cover
Contact Name
Ummy Mardiana Ramdan
Contact Email
joimedlabs.aiptlmi@gmail.com
Phone
+6281223433385
Journal Mail Official
joimedlabs.aiptlmi@gmail.com
Editorial Address
Jl. Arteri JORR Jatiwarna Pondok Melati, Bekasi, Jawa Barat, Indonesia Kode Pos: 17415
Location
Unknown,
Unknown
INDONESIA
Journal of Indonesian Medical Laboratory and Science (JoIMedLabS)
ISSN : 27750108     EISSN : 27742504     DOI : -
Core Subject : Health, Science,
Journal of Indonesian Medical Laboratory and Science (JoIMedLabS) merupakan jurnal AIPTLMI (Asosiasi Institusi Pendidikan Tinggi Teknologi Laboratorium Medik Indonesia) yang dapat diakses secara terbuka (open acces) yang berfokus pada pengembangan ilmu pengetahuan Teknologi Laboratorium Medik (TLM) dengan tujuan untuk memperluas pengetahuan, pemikiran dan penelitian di bidang laboratorium kesehatan. Topik yang diangkat meliputi hematologi, kimia klinik, imunoserologi, imunohematologi, sitohitoteknologi, mikrobiologi, parasitologi, dan toksikologi klinik.
Articles 53 Documents
PENGARUH SUMBER DAYA MANUSIA (SDM) TERHADAP KUALITAS SEDIAAN BASIL TAHAN ASAM (BTA) DI FASILITAS KESEHATAN KABUPATEN CILACAP PADA TAHUN 2022 Anggih Priyanto; Ira Pangesti; Akhmad Mubarok
Journal of Indonesian Medical Laboratory and Science Vol 4 No 2: Oktober 2023
Publisher : Asosiasi Institusi Pendidikan Tinggi Teknologi Laboratorium Medik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53699/joimedlabs.v4i2.165

Abstract

Tuberculosis (TB) is a dangerous infectious disease that causes many deaths, and control needs to be carried out so that TB transmission and mortality rates can decrease. The COVID-19 pandemic has had an impact on TB elimination targets, so that targets have slowed, stopped or retreated. One of the efforts made to improve again is to carry out External Quality Control (PME) by the UPTD health laboratory of the Health Office to supervise that the quality of laboratory examinations in health facilities produces accurate and thorough examinations, therefore the Human Resources (HR) factor needs to be considered to obtain quality examination results. This study aims to determine the effect of human resources on the quality of BTA preparations in health facilities in Cilacap Regency in 2022. This study was conducted by analyzing the value of PME results on the quality of BTA preparations in 2022 with the results of questionnaire observation scores regarding human resources for 30 respondents in health facilities in Cilacap Regency who were randomly selected. Pearson correlation statistical test was used, resulting in a significant relationship between human resources and the quality of BTA preparations in health facilities in Cilacap Regency in 2022 with a value of 0.008 <0.05. The quality of specimens, size and thickness of the preparation have many discrepancies in the manufacture of BTA preparations in health facilities, training needs to be carried out routinely to control the quality of BTA preparations.
PERBANDINGAN JUMLAH LEUKOSIT PADA PENGGUNA ROKOK ELEKTRIK DAN ROKOK KONVENSIONAL Uray Dinda Saputri; Fadli Sukandiarsyah; Khairul Bariyah
Journal of Indonesian Medical Laboratory and Science Vol 4 No 2: Oktober 2023
Publisher : Asosiasi Institusi Pendidikan Tinggi Teknologi Laboratorium Medik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53699/joimedlabs.v4i2.166

Abstract

Smoking has become a habit that often occurs in everyday life for people in Indonesia. There are many alternative ways that can be done on tobacco cigarettes. This type of electric cigarette is one of the newest phenomena to replace tobacco cigarettes. The side effect of cigarette smoke is that we can see an inflammatory response through an increase in the number of leukocytes in the peripheral blood. This study aims to determine the comparison of the number of leukocytes in electric cigarette users and conventional cigarettes. This type of research is analytic observational with cross sectional research design. The sampling technique used purposive sampling with a total sample of 30 electric smokers and 30 conventional smokers. Research by conducting the Mann-Whitney test on a comparison of the number of leukocytes in users of electric cigarettes and conventional cigarettes with a significant value of 0.05 obtaining P = 0.717. There is no difference in the number of leukocytes in the use of electric cigarettes and conventional cigarettes. the conclusion is the conclusion of the results and discussion presented in the results and discussion chapter.
PENGARUH PENYIMPANAN REAGEN KERJA TERHADAP AKTIVITAS ENZIM ALANINE AMINOTRANSFERASE Rafika Saeba Delfiana; Tiara Dini Harlita; Agus Rudi Hartono
Journal of Indonesian Medical Laboratory and Science Vol 4 No 2: Oktober 2023
Publisher : Asosiasi Institusi Pendidikan Tinggi Teknologi Laboratorium Medik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53699/joimedlabs.v4i2.187

Abstract

The activity of the Alanine Aminotransferase (ALT) enzyme in working reagents stored at 2 – 8°C will affect results of laboratory tests. Influencing factors are temperature and storage time. The aim of research was to determine effect of storage treatment working reagents with aliquots and without aliquots for 0, 7, 14 and 21 days at temperature 4°C on ALT enzyme activity. Research used Quasi Experimental, with Randomized Group Design. Research variables, the storage treatment of the ALT working reagent and the level of ALT enzyme activity. Sample used was 2,400 mL normal ALT control serum. Examination method is enzymatic using spectrophotometer. Data analysis used univariate analysis to calculate the average enzyme levels examined 3 times and bivariate analysis to test effect of storage treatment with Independent Sample T-test. Based on the average aliquot treatment content, highest yield on day 0, namely (59.0 U/L) and lowest yield on day 21, namely (45.7 U/L). Treatment without aliquots highest yield on day 0, namely (54.6 U/L) and lowest yield on day 21, namely (51.8 U/L). Results of treatment effect test have a significant value, aliquots can be used for up to 3 weeks and without aliquots can be used for up to 4 weeks.