The journal publishes research manuscripts dealing with problems of modern technology (power and process engineering, structural and machine design, production engineering mechanism and materials, etc.). It considers activities such as design, construction, operation, environmental protection, etc. in the field of mechanical engineering and other related branches. In addition, the journal also publishes papers in advanced materials related with advanced electronic materials, advanced energy materials, advanced engineering materials, advanced functional materials, advanced materials interfaces, and advanced optical materials.
Articles 68 Documents
CFD SIMULATION FOR AIRSPEED AND TURBULENCE VALIDATION IN MAIN DUCTING OF OFFICE BUILDING Sabilly Handi Pradana; Deni Shidqi Khaerudini
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 4, No 1 (2022)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (493.185 KB) | DOI: 10.22441/ijimeam.v4i1.12050

Abstract

This paper focuses on the calculation of sizing ducting based on cooling load requirements the main ducting of office building following regulation airspeed requirements using American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) and Computational Fluid Dynamics (CFD) simulations. The purpose of this research is to validate the airspeed and turbulence that occurs in the main ducting between manual calculations and CFD simulations. From the calculation, the cooling load requirement is 58.22 kW, for the cooling process an air flowrate of 7117 L/s is needed which is designed to pass through the main ducting in rectangular shape. The main ducting size uses 1200 mm x 500 mm at a speed of 12.7 m/s according to ASHRAE. Autodesk Inventor software is used for ducting modeling and Autodesk CFD is used for airflow simulation. CFD simulations are performed by applying boundary conditions and input parameters. The results showed that the velocity of the ducting design was suitable at 12.7 m/s with laminar flow. The ducting geometry must be designed aerodynamically to reduce the pressure drop which can cause the speed to increase so that it is outside the required limits. Thus, the CFD simulation results have verified the validity of manual calculations.
STUDY ON PARAMETERS IN COUNTER CURRENT DOUBLE PIPE HEAT EXCHANGER APPLYING CIRCULAR TURBULATOR Sudiono Sudiono; Rita Sundari; Rini Anggraini
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 2 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (342.031 KB) | DOI: 10.22441/ijimeam.v3i2.11876

Abstract

Many industries dealing with manufacturing and HVAC (heating, ventilation, and air cooling) are rely heavily on thermodynamics principles with respect to heat and mass transfer. The objective of this study is to do optimization to yield optimum heat transfer rate and minimized pressure drop with regard to number of circular turbulator (CT) and water debit on Nusselt number (Nu) in counter current double pipe heat exchanger. This work has applied the classical rule of thermal science dealing with Nusselt number in relation to convection and conduction of heat transfer rate due to temperature effect. The result shows the highest Nu found to be 835.3 at 5 CT and water debit of 9 L/min. The addition of CT number gives effect on fluid current due to vortex generation. This study also investigates the effect of CT number on friction coefficient that the friction coefficient of a heat exchanger in the absence of CT is lower than that in the presence of CT. For any CT number, the friction coefficient is reduced with increasing water debit. The study has also found that the thermal performance ratio has achieved higher values for heat exchanger in the absence of CT.
CHARACTERIZATION OF IRON PRODUCTION FROM MILLS CALE BY CARBOTHERMIC REDUCTION Lukman Faris Nurdiyansah; Nono Darsono; Deni Shidqi Khaerudini
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 1 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (809.803 KB) | DOI: 10.22441/ijimeam.v3i1.11575

Abstract

Millscale is a large by product of metal factory. Many methods to recycled it to many applications. The aim of this research is recycled millscale to produce the iron by reduction method with graphite as reductant agent. The reduction process was deed by milled millscale and graphite powder with 4:1 weight ratio was by used High Energy Milling with 4, 6, 12 hours milling time variations. The powder then was characterized by X-Ray Diffraction (XRD), Vibrating Sample Magnetometer (VSM) and SEM-EDS test. The XRD test result is Fe3C as a main phase then carbon, magnetite, wustite and Iron as a minor phase. The percentage of iron composition is increase during milling times amount to 6; 10.9; 13 %. The remanence for the 4, 6, and 12 hours of milling time variation, is 2.89, 3.39, and 4.98 emu/g, for the coercivity (Hc) is 209.58, 188.47, and 223.65 Oe and the magnetic saturation number is 22.59, 30.7, 39.15 emu/g, from Hc value it is concluded that the powder has superparamagnetic behavior.  From SEM-EDS is knowed that the distribution of Fe is more uniform on the surface samples with the increase of milling time.
Message from Chief Editor Ignatius Agung Wibowo
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 4, No 1 (2022)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (9.43 KB)

Abstract

WATERMELON PEEL EXTRACT AS GREEN CORROSION INHIBITOR FOR ST-37 CARBON STEEL IN SEAWATER Sri Teguh Priharti; Umar Kalmar Nizar; Rita Sundari; Sri Benti Etika; Budhi Oktavia; Ananda Putra; Rini Anggraini
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 3 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (529.174 KB) | DOI: 10.22441/ijimeam.v3i3.13759

Abstract

Corrosion engineering has taken great interest in many industries that required high cost management to overcome the serious problems. This work has investigated the role of watermelon peel extract as green inhibitor to protect carbon steel in seawater. This investigation has studied the corrosion rate and inhibition efficiency applying weight loss method.  The laboratory result shows the optimum inhibition efficiency found to be 71.64% at 5% inhibitor concentration in 100 ml seawater at room temperature. The effects of temperature and immersion time on inhibition efficiency have also been examined.  This study has used Arrhenius equation based on activation energy to determine type of adsorption encountered with corrosion process. The result shows a chemical adsorption justified by its high adsorption heat and strengthened by FTIR and UV-Vis examinations. The phytochemical examination of watermelon peel extract gives positive response to flavonoid, alkaloid, and saponin. The finding is useful for many industries encountered with carbon steel corrosion in corrosive medium using green inhibitor.   
Message from Chief Editor Ignatius Agung Wibowo
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 1 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (8.162 KB)

Abstract

EVALUATION ENERGY SAVINGS AT MALUKU PROVINCE OFFICE BUILDING IN JAKARTA Tommy Martin Syauta; Deni Shidqi Khaerudini
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 4, No 1 (2022)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (281.251 KB) | DOI: 10.22441/ijimeam.v4i1.14491

Abstract

The electricity is very important to support activities in office building .The equipment like AC ( Air conditioning ) needs more electricity to be operated. The is almost 60%  is use to support this system (AC). This percentage describe that air condition system is an equipment that needs more electricity in the office and its become inefficiency in using electricity. To take overcome for this problem we need to efficiency in using energy. One of the method that now used to efficient that energy is called “ energy conversation” This method is using to saving the energy There is one thing that must be done in this activity which is “ energy audit “. Audit energy is one of method calculate IKE (  Intension Consumption  Energy) at on the building.The first preliminary audit shown that more energy, which 60% is use to operated the air conditioning (AC) system and 30% to operate lighting system. IKE for the lighting system is still below from maximum standard  which is 15 watt/m²The opportunity of saving energy on audit energy in AC system is done by cleaning up consist of : cleaning up filter, propeller corner fin of the evaporator, and the grill of in door unit.
EFFECT OF DISCHARGE VARIATION ON THE PERFORMANCE OF SINGLE BLADE ARCHIMEDES SCREW TURBINE: PREDICTION WITH COMPUTATIONAL FLUID DYNAMIC Gunawan Rudi Cahyono; Apip Amrullah; Pathur Razi Ansyah; N. Alexius Mikael; P.S.M. Reynaldi; Rusdi Rusdi
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 2 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (455.518 KB) | DOI: 10.22441/ijimeam.v3i2.12459

Abstract

Constructing a small-scale hydroelectric power station that can run efficiently at a head lower than 10 m is one possible method for reducing the impact of the electricity crisis in remote areas of Indonesia. The Archimedes Screw turbine is one type of turbine that is ideal for discharges below 10 m. In this study, the simulation results show that the value of Turbulences Kinetic Energy is directly proportional to the increase in flow rate but inversely proportional to the level of immersion. This type of turbine is unless well in Indonesia due to a lack of information regarding the application of low head power plants. The turbine model that is suitable for the low head is investigated in this study. Before being tested, the turbine is first designed theoretically and then numerically evaluated. With discharges of 1 l/s, 2 l/s, and 3 l/s and turbine immersion levels of 30%, 50%, and 70%, ANSYS CFD (Computational Fluid Dynamic) software was used to investigate flow rate and level of immersion in the turbine. According to the investigation findings, the discharge has a considerable impact on the turbine's movement; the higher the flow rate, the higher the power to the turbine, which produces a torque on the turbine. The simulation findings indicate that the value of Turbulence Kinetic Energy is proportional to the increase in flow rate but inversely proportional to the level of immersion.
ENERGY AND COST SAVING OF AIR CONDITIONING SYSTEM USING MAGNETIC BEARING CHILLER FOR HOTEL A IN JAKARTA Agus Marjianto; Hafthirman Hafthirman; Prihadi Setyo Darmanto
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 1 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (524.603 KB) | DOI: 10.22441/ijimeam.v3i1.11356

Abstract

The use of magnetic bearing chillers in hotel air conditioning systems is an opportunity for energy or cost savings. This study will compare the electrical energy consumption and cost analysis of the centralized air conditioning system using magnetic bearing chiller that uses variable flow to another air conditioning system such as the centralized air conditioning using constant flow chiller and the VRF split air conditioning system at Hotel A in Jakarta. The calculation of energy consumption for each air conditioning system is carried out for a year. Meanwhile, the cost analysis will be carried out using the life cycle cost method for 20 years. The air conditioning system which has the least energy consumption and has the lowest life cycle cost is the best air conditioning system for this hotel building. The maximum cooling load that occurs in Hotel A is 3,281 kW. From the results of energy calculations and cost analysis, a centralized air conditioning system with magnetic bearing chiller with variable flow is the best choice to Hotel A or similar building to Hotel A, with IKE (Intensitas Konsumsi Energi) value of 84 kWh/(m2.year), and a total cost of 78,873,678,478.00 IDR for a period of 20 years.
FAILURE ANALYSIS OF SCREW COMPRESSOR AND ITS MODIFICATIONS Aat Safaat; Alfian Noviyanto
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol 3, No 3 (2021)
Publisher : Universitas Mercu Buana, Prodi S2 Teknik Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (261.3 KB) | DOI: 10.22441/ijimeam.v3i3.12963

Abstract

Screw compressor is one of critical equipment at many industries. Therefore, its reliability and performance shall be maintained. One problem that often arises with screw compressors is the lubrication system. This study investigates the cause of the screw compressor failure and its modification to prevent failure in the future. The failure analysis of the screw compressor was successfully conducted using the fishbone analysis diagram and visual examination. The presence of water in the oil was found due to a change of oil color. The water content analysis showed that 6% of water was found in the oil in the third month. Indeed, the presence of water has a detrimental effect on the screw compressor part, showing that corrosion has occurred in the inner part of the screw ompressor element. We found the water source comes from the air due to high humidity. Therefore, modification in the air supply is needed to prevent water contamination in the oil. The air supply modification is done using dry air at the screw compressor outlet, flowing into the breather system. The modification results showed that the oil's water content decreased significantly from 6% to 0.0035%. In addition, the vibration that occurs decreases from 80 dB to 58 dB. This shows the effectiveness of the modification process to extend the life of the tool and maintain the plant's operational continuity.