The results of the data will be analyzed by calculating the break even point (BEP) to determine the feasibility of procuring On-Grid solar panel systems. From the BEP calculation results, the average energy supply from solar panels is 5% or every month solar panels can reduce costs by Rp.42,000. From these results it is known that the value of the BEP from the procurement of On-Grid solar panels can be achieved for 7 years and 4 months, only then it will be profitable.
ANALISIS MODULATION TRANSFER FUNCTION (MTF) DAN CONTRAS-TO-NOISE RATIO (CNR) UNTUK OPTIMASI KUALITAS CITRA CT SCAN Mutiara Fatimah Azhara; Syamsir Dewang; Sri Dewi Astuty; Ulfah Rosyidah; Bannu Abdul Samad
BERKALA FISIKA Vol 26, No 1 (2023): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu parameter utama dalam kualitas citra CT scan untuk menegakkan diagnosa adalah   resolusi  kontras  tinggi  (Modulation  Transfer  Function,  MTF)  dan  resolusi  kontras  rendah (Contrast-to-Noise  Ratio,  CNR).  MTF  dan  CNR  menjadi  kriteria  penting  untuk membandingkan protokol dosis tinggi dan dosis rendah, yang bergantung pada karakteristik obyek  yang  menjadi  target.  MTF  menghitung  jumlah  keburaman  (noise)  dan  kontras  pada frekuensi  spasial  sedangkan  CNR  menampilkan  objek  dalam  ukuran  2-3  mm  yang  memiliki perbedaan densitas. Penelitian ini menggunakan fantom AAPM sebagai obyek dengan variasi arus tabung dan tebal irisan. Citra dianalisis dengan software Radiant DICOM dan IndoQCT. Pengukuran  dilakukan  dengan  dua  variasi  yaitu  arus  tabung  100,  130  dan  150  mA  pada tegangan  tabung  80  kV  dan  tebal  irisan  2,5  mm,  sedangkan  untuk  variasi  tebal  irisan  1,25; 3.75;  dan  5  mm  pada  tegangan  tabung  80  kV  dan  arus  tabung  125  mA.  Hasil  penelitian diperoleh  nilai  MTF  masing-masing  variasi  arus  tabung  berturut-turut  0,7  line/mm;  0,7 line/mm;  dan  0,8  line/mm.  Nilai  MTF  masing-masing  variasi  tebal  irisan  sama  yaitu  0,7 line/mm.  Nilai  CNR  terhadap  variasi  arus  tabung  sebesar  2,548;  3,016;  dan  3,482  serta terhadap  variasi  tebal  irisan  diperoleh  2,308;  2,613;  dan  2,735.  Semakin  besar  nilai  arus tabung dan tebal irisan, maka nilai MTF semakin tinggi demikian pula untuk nilai CNR.
ANALISIS LAJU DOSIS KELUARAN PESAWAT SINAR-X FLUOROSKOPI DUAL FUNGSI DI RS WAHIDIN SUDIROHUSODO MAKASSAR Nur Hikmah Indah; Syamsir Dewang; Sri Dewi Astuty
BERKALA FISIKA Vol 26, No 1 (2023): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian  ini  bertujuan  untuk  menganalisis  kinerja  generator  tabung  pesawat  X-Ray Fluoroscopy  Dual  Function  Merk  APELEM  S.A  di  instalasi  radiologi  RSUP  Wahidin Sudirohusodo Makassar dalam aspek laju dosis ESD tipikal, laju dosis maksimum di udara dan laju dosis permukaan Image Intensifier. Analisis dilakukan berdasarkan indikator perubahan faktor eksposi dan pemilihan mode fungsi pesawat. Beberapa parameter yang menjadi variabel pendukung  adalah  uji  akurasi  tegangan,  uji  reproduksibilitas  keluaran  radiasi,  uji  linieritas kuat  arus  terhadap  keluaran  radiasi.  Hasil  yang  diperoleh  menunjukkan  pada  akurasi tegangan, nilai koefisien variasi (CV) tegangan 65, 75 dan 85 berturut-turut diperoleh 0,31%, 2,08% dan 2,21%. Uji reproduksibilitas menunjukkan hasil terhadap variasi tegangan sebesar 0,0048; terhadap variasi waktu eksposi sebesar 0,0314 dan terhadap variasi keluaran radiasi sebesar  0,0105.  Hasil  analisis  laju  dosis  pada  tiga  parameter  yaitu  laju  dosis  ESD  tipikal diperoleh nilai maksimum sebesar 0,0038 mGy/s, laju dosis maksimum di udara sebesar 0,1248 mGy/s  serta  laju  dosis  permukaan  Image  Intensifier  didapatkan  0,0219  µGy/s.  Semua parameter  yang  diuji  pada  pesawat  X-Ray  Fluoroscopy  Dual  Function  Merk  APELEM  S.A sesuai standar lolos uji yang ditetapkan dalam Perka BAPETEN No. 2 Tahun 2022, sehingga dapat disimpulkan pesawat dalam kondisi layak untuk digunakan secara rutin.

Filter by Year

2006 2023


Filter By Issues
All Issue Vol 26, No 1 (2023): Berkala Fisika Vol 25, No 4 (2022): Berkala Fisika Vol 25, No 2 (2022): Berkala Fisika Vol 24, No 4 (2021): Berkala Fisika Vol 24, No 3 (2021): Berkala Fisika Vol 24, No 1 (2021): Berkala Fisika Vol 23, No 4 (2020): Berkala Fisika Vol 23, No 3 (2020): Berkala Fisika Vol 23, No 2 (2020): Berkala Fisika Vol 23, No 1 (2020): Berkala Fisika Vol 22, No 4 (2019): Berkala Fisika Vol. 22 No. 4 Tahun 2019 Vol 22, No 3 (2019): Berkala Fisika Vol. 22 No. 3 Tahun 2019 Vol 22, No 2 (2019): Berkala Fisika Vol. 22 No. 2 Tahun 2019 Vol 22, No 1 (2019): Berkala Fisika Vol. 22 No. 1 Tahun 2019 2015: Berkala Fisika Vol. 18 No. 4 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 3 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 2 Tahun 2015 2015: Berkala Fisika Vol. 18 No. 1 Tahun 2015 2014: Berkala Fisika Vol. 17 No. 4 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 3 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 2 Tahun 2014 2014: Berkala Fisika Vol. 17 No. 1 Tahun 2014 Vol 16, No 4 (2013): Berkala Fisika Vol 16, No 3 (2013): Berkala Fisika Vol 16, No 2 (2013): Berkala Fisika Vol 16, No 1 (2013): Berkala Fisika Vol 15, No 4 (2012): Berkala Fisika Vol 15, No 3 (2012): Berkala Fisika Vol 15, No 2 (2012): Berkala Fisika Vol 15, No 1 (2012): Berkala Fisika Vol 11, No 2 (2008): Berkala Fisika Vol 14, No 4 (2011): Berkala Fisika Vol 14, No 3 (2011): Berkala Fisika Vol 14, No 2 (2011): Berkala Fisika Vol 14, No 1 (2011): Berkala Fisika Vol 13, No 4 (2010): Berkala Fisika Vol 13, No 3 (2010): Berkala Fisika Vol 13, No 2 (2010): Berkala Fisika Vol 13, No 2 (2010): Berkala Fisika, Edisi Khusus Vol 13, No 1 (2010): Berkala Fisika Vol 12, No 4 (2009): Berkala Fisika Vol 12, No 3 (2009): Berkala Fisika Vol 12, No 2 (2009): Berkala Fisika Vol 12, No 1 (2009): Berkala Fisika Vol 11, No 4 (2008): Berkala Fisika Vol 11, No 3 (2008): Berkala Fisika Vol 11, No 1 (2008): Berkala Fisika Vol 10, No 4 (2007): Berkala Fisika Vol 10, No 3 (2007): Berkala Fisika Vol 10, No 2 (2007): Berkala Fisika Vol 10, No 1 (2007): Berkala Fisika Vol 9, No 4 (2006): Berkala Fisika Vol 9, No 3 (2006): Berkala Fisika Vol 9, No 2 (2006): Berkala Fisika Vol 9, No 1 (2006): Berkala Fisika More Issue