Claim Missing Document
Check
Articles

Found 5 Documents
Search

Capability of Vitamin E as a Radioprotector in Suppressing DNA Damage Determined with Comet Assay Darlina, Darlina; A., Lusy Dahlia; Alatas, Zubaidah; Kisnanto, Teja; Syaifudin, Mukh
Biosaintifika: Journal of Biology & Biology Education Vol 9, No 2 (2017): August 2017
Publisher : Department of Biology, Faculty of Mathematics and Sciences, Semarang State University . Ro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/biosaintifika.v9i2.8333

Abstract

Radiation has a potent to damage cells. Radiation may act directly or indirectly on deoxyribonucleic acid (DNA) that results in the degeneration of tissues and necrotic, and thereby it needs a potent radioprotector to prevent these damages. Vitamin E is natural product known as an antioxidant which has potential as radioprotector. This research aimed to determine the capability of vitamin E with emphasized on the searching for its optimal concentration as radioprotector of DNA damage. This study used blood samples of healthy person irradiated with gamma rays at a dose of 6 Gy as the lethal dose to lymphocytes. The cocentrations of vitamin E from 0 to 0.8 mM was added into blood 15 minutes before irradiation. Isolation of lymphocytes was done using gradient centrifugation method. Evaluation on the capability of this compound in suppressing DNA damage was done by using alkaline Comet assay and data analysis was done using CaspLab program. The results show that addition of vitamin E could suppres these DNA damages and 0.8 mM of vitamin could reduce DNA damage up to 94.2%. We conclude that vitamin E effectively suppresed DNA damages induced by radiation. This information may benefit to the patient from negative impacts of radiotherapy.
Studi Awal Pengaruh Radiasi Terhadap Pekerja Radiasi Menggunakan Metode Comet Assay Oktavia S, Amel; Milvita, Dian; Darlina, Darlina
Jurnal Ilmu Fisika Vol 11, No 1 (2019): Published in March 2019
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (233.33 KB) | DOI: 10.25077/jif.11.1.8-12.2019

Abstract

Telah dilakukan studi awal pengaruh radiasi terhadap pekerja radiasi menggunakan metode comet assay. Pengambilan data dosis radiasi dilakukan pada hasil pembacaan laju dosis radiasi terhadap pekerja radiasi menggunakan film badge di Instalasi Radiologi RS Dr. Reksodiwiryo Padang, sedangkan pemeriksaan DNA sel limfosit dilakukan di Laboratorium Biomolekuler PTKMR BATAN. Pemeriksaan DNA sel limfosit dilakukan pada 50 sel sampel darah dari tiga orang pekerja radiasi dan tiga orang normal sebagai sampel kontrol, menggunakan mikroskop fluorescent dan CASP LAP comet assay software. Hasil pembacaan dosis radiasi menunjukkan bahwa laju dosis radiasi yang diterima pekerja radiasi yaitu 1,2 mSv/tahun. Hasil ini masih berada di bawah NBD berdasarkan Perka BAPETEN No 4 Tahun 2013. Pemeriksaan DNA sel limfosit menunjukkan nilai rata-rata tail length (TL) sampel pekerja radiasi lebih tinggi dibandingkan dengan sampel kontrol. Berdasarkan nilai TL tersebut belum bisa diketahui tingkat keparahan suatu kerusakan DNA.Kata kunci : laju dosis radiasi, NBD, kerusakan DNA , comet assay, limfosit, tail length
PEMBUATAN LARUTAN STANDAR DAN PEREAKSI PEMISAH KIT RIA T3 Darlina, Darlina
Jurnal Radioisotop dan Radiofarmaka Vol 1, No 2 (1998): JURNAL PRR 1998
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3634.009 KB)

Abstract

PEMBUATAN LARUTAN STANDAR DAN PEREAKSI PEMISAH UNTUK KIT RIA T3. Telah dilakukan pembuatan dan penentuan kualitas serum bebas T3, larutan standar, dan pereaksi pemisah untuk kit RIA T3. Serum bebas T3 yang digunakan sebagai larutan standar 0 dibuat dengan mengadsorpsi T3 pada "Charcoal" yang dicampurkan pada serum manusia. Serum bebas T3 yang diperoleh ternyata memberikan nilai persen ikatan (%B) = 53,9 % yang lebih tinggi dibandingkan dengan standar 0 kit komersil %B = 40,67%. Hal ini menunjukkan bahwa serum bebas T3 yang diperoleh cukup baik. Larutan standar T3 yang dibuat cukup baik dilihat dari hasil kalibrasi dengan larutan standar sekunder. Dilakukan pula pembuatan 3 macam pereaksi pemisah yaitu; Antibodi kedua yang dimurnikan dengan amonium sulfat yang diimobilisasi pada partikel magnetik (Hungaria); antibodi kedua "Fitzgerald" yang diimobilisasi pada partikel magnetik (Hungaria); dan antibodi kedua "Fitzgerald" yang diimobilisasi pada partikel magnetik "Fitzgerald". Dari perbandingan parameter kontrol dua macam antibodi kedua yang diimobilisasi pada partikel magnetik (Hungaria) menunjukkan kedua antibodi mempunyai kualitas yang sama. Pada perbandingan parameter kontrol partikel magnetik Hungaria dan magnetik Fitzgerald, diperoleh nilai persen Bo (34,6 %) dan NSB (3,2 %) untuk partikel magnetik Hungary yang lebih rendah dari % Bo (52 %) dan NSB (5,5%) partikel magnetik Fitzgerald tetapi nilai Bo/NSB (II) dan slopenya (1,3) lebih tinggi dibandingkan nilai Bo/NSB (9,5) dan slope (0,9) partikel magnetik Fitzgerald. Jumlah partikel yang dibutuhkan pertabung untuk partikel magnetik Fitzgerald cukup banyak (80 µg), sedangkan untuk partikel magnetik Hungaria hanya 16 µg. Kedua partikel mempunyai kelebihan dan kekurangan, tetapi partikel magnetik Hungaria lebih baik sebagai pendukung padat untuk pereaksi pemisah. Dari hasil studi banding, diperoleh bahwa kit RIA T3 dengan larutan pemisah Ab.kedua-Magnetik Hungaria mempunyai korelasi yang baik (99,1%) dengan kit RIA T3 komersial DPC. PREPARATION OF STANDARD SOLUTION AND SEPARATING REAGENT FOR T3 RIA KIT. Preparation of T3-free serum, standard solution and separating reagent have been carried out and tested. T3-free serum which was used as a solvent of T3 standards was prepared by addition of charcoal into human serum to adsorb the T3 hormon. Comparison of the T3-free serum with the standard 0 of a commercial RIA kit showed that the binding (%B) of the prepared T3-free serum was (53.9 %) higher than the commercial kit (40.67 %), indicated that the prepared T3-free serum was excellent. The T3 standard solutions prepared with the T3-free serum were calibrated against secondary standard solutions showed a reasonably good correlation, as there was no significant difference observed against expected value. Assay performance of three different separating reagents, i.e : (NH4)S04-purified second antibodies immobilized onto Hungary magnetic particles, impurified Fitgerald second antibodies immobilized onto Hungary magnetic particles, and impurified Fitzgerald second antibodies immobilized onto fitzgerald magnetic particles, were compared. Comparison of control parameters of the purified and impurified second antibodies immobilized onto Hungary magnetic particles showed that both antibodies have similar quality. Hungary magnetic particles gave lower %B/T and %NSB (34.6%) and (3.2%) than Fitzgerald magnetic particles (52%) and (5.5%) however higher Bo/NSB and slope (9.5 and 0.9) were observed for Hungary magnetic particles as compared to Fitzgerald's (11 and I.3). For a sufficient separation, the required amount of Hungary magnetic particles per assay tube was much lower (16 µg) than of Fitzgerald magnetic particles (80 µg). Therefore, it is considered that the Hungary magnetic particles was a better solid phase separating reagent. Assay comparison between the prepared T3 RIA reagent and a commercial (DPC) T3 RIA kit showed a very well correlation (99.I %).
EVALUASI KIT TSH IMUNOASSAY KOMERSIL DI INDONESIA Darlina, Darlina
Jurnal Radioisotop dan Radiofarmaka Vol 1, No 1 (1998): Jurnal PRR 1998
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3139.176 KB)

Abstract

EVALUASI KIT TSH IMUNOASSAY KOMERSIL DI INDONESIA. Telah dilakukan perbandingan dan penampilan sejumlah kit TSH komersil di Indonesia sebagai pedoman bagi pemakai dalam memilih metode dan kit yang paling sesuai dengan tujuan penggunaannya. Kit yang dipilih untuk penelitian ini terdiri dari bermacam variasi metodologi imunoassay yaitu; RIA magnetik (Amerlex-M, Amersham), IRMA coated well (Amerwell, Amersham), IRMA coated tube (DPC), IRMA microcellulose particle (Netria), dan ELIA (Amerlite, Amersham). Parameter yang dievaluasi adalah; limit deteksi, working range (kisaran daerah kerja),"recovery", presisi, intra assay dan inter assay, dan kemampuan untuk membedakan hipotiroid, normal, dan hipertiroid. Limit deteksi yang rendah ditemukan pada semua kit IRMA (≤ 0.05 mIU/L). Limit deteksi yang terendah ditemukan pada ELIA (0.012 mIU/L), dan yang tertinggi pada RIA magnetik (0.164 mIU/L). TSH IRMA Amerwell ternyata mempunyai kisaran daerah kerja yang terluas (0 - >500 mIU/L), sedang kisaran daerah kerja yang tersempit ditemukan pada RIA magnetik (3-110 mIU/L). Presisi yang terbaik ditemukan pada RIA magnetik dan ELIA yaitu %CV inter assay < 10% dan intra assay < 8%. Metode yang lain mempunyai presisi yang cukup baik yaitu; %CV inter assay < 15%, dan intra assay < 10%. Semua metode mempunyai kemampuan untuk membedakan hipo, normal, dan hipertiroid kecuali RIA magnetik yang tidak dapat membedakan normal dan hipertiroid secara jelas. Ni1ai "recovery" yang cukup baik ditemukan pada semua metode (90% - 120%) kecuali untuk RIA magnetik yang nilai "recovery' nya hanya 81%. Dari hasil penelitian ini dapat disimpulkan semua metode yang dievaluasi memberikan hasil yang handal untuk pengukuran sampel dengan konsentrasi yang sangat rendah hingga sangat tinggi, kecuali pada RIA magnetik yang memerlukan pengenceran untuk pengukuran sampel dengan konsentrasi yang sangat tinggi. EVALUATION OF COMMERCIAL TSH IMMUNOASSAY IN INDONESIA. An evaluation and comparison of the performance of a number of commercially available TSH kits in Indonesia have been made to guide the potential users in selecting the methods and kits most suitable for their intended purpose. The kits selected for this study comprise a wide variety of immunology methodology: magnetic RIA (Amerlex-M, Amersham), IRMA coated well (Amerwell, Amersham), IRMA coated tube (DPC), microcellulose particle IRMA (Netria), and ELIA (Amerlite, Amersham). The parameters of performance evaluated are: detection limit, working range, recovery, within and between assay precision, and the capability to distinguish hypothyroid, normal and hyperthyroid subjects. Reasonable detection limits are found with all IRMA kits (<0.05 mIU/L). ELIA showing lowest detection limit (0.012 mIU/L) and magnetic RIA the highest (0.164 mIU/L). Amerwell IRMA TSH was found to have the widest working range (0 - > 500 mIU/L) while magnetic RIA the narrowest (3 - 110 mIU/L). In term of the precision, magnetic RIA and ELIA have the best value, < 10% for between assay and < 8% for within assay, however all other methods also have sufficiently good precision (<15% and 10% respectively for between assay and within assay). All methods have the capability to identify hypothyroid, normal, and hyperthyroid subjects except for magnetic RIA which does not clearly distinguish between normal and hyperthyroid subject. Reasonably good recovery (90% - 120%) was obtained with all methods, except for magnetic RIA with only 81% recovery. It can be concluded that except magnetic RIA, all methods evaluated give useful and reliable results for measuring very low to very high concentration without dilution of sample. Magnetic RIA TSH gives meaningful results only for normal and high TSH concentration with necessary dilution for very high TSH concentration.
EVALUASI TIGA JENIS PARTIKEL MAGNETIK SEBAGAI PENDUKUNG FASA PADAT PADA RIA T3 Darlina, Darlina; Rediatning, Wayan
Jurnal Radioisotop dan Radiofarmaka Vol 2, No 1/2 (1999): JURNAL PRR 1999
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3884.603 KB)

Abstract

EVALUASI TIGA JENIS PARTIKEL MAGNETIK SEBAGAl PENDUKUNG FASA PADAT PADA RIA T3. Telah dilakukan evaluasi tiga jenis partikel magnetik yaitu; partikel selulosa magnetik, partikel magnetite, partikel IAE-silanised iron oxide sebagai pendukung fasa padat pada RIA T3. Evaluasi dimaksudkan untuk mendapatkan pereaksi pemisah yang kualitas assaynya baik, prosedur pembuatannya sederhana, dan biayanya murah. Metode evaluasi dilakukan melalui tahap; imobilisasi antibodi kedua pada partikel, optimasi imobilisasi, desain assay, dan evaluasi tampilan assay yaitu; % Bo, %NSB, kisaran daerah kerja, dan konsentrasi serum kontrol. % Bo yang tertinggi diperoleh pada partikel selulosa magnetik, dan ikatan tidak spesifik (NSB) yang terendah pada partikel magnetit. Partikel magnetite mempunyai daerah kerja yang terluas sedang yang tersempit diperoleh pada partikel IAE-silanised iron oxide. Hasil pengujian konsentrasi tiga macam serum kontrol (kontrol 1, kontrol 2, kontrol 3) masih dalam kisaran yang diperbolehkan, Tampilan assay partikel magnetite dan selulosa magnetik mempunyai kualitas yang sama tetapi jumlah partikel pertabung pada partikel magnetite jauh lebih kecil dan butiran partikelnya paling halus. Dari evaluasi ketiga partikel yang terbaik adalah partikel magnetite. THE EVALUATION OF THREE KINDS MAGNETIC PARTICLE AS A SOLID SUPPORT PHASE IN RIA T3. Evaluation has been carried out in three kinds magnetic particles i.e : cellulose magnetic particle, magnetite particle, IAE particle-silanised iron oxide as solid phase support in RIA T3. The purpose of evaluation is to obtain separator reactant which has high quality assay, and simple production process, low cost. The evaluation is performed in the immobilisation of second antibody, on the particles optimisation, design assay, and the evaluation of assay performance i.e: %Bo, %NSB, estimation of the operation range, and the concentration of control serum. The highest %Bo obtained in magnetic cellulose particle, the lowest non specific bound is in magnetite particle. Magnetite particle has widest range operation and on the other side IAE-silanised iron oxide particle has the lowest one. Assays of three control serum (control 1, control 2, control 3) show that the concentration are in acceptable range. Magnetic particles is the best particles from the others. The assay performance of magnetite particle and magnetic cellulose particle are same even however the weight of particles per-tube in magnetite particle is much lower and the granulates are much smaller. Magnetite particles is the best ones of the three particles.