cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Ilmiah Giga
ISSN : 14108682     EISSN : 26219239     DOI : -
Core Subject : Education,
GIGA Scientific Journals is a scientific publication from research and literature study which are conducted by undergraduate, graduate, doctoral student, researchers and lecturers to be published widely and can be utilized as widely as possible for the advancement of science and technology at domestic and aroud the world.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue " Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016" : 6 Documents clear
Analisis Radiasi Hambur di Luar Ruangan Klinik Radiologi Medical Check Up (MCU) Anita, Febria; Arizal, Muh. Zakky; Panular, Dwi Bondan; Santoso, Budi
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Telah dilakukan penelitian tentang Analsisis Radiasi Hambur di Luar Ruangan Klinik Radiologi Medical Check Up (MCU). Penelitian ini bertujuan untuk mengetahui dosis radiasi hambur yang diterima titik perisai dan Pola sebaran radiasi hambur di belakang titik perisai. Penelitian ini menggunakan surveymeter sebagai alat ukur radiasi. Proses pengambilan data dilakukan dengan cara peneliti berdiri dibelakang dinding setiap dilakukan pemeriksaan dengan faktor eksposi yang sudah ditentukan yaitu 50, 55, dan 60 kV dengan waktu 16 mAs. Pengambilan data dilakukan dengan beberapa kali agar datamenjadi lebih akurat. Hasil dari penelitian ini adalah didapatkan laju dosis radiasi sebesar 0,477, 0,76, dan 0,897mSv/tahun masih jauh dari nilai batas dosis untuk pekerja radiasi 20 mSv dan masyarakat umum 1 mSv. Pola sebaran radiasi hambur kenaikan yang signifikan ditujukan oleh dinding penahan yang merupakan shielding F yang terletak di didalam ruangan untuk tempat berlindungnya petugas radiasi ketika melakukan pemeriksaan. Kata kunci: Shielding, Surveymeter, Dosis Radiasi, Faktor Eksposi.
Studi dan Evaluasi Kayu sebagai Bahan Dasar Quadratic Residue Diffuser Akustik Wicaksono, Aditya Imam; Repi, V. Vekky Ronald; Santoso, Hari Hadi
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Penelitian ini membahas tentang pengujian diffuser dengan menggunakan kayu-kayu yang berbeda (kayu tripleks meranti, kayu jati, dan kayu kamper). Tujuan pengujian ini adalah untuk memudahkan insinyur akustik memilih kayu yang akan digunakan sebagai diffuser dalam perancangan tata suara auditorium. Pengujian dilakukan dengan metode boundary plane measurement yang merujuk pada AES-4id-2001. Hasil pengujian diperoleh grafik respon polar dan koefisien difusi dengan frekuensi 800 Hz, 1000 Hz, dan 1250 Hz. Berdasarkan pengujian tersebut, kayu kamper merupakan kayu yang terbaik untuk dijadikan diffuser. Kata Kunci:  Boundary Plane Measurement, Grafik Respon Polar, Kayu, Koefisien Difusi, Quadratic Residue Diffuser.
Perancangan Sistem Kontrol On/Off Multivariabel Level dan Temperatur Berbasis Microcontroller Yunus, Ridwan; Repi, V. Vekky Ronald; Hidayanti, Fitria
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Proses yang ada di industri umumnya mempunyai karakteristik yang non linier, multivariabel dan kompleks. Pada penelitian ini telah dilakukan pengendalian multivariabel yaitu level dan temperatur dengan aplikasi sistem miniplant Boiler dimana fungsinya adalah mengubah air menjadi uap dengan menggunakan metode pengendalian kontrol on/off menggunakan mikrokontroller. Dari hasil simulasi diperoleh rise time untuk pengendalian level adalah 733 detik dan untuk pengendalian temperatur 1013 detik. Sedangkan hasil dari pengujian miniplant diperoleh rise time untuk pengendalian level adalah 570 detik dan untuk pengendalian temperature adalah 1240 detik. Dari hasil penelitian dapat disimpulkan bahwa sistem pengendalian pada miniplant tidak dapat di aplikasikan pada sistem dinamis. Kata kunci: Boiler, Multivariabel, Pengendalian level, Pengendalian temperatur, Mikrokontroller.
Perancangan Sistem Monitoring Meter untuk Aplikasi Meter Orifice Menggunakan Perangkat Lunak PI ProcessBook Amril, Amril; Tunggadewi, Desty Anggita; Santoso, Hari Hadi
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Telah dibuat sistem monitoring meter untuk aplikasi meter orifice dengan menggunakan perangkat lunak Plant Information ProcessBook. Meter orifice bekerja dengan mengukur beda tekanan antara tekanan tinggi dan tekanan rendah yang di akibatkan penyempitan aliran di orifice plate dan kemudian di konversi menjadi laju alir. Laju alir dan parameter proses ditampilkan di sistem monitoring meter dengan menggunakan perangkat lunak Plant Information ProcessBook. Performa meter orifice di ukur dengan menganalisa ketidakpastian sistem meter dan di kalibrasi dengan druck pressure calibrator. Kata kunci: Orifice meter, ProcessBook, Monitoring, Tekanan, Laju alir
Prototipe Sensor Rasa Portable Berbasis Campuran Lipid Dioctyl Phosphate Dan Trioctyl Methyl Ammonium Chloride Dengan Perbandingan Massa 9:1 Amalinda, Finta
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Telah dibuat prototipe sensor rasa portable berupa ion meter dua kanal dan satu membran selektif ion. Ion meter dua kanal dibuat sebagai awal pengembangan sistem sensor rasa atau electronic tongue (e-tongue) yang harusnya berupa ion meter multi-kanal. Ion meter dibuat dengan menggunakan IC op-amp LF412 sebagai amplifier dan mikrokontroller Atmega8535. Sementara itu, membran selektif ion dibuat dengan variasi campuran lipid dioctyl phosphate (DOP) dan triocthyl methyl ammonium chloride (TOMA). Dengan perbandingan massa masing-masing 9:1. Pada sensor rasa ini , lipid menetukan selektifitas membran terhadap ion-ion tertentu. Luaran dari sensor rasa (ion meter yang dilengkapi dengan membran selektif ion) berupa potensial listrik yang selanjutnya dibandingkan dengan potensial elektroda referensi. Selanjutnya, prototipe sensor rasa portable  tersebut diuji kemampuan sensingnya terhadap lima macam larutan: glukosa, KCl, kina, HCl dan MSG. Kelima larutan tersebut mewakili lima macam rasa dasar, yakni rasa manis diwakili oleh glukosa, rasa asin diwakili oleh KCl, rasa pahit diwakili oleh kina, rasa asam diwakili oleh HCl, dan umami diwakili oleh MSG. Setiap larutan sampel dibuat dengan pelarut 1 mM KCl dan divariasi menjadi tujuh macam konsentrasi. Sebagai hasilnya, sensor rasa dengan membran lipid campuran 9:1 menujukkan kecenderungan respon terhadap kation sampel, sehingga menghasilkan besar potensial yang mengalami peningkatan untuk setiap kenaikan konsentrasi.  Kata Kunci: sensor rasa, ion meter, membran selektif ion, lipid, diocthyl phosphate, triocthyl methyl ammonium chloride
Verifikasi Distribusi Dosis Tps Dan Pesawat Linac Menggunakan Phantom Octavius 4d Dengan Teknik IMRT Protokol Kanker Lidah Anita, Febria; Wali, Tomas
Jurnal Ilmiah Giga Vol 19, No 1 (2016): Volume 19, Edisi 1, Juni 2016
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (25.738 KB)

Abstract

ABSTRAK. Tindakan terapi bertujuan untuk hasil yang optimal berupa kematian jaringan kangker sebanyak mungkin dan kerusakan minimal pada jaringan sehat sehingga dilakukan upaya untuk mengoptimalkan hasil pengobatan radiasi.  IMRT merupakan salah satu teknik radioterapi menggunakan pesawat LINEC dengan banyak lapangan penyinaran yang menggunakan intensitas radiasi yang berbeda – beda untuk mendapatkan dosis maksimal pada organ target tumor dan dosis seminimal mungkin pada organ sehat. Verifikasi dilakukan dengan menggunakan Octavius 4D. Dari penelitian yang telah dilakukan pada 2 pasien dengan protokol kanker lidah, dimana 2 pasien dilakukan verifikasi pada setiap lapangan dan gabungan semua lapangan, Didapatkan kesesuaian piksel bagus untuk semua pasien dengan kriteria γ ≤ 1 pada 5 % DD, dan 3 mm DTA. Hasil verifikasi untuk semua lapangan penyinaran didapat kesesuaian piksel yaitu 99,7% untuk pasien 1 dan 2 Kesesuaian piksel untuk dan pasien 2 hasil verifikasi untuk semua lapangan penyinaran didapat kesesuaian piksel yaitu 98,4 %. Kesesuaian piksel untuk verivikasi setiap lapangan penyinaran pada pasien 1 : 96,8 %, 86,0 %, 96,2 %, 97,8 %, 98,5 %, 96,3 %, 93,9 %, pasien 2 : 97,8 %, 94,2 %, 95,1 %, 97,9 %, 98,5 %, 88,2 %, 96,2 %. Perbedaan pengukuran disebabkan antara lain karena pergerakan MLC secara dinamis, tegangan arus yang tidak stabil, temperatur ruangan yang selalu berubah - ubah dan daerah dosis rendah. Kata kunci : IMRT, Verifikasi Octavius 4D, Kanker Lidah

Page 1 of 1 | Total Record : 6


Filter by Year

2016 2016