Jurnal Imejing Diagnostik
ISSN : 2356301X     EISSN : 26217457     DOI : -
Core Subject : Health,
Jurnal Imejing Diagnostik (JImeD) memuat tulisan ilmiah dalam bidang radiologi berupa hasil penelitian dan non penelitian (konseptual). Jurnal Imejing Diagnostik (JImeD) terbit 2 kali dalam satu tahun yaitu pada bulan Januari dan Juli oleh Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik Kesehatan Kemenkes Semarang. Jurnal Imejing Diagnostik (JImeD) memuat artikel ilmiah dalam bidang radiologi, meliputi : radiografi konvensional, digital radiografi, CT scan, MRI, kedokteran nuklir, radioterapi dan ilmu lainnya yang berkaitan dengan radiologi.
Arjuna Subject : -
Articles 9 Documents
Search results for , issue "Vol 9, No 2: JULY 2023" : 9 Documents clear
Efektifitas Variasi Window Width Terhadap Informasi Anatomi CT Scan Sinus Paranasal Citra Jaringan Lunak Pada Kasus Sinusitis Tezar Ridho Ramadhani; Siti Masrochah; Ary Kurniawati
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10330

Abstract

Background: Selection window width (WW) and window level (WL) must be precise to produce an optimal overview of anatomical information on CT scan paranasal sinuses soft tissue window in case of sinusitis. WW affects controlling contrast resolution. A wide window width will appear the less contrast of image. The aim of the study is to know the difference in anatomical information with variation WW and to know the most optimal WW value for CT scan paranasal sinuses soft tissue window in case of sinusitis.Methods: The research design is a quantitative experimental study, using WW variations (90, 120, 200, 350, 400). Anatomical assessment of osteomeatal unit, agger nasi cell, ethmoid roof, onodi cells, sphenoid sinus, optic nerve, middle turbinate, uncinate process, haller cells, And ethmoidal bulla. The friedman test is used to know a significant difference and the highest value of mean rank to know the most optimal WW value.Results: There is difference in information on each anatomical object with a significance value of 0.05 and there is difference in the total information on anatomical object with a significance value of 0.000 0.05. WW 120 is most optimal to display osteomeatal unit, agger nasi cell, ethmoid roof, onodi cells, middle turbinate, uncinate process, and ethmoidal bulla. WW 90 is most optimal to display sinus sphenoidalis, optic nerve, and haller cells.Conclusions: WW 120 is most optimal to display total anatomical information on CT scan paranasal sinuses soft tissue window in case of sinusitis.
Rancang Bangun Alat Ukur Jarak dengan Sensor Ultrasonik untuk Pesawat Sinar-X Mobile Muhammad Erfansyah; Budi Santoso; Puji Hartoyo
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10388

Abstract

Background: Many mobile X-ray aircraft currently do not have meters to measure the distance from the x-ray source to the patient, this makes it very difficult for a radiographer to adjust the position and distance correctly. Currently, there is still a need to develop more efficient and accurate distance measuring tools to support Mobile X-ray Aircraft maintenance.Methods: This research is experimental, making a distance measuring instrument using an ultrasonic sensor with the help of a microcontroller.Results: The device is applied for measuring the distance horizontally and vertically from 90 cm up to 130 cm. Step wisely from 90 cm to 130 cm at incrementally 10 cm. This device will be installed in the tube x-ray mobile device. Comparison is made for the distance in the vertical position of timed by the device to the measured distance using standard technique deviations more less then 0.044 % and in the horizontal 0.036.Conclusions: This concludes that the results obtained sufficiently by the device are accurate and can be recommended for x-ray mobile device accessory.
PROSEDUR PEMERIKSAAN MRI KNEE JOINT DENGAN KASUS CEDERA ANTERIOR CRUCIATE LIGAMENT (ACL) DI INSTALASI RADIOLOGI RS MARDI RAHAYU KUDUS Atika Dyah Kiranawati; Sugiyanto Sugiyanto; Agung Nugroho Setiawan
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10331

Abstract

Background: MRI examination of knee joints with Anterior Cruciate Ligament (ACL) injuries at the Radiology Installation of Mardi Rahayu Kudus Hospital using spin echo sequences, including PD_TSE, PD_TSE_fatsat, T1_SE, T2_TSE, and T2_TSE_fatsat, with the addition of STIR, and using DOT engine technology. This study aims to determine the procedures for examining knee joint MRI with cases of ACL injury, as well as the role of the DOT machine in the examination.Methods: This type of research is a qualitative research with a case study approach. The research subject was an MRI examination of the knee joint with ACL injury cases. Data collection is done by using the method of observation, study, and documentation. Data analysis includes data transcription, data reduction, data presentation, as well as discussing and drawing conclusions.Results: The results showed that the STIR sequence was used as a fat comparison. The resulting ACL image is an isointense image. The use of DOT engine technology helps to standardize inspections. The advantages are ease of making cuts, time efficiency, and uniformity of inspection techniques, and not finding operational weaknesses.Conclusions: The conclusion of this study is MRI of the knee joint using spin echo and STIR sequences, with DOT engine method. STIR could be used in certain indications. 
Peranan Magnetic Resonance Imaging (MRI) Lumbal dalam Penegakan Diagnosis Kasus Low Back Pain: Studi Kasus di Instalasi Radiologi Rumah Sakit Satya Negara Jakarta Utara Wahyu Setiyoningsih; Nursama Heru Apriantoro
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.9990

Abstract

Background: Magnetic resonance imaging (MRI) is considered the best imaging for chronic low back pain because of high tissue contrast and no effect of ionizing radiation. The purpose of this study was to determine the management of Lumbar MRI examination with Low Back Pain Cases.Methods: The research used was a qualitative descriptive research method by collecting data by direct observation which was conducted in December 2022 at Satya Negara Hospital, North Jakarta. The research was conducted using direct observation methods, documentation and decision studies. The sample used was 1 patient.Results: The image results are strengthened by the expertise of a radiologist. The results of the study were obtained from the beginning of the patient's process of coming to radiology to perform a Lumbar MRI examination in the administration section until the examination was completed. Using a GE 1.5 T MRI machine and a whole spine coil. The sequences used are 3-plane location, calibration scan lumbar, Coronal T2, Sagittal T2, Sagittal T1, Sagittal T2 + FATSAT, Axial T2, Sagittal Myelography, Coronal Myelography.Conclusions:  This study shows that Lumbar MRI image results and the doctor's expertise show that there is grade I spondylolithesis and L4-L5 spondyloarthrosis with disc protrusion. It’s mean that MRI can provide information for making a diagnosis.
MRI Otak Demensia: Protokol RSUP Dr. Sardjito Yogyakarta Dedi Hardianto; Fatimah Fatimah; Marichatul Jannah
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10405

Abstract

Background: The procedure for examining brain magnetic resonance imaging (MRI) in clinical dementia at the Radiology Installation of RSUP dr. Sardjito Yogyakarta used T2W, 3D FLAIR, 3D FFE ADNI, diffusion weighted imaging (DWI) and susceptibility weighted imaging (SWI) sequences.  The selection of this sequence was in accordance with the existing references, but was added with the SWI sequence. This study aims to determine the MRI brain examination in clinical dementia and to find out the reason for the addition of the SWI sequence.Methods: This type of research is a qualitative research with a case study approach. Data was collected by observation, in-depth interviews and documentation. Data analysis was carried out with the stages of data transcription, data reduction, data presentation and carried out discussions and drawing conclusions.Results: The results of the study stated that the measurement of brain volume was carried out by entering the raw data of the T1 FFE ADNI sequence image into the freesurfer software which was useful for assessing Alzheimer's dementia.Conclusions: The diagnosis is made by looking for bleeding and microbleeding using the SWI sequence in assessing vascular dementia. SWI sequences are useful in differentiating between calcification and microbleeding causing vascular dementia.
Pengaruh Penggunaan T2 Blade terhadap Kualitas Citra MRI Cervical Potongan Sagital pada Pasien Non-Cooperative Sriyatun Sriyatun; Eny Supriyaningsih; Yasinta Oktavianti
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10051

Abstract

Background: Using T2 BLADE in Cervical MRI examination can improve image quality because it can reduce artifacts especially with Non-Cooperative patients. The purpose of this study was to analyze the effect of T2 BLADE use on sagittal cut image quality in Non-Cooperative patients. The benefit of using T2 BLADE is that it provides insight to the reader and as an alternative in selecting the right sequence on Cervical MRI examination with Non-Cooperative patients so as to get an optimal and informative picture.Methods: The research design carried out was qualitative descriptive analytic with an observation and experimental approach which was carried out from May to June 2023 at Fatmawati Hospital using a Siemens Magnetom Altea 1.5T MRI aircraft. The population of this study was samples that performed Cervical MRI examination with a total of 6 samples. The data in this study is primary data collected by observation, experiments and questionnaires. Data processing and analysis was carried out by giving questionnaires to radiologst and radiographer who made subjective assessments and processed with simple calculations using Ms. Excel to find  the Mean.Results: The results of this study are, the image quality of Cervical MRI examination in Non-Cooperative patients  is more optimal using T2 BLADE sequences, the resulting images have quite informative results when compared to T2 TSE sequences. This study can be an option when conducting Cervical MRI examination  on Non-Cooperative patients  based on questionnaires, simple calculations and author analysis, so that patients get a diagnosis accurately and quickly.Conclusions: It can be concluded that the image quality of Cervical MRI examination in Non-Cooperative patients is  more optimal using T2 BLADE sequences, the resulting image has quite informative results. This study can be an option when conducting Cervical MRI examination  on Non-Cooperative patients  based on questionnaires, simple calculations and author analysis, so that patients get a diagnosis accurately and quickly.
Studi Kasus Pemeriksaan MSCT Urografi Multiphase dengan Klinis Tumor Ginjal Ratna Tri Rahayu; Nanang Sulaksono; Andrey Nino Kurniawan
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10402

Abstract

Background: The procedure for examining multi-slice computed tomography (MSCT) multiphase urography with clinical kidney tumors in the Radiology Installation of the Banyumas General Hospital differs from the literature in the use of scans in the corticomedullary phase and the post-contrast scanning phase. This study aims to determine the procedure for MSCT Urography Multiphase examination with clinical kidney tumors, to find out the reasons for using a scan of the corticomedullary phase area from the diaphragm to the pubic symphysis and to find out the reasons for using four phases of post-contrast scanning.Methods: This type of research is qualitative research with a case study approach. Data was collected at the radiology installation at the Banyumas Hospital from January to May 2023, the study respondents consisted of three radiographers, one radiologist, one sending doctor and one radiology nurse. Methods of data collection by observation, in-depth interviews, documentation. Data analysis was carried out through the stages of data collection, data reduction, data presentation and drawing conclusions.Results: MSCT Urography Multiphase examination procedure with clinical kidney tumors in the radiology installation of Banyumas Hospital includes, the patient's supine feet first position, scanning area from the diaphragm to the symphysis pubis, using 50 ml of contrast media with 40 ml of saline flush. Scanning technique by taking the pre-contrast phase, corticomedullary phase, nephrography phase, equilibrium phase and delay phase. Scan the area of the corticomedullary phase from the diaphragm to the symphysis pubis to to simplify the scanning process because the tool protocol has already made full abdominal scan area settings and to evaluate the pattern of abdominal organ enhancement if there is a metastatic urothelial lesion other than the kidney. The use of four phases of post-contrast scanning is because the goals and functions of each scanning phase are different so that the maximum diagnostic information is obtained.Conclusions: The MSCT Urography Multiphase examination procedure with clinical kidney tumors in the radiology installation of Banyumas can provide optimal diagnostic information. 
Pengukuran Kualitas Citra Menggunakan Aplikasi ImageJ pada Gambaran Vertebra Lumbosacral dengan Proyeksi Lateral Posisi Supine Kasus Low Back Pain (LBP) Aristia Wianing Putri
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10272

Abstract

Background: This study aims to determine the measurement parameters of the imageJ software which can assess the quality of radiographic imae on clinical lumbosacral vertebra examination LBP by using a sample of radiographic image that has been obtained. This research conducted from March to April 2022 at STIKES An Nasher Cirebon.Methods: Study this method uses of pixel values obtained by the device imageJ software on images without any treatment, smoothing, sharpening, and brightness.Result: With the result obtained in smooth treatment did not differ when compared with no treatment an sufficient seen when compared with the sharpen treatment, in the enhance treatment 0%, 0.3%, 0.5%, and 1.0%, the higher the enhance value range, the bigger the pixel value and there is no overlap between the enhance values of 0%, 0.3%, 0.5%, and 1.0%, and at brightness treatment differences in brightnesss I is not much different from brightness III, except for brightness I and II, the difference is clearly visible in the graphic values.Conclusions: In this study it was found that the results of radiographic image that were treated with smoot, sharpen, enhance, and brightness with no treatment smoot, sharpen, enhance, and better brightness of radiographic image results with smoot, sharpen, enhance, and brightness and can establish a clearer diagnosis.
Reduksi Dosis Serap Mata dengan Implementasi Software Organ Dose Modulation (ODM) pada Protokol CT Scan Sinus Paranasal Ade Irma Handayani; Dwi Rochmayanti; Bagus Dwi Handoko
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 2: JULY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i2.10408

Abstract

Background: CT Scan examination of the paranasal sinuses includes organs that are sensitive to radiation exposure, one of which is the lens of the eye whose damage can be known after radiation exposure of about 500 mGy. Currently found an alternative to reduce the dose received by patients is with Organ Dose Modulation (ODM) software This ODM serves to reduce radiation dose in the eye -18.9%, Brain -10.1%, Breast -31.3%, Lung -20.7% and Liver -24%. The purpose of this study is to determine the role of ODM software in dose reduction on CT Scan SPN, determine the amount of absorption dose profile with the implementation of ODM software, differences in anatomical image information with the implementation of ODM software and without ODM on CT Scan SPN.Methods: This type of research is quantitative with experimental studies, comparing the use of software with and without ODM to absorption dose reduction and anatomical image information of SPN. Samples using phantom performed Paranasal Sinus CT Scan procedure. Respondents consisted of 3 radiologists to assess the anatomical image of the maxillaris bone, bilateral maxillar sinus, and rice septum. Data analysis was carried out by statistical tests using SPSS Software to find the value of significance differences.Results: The use of ODM software on CT scans of the paranasal sinuses plays an important role in reducing the absorbed dose of the eye. Statistical test results showed a significant reduction in eye absorption dose (p-value 0.05). The dose profile resulting from the use of the ODM software is a decrease in the absorbed dose by the eye by 9.75%. The value of differences in SPN anatomical information using and without ODM resulted in a p-value of 1.00 (p-value 0.05).Conclusion: The value of the absorbed dose of eye radiation is significantly different with and without the use of ODM. However, there is no significant difference in the SPN anatomical image information. From the implementation of the ODM software, it can reduce the absorbed dose in the eye without reducing the anatomical image information.

Page 1 of 1 | Total Record : 9