cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir, Jurnal ilmiah diterbitkan oleh Pusat Rekayasa Perangkat Nuklir - BATAN Alamat Rekaksi: Pusat Rekayasa Perangkat Nuklir (PRPN) - BATAN
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 13, No 1 (2016): Juni 2016" : 6 Documents clear
PEMBUATAN KOTAK PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR Wiranto Budi Santoso; Abdul Jalil
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2499.437 KB)

Abstract

ABSTRAKPEMBUATAN KOTAK PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR. Telah dilakukan pembuatan kotak penangkap citra sinar-X berbasis layar pendar. Pada perangkat sinar-X berbasis layar pendar, suatu citra dihasilkan dengan menangkap citra sinar-X dari obyek yang terbentuk di layar pendar. Kotak penangkap citra digunakan untuk memastikan bahwa citra obyek yang terbentuk pada layar pendar dapat ditangkap oleh kamera di dalam kotak. Dengan demikian kotak harus tidak dapat ditembus cahaya dari luar. Cahaya di dalam kotak hanya berasal dari citra obyek yang terbentuk pada bagian layar pendar. Ukuran kotak harus kompak tetapi cukup besar untuk dapat menampung layar pendar, kaca timbal, kamera digital, dan catu daya. Posisi kamera di dalam kamera juga dapat diatur sehingga fokus lensa kamera dapat menangkap citra pada layar pendar. Kotak untuk menangkap citra sinar-X berbasis layar pendar terbangun dibuat menggunakan bahan aluminium f 19 untuk bagian samping dan belakang. Bagian dalam dari panel aluminium dicat hitam untuk menghindari pantulan cahaya. Bagian depan kotak dibuat dari  bahan fiberglass yang diberi bingkai dari stainless steel (SS). Dimensi kotak adalah 284x364x820 mm. Hasil pengujian menunjukan bahwa kamera dalam kotak dapat menangkap citra sinar-X dari obyek yang terbentuk pada layar pendar. Citra yang dihasilkan ditentukan oleh tegangan operasional (KV) perangkat sinar-X. Semakin besar KV, semakin kontras citra yang dihasilkan. Resolusi citra tergantung pada resolusi kamera yang digunakan.Kata kunci: layar pendar, perangkat sinar-X, citra ABSTRACTCONSTRUCTION OF FLOURESCENSE SCREEN BASED X-RAY IMAGE CAPTURING BOX. A box for capturing X-ray image based on flourescense screen has been developed. In flourescense screen based X-ray machine, an image is produced by capturing X-ray image of object formed in flourescense screen. The box is used to make sure that the object image formed in the flourencense screen can be captured by camera inside the box. Therefore the box should not be able penetrated by lights. The light inside the box come only from the image of object formed in flourencense screen. Its size should be compact and  large enough to accommodate flourescense screen, lead glass, digital camera, and its power supply inside. Furthermore, the camera’s position inside the box can be adjusted so that the lens focus of the camera can capture the formed image in flourescense screen. The built box for capturing X-ray image based on flourescense screen is constructed using aluminium f 19 for the surrounding and back sides. The inside aluminium panels are painted in black color to avoid light reflection. The front side of the box is constructed using fiberglass framed by stainless steel (SS). The box dimension is 284x364x820 mm. The test result shows that  the camera in the box can capture X-ray image of the object formed in the flourescense screen. The resulting images are determined by X-machine’s operating voltage (kV). The images are showed more contrast in higher operating voltage. The image resolution depends on the camera resolution.Keywords: flourescense screen, X-ray machine, image
DESAIN RINCI KONTAINER SUMBER RADIASI Ir-192 DAN LANDASANNYA PADA PERANGKAT BRAKITERAPI HIGH DOSE RATE (HDR) Rahmat Rahmat; Tri Harjanto; Ari Satmoko
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1530.461 KB)

Abstract

Abstrak            DESAIN RINCI KONTAINER SUMBER RADIASI Ir-192 DAN LANDASANNYA PADA PERANGKAT BRAKITERAPI HIGH DOSE RATE (HDR). PRFN BATAN mengembangkan perangkat brakiterapi dosis tinggi dengan memperbaiki prototip awal perangkat brakiterapi dosis sedang. Sumber radiasi yang akan digunakan adalah Ir-192 dengan aktifitas 15 Ci. Secara umum, perangkat brakiterapi terdiri dari tiga modul yaitu modul penggerak sumber, modul kontainer sumber dan modul distributor channel. Berbagai perbaikan dilakukan yang di antaranya adalah merubah desain modul kontainer sumber. Bahan timbal sebagai perisai radiasi diganti dengan tungsten. Kegiatan desain rinci diawali dengan menggambar komponen-komponen utama dari modul kontainer sumber yaitu tube kontainer, kontainer tungsten, silinder timbal, penutup timbal, dan dudukan kontainer. Setelah semua komponen tergambar, tahap berikutnya adalah mendesain proses perakitan untuk membentuk modul kontainer sumber. Baik pemodelan komponen maupun proses perakitan dikerjakan menggunakan piranti lunak SolidWORK untuk mengurangi kemungkinan kesalahan desain. Dengan desain baru ini, berat kontainer perisai radiasi dapat ditekan hingga menjadi sekitar 30 kg yang semula 80 kg. Landasan atau base plate juga didesain untuk memposisikan modul kontainer sumber terhadap modul-modul lainnya.Kata kunci : Brakiterapi , desain rinci, kontainer sumber, tungsten, landasan ABSTRACT                                                                     A DETAILED DESIGN OF Ir-192 RADIATION SOURCE CONTAINER AND ITS BASE FOR HIGH DOSE RATE (HDR) BRACHYTHERAPY DEVICE. PRFN BATAN develops high-dose rate brachytherapy equipment to improve the preliminary medium dose rate prototype. The radiation source to be used is Iridium-192 with activity of 15 Ci. In general, brachytherapy equipment consists of three modules, namely driving source module, source container module and distributor channel module. Various improvements are developed which of them is modifying the design of the container resource module. Lead as radiation shielding material is replaced with tungsten. Detailed design activity begins by drawing the main components of the module container sources that are container tube, tungsten container, lead cylinder, lead covers, and container holders. After all the components envisaged, the next step is to design an assembly process into a source container module. Both components model and the assembly process are developed using the SolidWORK software to reduce the possibility of design errors. With this new design, the weight of radiation shielding container in tungsten can be reduced to approximately 30 kg instead of 80 kg by using lead material. A base plate is also designed to position the source container modul among other modules.Keywords: brachytherapy, detailed design, source containers, tungstene, baseplate
MENENTUKAN POSISI TITIK FOKUS PESAWAT SINAR-X PADA HASIL TANGKAP CITRA DENGAN KOTAK REKONSTRUKSI Ahmad Rifai; Wahyuni Imran
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2112.919 KB)

Abstract

ABSTRAKMenentukan posisi titik fokus pesawat sinar-x pada hasil tangkap citra dengan  kotak rekonstruksi.Telah dikembangkan modul perangkat lunak kalibrasi yang merupakan bagian dari perangkat lunak Treatment Planning System (TPS) Brakiterapi. Modul ini digunakan untuk menentukan posisi titik fokus pesawat sinar–X dari masukan berupa pasangan  citra AP dan citra LAT. Citra ini diperoleh dengan bantuan kotak rekonstruksi LAZ11-03 yang disinari secara semi-orthogonal, yaitu dari arah AP dan LAT. Dengan menggunakan informasi pada citra tersebut akan dihitung posisi titik fokus pesawat sinar-X berdasarkan data koordinat marker-acuan dan proyeksinya. Perhitungan ini dilakukan dengan menggunakan teori geometri 3D sederhana  yaitu penyelesaian persamaan titik potong sebuah garis linier pada sebuah bidang datar.Kata kunci:Treatment, Planning, System, Brakiterapi, Rekonstruksi ABSTRACTdetermining x-ray focal point based on image projection using reconstruction box. An application software as part of brachytherapy’s Treatment Planning System (TPS) has been developed. The application will be used for determining focal point of x-ray machine based on both AP and LAT images. The images are obtained with the help of reconstruction box LAZ11-03 using semi-orthogonal projection, from direction AP and LAT respectively. Based on these images, the focal point of the x-ray machine will be determined using a given reference marker and its projection. The calculation is done with simple 3D geometry theory to solve the equation of intersection point between a straight line and a plane.Keywords:Treatment, Planning, System, Brachytherapy, Reconstruction
PERANCANGAN AKUISISI DATA DENGAN KOMUNIKASI BLUETOOTH PADA ANALISA UNSUR DENGAN TEKNIK XRF UNTUK INDUSTRI KERTAS Ikhsan Shobari; Beny Syawaludin; Wahyuni Imran; Rony Djokorayono
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3236.819 KB)

Abstract

ABSTRAKPERANCANGAN AKUISISI DATA DENGAN KOMUNIKASI BLUETOOTH PADA ANALISA UNSUR DENGAN TEKNIK XRF UNTUK INDUSTRI KERTAS. Pengukuran gramatur, kelembaban dan  kadar abu secara on-line di industri kertas dengan teknik XRF dapat menghemat waktu dan mengoptimalkan pemakaian aditif. Komputer proses berfungsi sebagai data logger dan antar muka operator dengan mesin. Data hasil pembacaan sensor dikirim dari detektor dengan standar arus 4 – 20 mA. Sinyal dikonversi menjadi nilai digital, dan  dilakukan perhitungan di modul dedicated computer. Data  selanjutnya dikirim ke komputer proses dengan komunikasi serial secara nirkabel dengan media bluetooth. Pengujian berhasil dilakukan di dalam ruangan dengan jarak paling jauh 8 meter tanpa terputus, dan kehilangan data.Kata kunci: bluetooth, data_logger, XRF_industri  ABSTRACT DATA ACQUISITION DESIGN FOR ELEMENTS ANALYSIS WITH XRF TECHNIQUE FOR INDUSTRIAL PAPER USING BLUETOOTH COMMUNICATION. On-line measurements of paper grammage, of moisture content of ash using XRF techniques is save many time and optimize the use of additives. Process computer serves as a data logger and as the interface between machine and operator. Data from the sensor are sent from the detector in standard current 4-20 mA. The signal is converted into a digital value, and calculation is performed on the dedicated computer module. The data is then sent to the process computer in wireless serial communication by using bluetooth media. Test as succesfully performed in Results of design successfully tested in indoors with a maximum distance of 8 meters without interruption and no data loss.Keywords: bluetooth, data_logger, XRF_industry
DESAIN BASKET SENTRIFUGAL UNTUK PROSES FILTRASI SLURRY TORIUM HIDROKSIDA Abdul Jami; Hafni Lissa Nuri
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1012.795 KB)

Abstract

ABSTRAKDESAIN BASKET SENTRIFUGAL UNTUK PROSES FILTRASI SLURRY TORIUM HIDROKSIDA. Pilot plant ThO2 dari tailing pengolahan monasit kapasitas 100 kg/hari merupakan proses untuk mengambil torium dalam bentuk oksida ThO2yang terdiri dari 3 tahap proses, yaitu proses preparasi, proses ekstraksi dan proses dekomposisi thermal. Salah satu alat yang diperlukan untuk mendukung ketiga proses diatas adalah basket sentrifugal yang digunakan untuk proses filtrasi torium hidroksida.Telah dilakukan perhitungan teknis dalam rangka desain basket sentrifugal. Bentuk basket sentrifugal adalah silinder tegak dengan volume desain basket 0,23 m3. Adapun dimensi basket adalah diameter 1,2 m, tinggi 0,20 m. Beban maksimum 1800 kg, material konstruksi SS-316L, waktu filtrasi 96 detik dan total daya yang diperlukan 11 kW.Kata kunci:  Basket, Filtrasi, Sentrifugal, Torium Hidroksida ABSTRACTDESIGN OF BASKET CENTRIFUGE FOR FILTRATION PROCESS OF SLURRY OF THORIUM HYDROXIDE. Pilot plant of ThO2 from tailing monazite processing with capacity of 100 kg/day is a process for recovering thorium ThO2that consists of 3 process stages: preparation process, extraction process and thermal decomposition process. One of equipment’s required for support in third process is basket centrifuge for filtration process of thorium hydroxide. In order to design the basket centrifuge engineering calculations are performed. The type of the basket centrifuge is vertical drum with volume basket is 0,23 m3. The dimension is 1,2 m in diameter, 0,20 m in height. Maximum load is 1800 kg, construction material is SS-316L, time of filtration is 96 second and total power required is 11 kW.Key words:  Basket, Filtration, Centrifuge, Thorium Hydroxide 
DESAIN AWAL PILOT PLANT PENGOLAHAN TAILING MONASIT MENJADI ThO2 KAPASITAS 100 KG/HARI Hafni Lissa Nuri
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 1 (2016): Juni 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1122.55 KB)

Abstract

ABSTRAK            DESAIN AWAL PILOT PLANT PENGOLAHAN TAILING MONASIT MENJADI ThO2  KAPASITAS  100 KG/HARI. Telah dilakukan kegiatan desain pilot plant pengolahan tailing monasit menjadi ThO2 yang bertujuan untuk membuat dokumen desain pilot plant dengan ruang lingkup desain proses. Dokumen tersebut berisikan data properties, blok diagram proses, perhitungan peralatan proses, preliminary process flow diagram (PFD), preliminary P&ID dan  plot plan. Pilot plant merupakan aplikasi data hasil laboratorium yang akan diimplementasikan ke skala industri. Tailing monasit (RE,U,Th)OH merupakan limbah pengolahan monasit (RE,U,Th)PO4 yang telah diambil sebagian besar unsur tanah jarangnya (RE). Torium (Th) sebagai bahan radioaktif, digunakan sebagai bahan bakar nuklir pengganti uranium, dimana saat ini cadangan uranium semakin berkurang sementara cadangan torium 3-4 kali cadangan uranium dan belum diolah secara komersial. Keberadaan monasit di Indonesia cukup melimpah sekitar 1.5 milyard ton, saat ini monasit banyak dihasilkan dari pemisahan pasir timah oleh PT. Timah di Bangka Belitung. Kandungan torium di dalam pasir monasit  sekitar 3-6 % dan sangat layak untuk diolah. Berdasarkan perhitungan neraca massa maka dengan  mengolah 100 kg/hari tailing  monasit   akan   diperoleh produk ThO2 sebanyak 2,3 kg/hari.Kata kunci : pilot plant,  tailing monasit, torium oksida ABSTRACT             A PRELIMINARY DESIGN OF PILOT PLANT FOR PROCESSING MONAZITE TAILING TO ThO2 CAPACITY 100 KG / DAY. Preliminary design activities have been conducted for pilot plant processing of monazite tailings to ThO2 which aims to create a pilot plant design document with the scope of the design process. The document contains a block diagram of the process,  data properties, calculation of the main process equipment, preliminary process flow diagram (PFD), preliminary  P & ID and plot plan. The pilot plant is application data of laboratory results to be implemented on an industrial scale. Monazite tailings (RE, U, Th) OH are residu from the processing of monazite (RE, U, Th) PO4 that has been taken its PO4 and most RE. Thorium (Th) as radioactive  materials to be used as nuclear fuel instead of uranium  which is now diminishing reserves, while the reserves of thorium 3-4 times reserves of uranium and have not been processed commercially. The existence of monazite in Indonesia is quite abundant around 1.5 billion tonnes, is currently a lot of monazite sand resulting from the separation of tin by PT. Tin in Bangka Belitung. The content of thorium in monazite sand is about 3-6% and very worthy to be processed.  Based on the mass balance calculation process 100 kg / day of monazite tailings will be obtained ThO2 product as much as 2.3 kg / day.Keywords: pilot plant, monazite tailings, thorium oxide

Page 1 of 1 | Total Record : 6