Tri M. W. Sir
Dosen pada Jurusan Teknik Sipil, FST Undana

Published : 42 Documents Claim Missing Document
Claim Missing Document
Check
Articles

PEMANFAATAN SUMUR RESAPAN UNTUK MEMINIMALISIR GENANGAN DI SEKITAR JALAN CAK DOKO Bunganaen, Wilhelmus; Sir, Tri M. W.; Penna, Chrestta
Jurnal Teknik Sipil Vol 5, No 1 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (128.049 KB)

Abstract

Penelitian ini bertujuan untuk mencari debit banjir setiap rumah dan debit yang akan ditampung oleh sumur resapan pada rumah-rumah di Kelurahan Oetete sekitar SMA N 1 Kupang, untuk meminimalisir genangan yang terjadi di jalan depan SMA N 1 Kupang. Dalam penelitian ini menggunakan data curah hujan 20 tahun terakhir dari stasiun curah hujan Lasiana, perhitungan debit banjir rencana mengunakan metode Log Perarson Tipe III dan Metode Gumble Tipe I. Sampel tanah pada lokasi studi diambil untuk uji permeabilitas di laboratorium. Berdasarkan pengujian tersebut diperoleh koefisien permeabilitas tanah (k) adalah 6,01x10-5 cm/detik. Sebagai contoh untuk rumah dengan tipe 8x10 memiliki diameter sumur resapan 1 meter dengan kedalaman sumur 3,3824 ≈ 3,5 m dan debit masukan 0,0007 m3/detik. Debit banjir yang terjadi pada rumah tipe 8x10 adalah 0,0014 m3/detik, setelah ada sumur resapan berkurang menjadi 0,0007 m3/detik, sehingga tereduksi banjir sebesar 50%. Hasil perhitungan diperoleh 25 buah sumur resapan dengan kedalaman bervariasi yaitu 1,5 m (4 buah); 2 m (3 buah); 2,5 m (4 buah); 3m (4 buah) untuk sumur resapan tunggal karena kedalaman sumur resapan ≤ 3 m dan kedalaman 3,5 m (2 buah); 4 m (2 buah); 6,5 m (1 buah); 9 m (1 buah); 9,5 m (3 buah) dan 21 m (1 buah) untuk sumur resapan paralel karena dari hasil perhitungan diperoleh kedalaman sumur resapan > 3m. Untuk sumur resapan paralel akan dibangun kedalaman mulai dari 1 m – 3 m sampai kedalaman sumur tepenuhi.
PENGGUNAAN BLOK PERSEGI TERMODIFIKASI DAN TRAPESIUM DALAM PERENCANAAN BETON MUTU TINGGI DAN SANGAT TINGGI Pah, Jusuf J.S.; Ratu Edo, Carysa R.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (555.996 KB)

Abstract

Tujuan dari penelitian ini adalah untuk mendapatkan tatacara perencanaan beton mutu tinggi dan sangat tinggi dengan menggunakan blok pendekatan persegi yang termodifikasi dan blok trapesium. Penelitian dimulai dengan studi literatur dan perhitungan luasan diagram interaksi tegangan regangan beton. Setelah itu dilakukan ekuivalensi antara luasan diagram interaksi tegangan regangan dan luasan blok pendekatan, kemudian diperoleh koefisien-koefisien penyesuaian. Langkah selanjutnya adalah menurunkan rumus yang mengandung koefisien penyesuaian untuk mendapatkan rasio tulangan perlu dan langkah yang terakhir adalah menyusun tata cara perencanaan beton bertulang mutu tinggi dan sangat tinggi. Mutu beton yang ditinjau dalam penelitian ini adalah beton dengan mutu 15 – 120 MPa. Untuk pendekatan persegi termodifikasi diperoleh koefisien penyesuaian β1 berkisar antara 0.68 sampai 0.98, dengan 0.68 merupakan nilai β1 untuk beton 120 MPa sedangkan 0.98 untuk beton 15 MPa. Nilai β1 tersebut adalah nilai yang aman karena telah sesuai dengan syarat nilai β1 menurut SNI 03-2847-2002 yaitu β1 ≥ 0.65.Untuk pendekatan trapesium diperoleh nilai koefisien α untuk penyesuaian luasan berkisar antara 0.16 sampai 0.63, sedangkan untuk koefisien penyesuaian titik berat (γ) berkisar antara 0.0061 sampai 0.0222. The purpose of the research is to obtained a design procedure for flexure design of high strength and ultra high strength concrete; using modified rectangular block and trapezoidal block approaches. Analytical and design equations were formulated for each of the approaches, then by equating area of the block with that of actual stress-strain diagram, and internal moment of the force of the block to that of the actual stress-strain diagram, characeristic coefficients of each aproach were determined and adjusted. The procedure was done on high and ultra-high strength concrete (fc’ in the range of 15 to 120 MPa. The value of β1 ¬–coefficient for modified rectangular block approach was found to be in the range of 0.68 to 0.98, where 0.68 is β1 for 120 MPa and 0.98 for 15 MPa. These values are safe as it complies with the value required for it by SNI 03-2847-2002 namely that β1 ¬¬must be greater than 0.65. For the trapezoidal block approach there are two coefficients. They are α, coefficient for the area adjustment and γ, coefficient for the adjustment of center of mass. The research yielded that α is in the range of 0.16 to 0.63 and γ is in the range of 0.0061 to 0.0222. Design procedure was then prepared using each of the approach based on their respective characteristic coefficients.
BAHAYA KEGEMPAAN DI WILAYAH PULAU ALOR Putra, Liberichie P.; Simatupang, Partogi H.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 7, No 1 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (466.037 KB)

Abstract

Pulau Alor merupakan salah satu wilayah yang memiliki aktivitas seismisitas dan tektonik yang tinggi. Upaya mitigasi perlu dilakukan secara optimal guna meminimalisir dampak dari bencana tersebut. Analisis bahaya kegempaan dengan metode Probabilistic Seismic Hazard Analysis (PSHA) merupakan salah satu upaya mitigasi. PSHA bertujuan untuk mengetahui batasan intensitas gempa tertentu dengan berdasarkan pada nilai kemungkinan terlampui pada suatu periode tertentu. Tahapan penelitian meliputi kajian literatur, pengumpulan dan pengolahan data gempa, identifikasi sumber gempa, dan analisis menggunakan persamaan atenuasi. Data katalog gempa didapatkan dari United State Geological Survey (USGS). Persamaan atenuasi yang digunakan adalah Campbell & Bozorgnia (2008), Youngs et.al (1997), Boore & Atkinson (2003) dan Boore & Atkinson (2008). Hasil penelitian menunjukkan nilai percepatan tanah maksimum (PGA) di batuan dasar untuk Pulau Alor bervariasi dari 0,4849 g – 0,5260 g. Grafik respon spektrum hasil penelitian menunjukkan nilai yang lebih besar dibandingkan dengan grafik respon spektrum SNI-1726-2002 dan SNI-1726-2012. Berdasarkan peta gempa hasil penelitian menunjukkan Pulau Alor bagian timur memiliki nilai PGA terbesar, sedangkan Pulau Alor bagian barat memiliki nilai PGA terkecil.Alor Island is one of the high seismic and tectonic activity area. Optimal mitigation effort is needeful to minimize the disaster impact. Seismic hazard analysis in Probabilistic Seismic Hazard Analysis (PSHA) method is that one. The purpose of PSHA is to figure out the certain earthquake’s intensity with based on the exceed of probabilistic’s value at certain periods. The Stage of study include literature study, collecting and processing seismic data, identifies of earthquake’s source and analysis with attenuation equation. Earthquake katalog data from United State Geological Survey (USGS). Attenuation equation used Campbell & Bozorgnia (2008), Youngs et.al (1997), Boore & Atkinson (2003) dan Boore & Atkinson (2008). The result of this study shows the peak ground acceleration (PGA) in bed rock for Alor Island varied from 0,4979 g – 0,5680 g. Spectrum response graph from result of study is greater than spectrum response graph from SNI-1726-2002 and SNI-1726-2012. Based on the result of earthquake map study shows eastern of Alor Island have largest PGA value, while in the western of Alor Island have the smallest PGA.
ANALISIS PENGARUH PENGGUNAAN ABU BATU APUNG SEBAGAI PENGGANTI FILLER UNTUK CAMPURAN ASPAL Kumalawati, A.; Sir, Tri M. W.; Mastaram, Yovinianus
Jurnal Teknik Sipil Vol 2, No 2 (2013): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (202.381 KB)

Abstract

East Nusa Tenggara province is a region abundant with pumice content. Pumice is a frothy lava composed of compacted glass pyroclastic with very mikrovesikular wall extrusive igneous volcanoes bubbling, very thin and translucent and that is a common product of volcanic eruption and the general shape of the zones of the upper silicate lava They uses of pumice, among others: metal , raw material, lightweight brick, paint, plaster material, ceramics, sand paper raw materials and much more, pumice stone contain silica so that it can be used as a subtitude filler in asphalt mixture. This research was conducted to determine the effect of using pumice stone ash as a substitute filler in asphalt mixture. It will be seen from the value of stability and flow by using Marshall. There are several steps in Marshall’s method need to be done include: testing gravity, aggregate gradation planning, aggregate composition plane, aggregate bulk density calculation, the maximum mixture specific test and the calculations of the parameter values in Marshall’s method. The results of these research are finding higher levels of filler in asphalt mixture, the higher value of the stability while the value of flow decreases with increasing value of filler content in the asphalt mixture. Based on test results, the value of the variation of filler that meets spesifications Marshall’s is 1% and 2%, as only two variations of these filler levels that meet all of parameter value Marshall.
PENGUJIAN KUAT TEKAN DAN KUAT LENTUR MATERIAL PENGGANTI KAYU DENGAN CAMPURAN SERAT NILON Hunggurami, Elia; Sir, Tri M. W.; Lau, Maria I. K. K.
Jurnal Teknik Sipil Vol 4, No 2 (2015)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (191.81 KB)

Abstract

Kayu dimanfaatkan untuk memenuhi berbagai kebutuhan manusia sebagai bahan konstruksi. Pemanfaatan ini berdampak pada penebangan hutan dan menimbulkan kerusakan lingkungan. Untuk itu, diperlukan alternatif lain bahan konstruksi sebagai pengganti kayu. Penelitian ini bertujuan untuk mengetahui kuat tekan dan kuat lentur dari material pengganti kayu dengan variasi campuran serat nilon. Penelitian ini dilakukan dengan metode eksperimen dengan 4 variasi campuran serat nilon yaitu: campuran 5%, 10%, 15%, dan 20% dari berat semen dengan perbandingan campuran 1 semen : 0.25 bubuk kertas : 1.25 air. Untuk uji tekan dibuat 12 benda uji dengan ukuran 200 mm x 50 mm x 50 mm. Benda uji yang digunakan pada pengujian kuat lentur adalah 12 benda uji dengan ukuran 600 mm x 50 mm x 50 mm. Dari hasil penelitian dan analisis data diperoleh nilai kuat tekan dan kuat lentur dari ke empat campuran tersebut adalah sebagai berikut: untuk hasil pengujian kuat tekan dari material pengganti kayu untuk variasi campuran serat nilon 5%, 10%, 15%, dan 20% berturut-turut adalah 4,58 MPa, 5,33 MPa, 6,90 MPa, 7,07 MPa. Sedangkan untuk Hasil pengujian kuat lentur material pengganti kayu dengan campuran serat nilon dengan variasi 5%, 10%,15% dan 20% campuran serat nilon dari berat semen berturut-turut adalah 3,45 Mpa 7,45 MPa, 9,25 MPa dan 10,65 MPa. Dengan demikian, hasil pengujian menunjukan peningkatan kekuatan, baik itu kuat tekan maupun kuat lentur ketika terjadi penambahan presentasi jumlah campuran serat nilon hingga 20% terhadap berat semen. Wood are used for meet human needs as a construction material. The utilization of wood impact to deforestation and environmental damage. Therefore, it needed another alternative construction materials instead of wood. This research aims to know the compressive strength and bending strength of the alternate materials of wood with variations mixture of nylon fibers. This research was conducted by an experimental method that used 4 mixtures of variation, namely: mixtures of nylon fiber 5%, 10%, 15% and 20% with the ratio mixture is: 1 cement : 0.25 pulp 1.25 water. Compressive strength testing was made 12 sampels with size 200 mm x 50 mm x mm. The sampels used in the bending test are 12 sampels with a size 200 mm x 50 mm x mm. From the research and analysis of data obtained by the compressive strength and bending strength testing of the mixture into four is as follows: for the compressive strength test results of the alternate material of with with mixture of nylon fiber 5%, 10%, 15% and 20% was 4.58 MPa, 5.33 MPa, 6.90 MPa and 7.07 MPa. As for the bending test results for a mixture of nylon fiber 5%,10%, 15% and 20% was 3,45 Mpa 7.45 MPa, 9.25 MPa 10.65 MPa. Thus, the test results showed an increase in both of compressive strength and bending strength, when an adition of a mixture of nylon fibers presentation amount to 20% of the weight of cement for the alternate material of wood.
PENGARUH SUBSTITUSI PARSIAL SEMEN DENGAN ABU TERBANG TERHADAP KARAKTERISTIK TEKNIS BETON Simatupang, Partogi H.; Sir, Tri M. W.; Kurniaty, Anna S.
Jurnal Teknik Sipil Vol 5, No 2 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (97.893 KB)

Abstract

Partly or totally substitution of cement with another environmentally products in making concrete become the alternative. In this research the composition of the fly ash used as a partial replacement of cement in concrete as much as 40% out of total mass of cement (High Volume Fly Ash Concrete) and then will be compared with normal concrete about the technical characteristics of the two types of concrete. The purpose of this research was to determine the effect of partial replacement of cement with fly ash in concrete on technical characteristics of concrete which are specific gravity of concrete, compressive strength of concrete and concrete abrasion. The results obtained by the technical characteristics of concrete at the concrete age of 56 days for normal concrete has an average of specific gravity is 2434.39 kg/m³ with an average of compressive strength is 22.72 MPa and concrete abrasion percentage is 19.74%, for HVFA concrete has an average of specific gravity is 2407.22 kg/m³ with an average of compressive strength of 22.51 MPa and concrete abrasion percentage is 20.12%. The result of this research shows that the effect of the partial replacement of cement with fly ash in concrete produce the technical characteristics of concrete which are specific gravity of concrete, compressive strength of concrete and concrete abrasion are similliar with the technical characteristics of normal concrete.
BIAYA KEMACETAN RUAS JALAN KOTA KUPANG DITINJAU DARI SEGI BIAYA OPERASIONAL KENDARAAN Bolla, Margareth E.; Yappy, Ricky A.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 6, No 1 (2017)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (476.44 KB)

Abstract

Congestion is one of unresolved problem in the major cities in the world, including in Indonesia. In Kupang City, including at Jend. Sudirman street, congestion happen at peak hours in the morning and afternoon. This study takes the case on two representative points at Sta. 00+750 and Sta. 01+418 and analysis for Vehicle Operating Costs (VOC) have done by per peak hour and then taken the average per point. Calculation of VOC refers to the similarities in Manual BOK 1995 method and LAPI ITB-PT. Jasa Marga method. Furthermore, by selecting the VOC, the largest from the two methods, are used to determine the amount of congestion cost per peak hour per vehicle by using the equation Tzedakis (1980). Based on the analysis, the result of VOC of Jend. Sudirman road is Rp. 8,938,-/hour for motorcycles (MC), Rp. 204,320,- /hour for vehicle car (LV) and Rp. 565,661,- /hour for heavy vehicles (HV), where bad Level of Service (LOS) happen at 6:30 to 7:30 pm, 09:00 to 10:00 am, 12:00 to 13:00 pm and 17:00 to 19:00 pm. In addition, total congestion costs is Rp. 723,241/vehicle/peak hour/trip
STUDI PENGEMBANGAN SISI UDARA BANDAR UDARA MALI KABUPATEN ALOR UNTUK JENIS PESAWAT BOEING 737-200 Samapaty, Andrew U. R.; Sir, Tri M. W.; Ramang, Ruslan
Jurnal Teknik Sipil Vol 4, No 2 (2015)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Saat ini bandara Mali dilayani oleh pesawat F-50 dengan jumlah seat 48. Peningkatan jumlah penumpang dari tahun ke tahun mengakibatkan pihak maskapai dan bandara harus memberikan penerbangan tambahan untuk melayani semua penumpang yang ada. Namun apabila kapasitas pesawat yang digunakan lebih besar akan dapat menampung jumlah penumpang yang ada. Untuk itu perlu dilakukan pengembangan khususnya pada sisi udara bandar udara Mali yang mencakup landas pacu (runway), landas hubung (taxiway) dan landas parkir (apron). Penelitian ini bertujuan untuk merencanakan landas pacu, landas hubung dan landas parkir bandar udara Mali agar dapat melayani pesawat terbang yang lebih besar yaitu Boeing 737-200. Data yang digunakan dalam penelitian ini berupa data sekunder antara lain : Data lalu lintas pesawat pada bandar udara Mali, karakteristik pesawat Boeing 737-200, temperatur lingkungan bandar udara, elevasi dan kemiringan landasan dan CBR tanah dasarnya. Analisa dimensi sisi udara bandar udara dilakukan berdasarkan aturan International Civil Aviation Organization (ICAO), sedangkan perencanaan tebal perkerasan landas pacu menggunakan metode U S Corps of Engineer (CBR) dan metode Load Classification Number (LCN). Dari hasil penelitian maka diperoleh dimensi sisi udara bandar udara Mali dengan panjang minimum landas pacu 2181 m, lebar landas pacu 30 m dengan bahu landasan 2 x 15 m, total tebal minimum lapisan perkerasan landas pacu untuk metode CBR sebesar 19,85 inci dan metode LCN sebesar 25 inci, lebar minimum landas hubung yang dibutuhkan 15 m sedangkan lebar saat ini 21 m sehingga tidak perlu dilakukan penambahan lebar dan ukuran apron 144 m x 84 m dengan daya tampung pesawat sebanyak 3 buah pesawat Boeing 737-200. Mali airport is served by Foker 50 plane with 48 seats capacity.Every years the passanger have been upgrading and the airline company have to supply the airport with more flight to accommodate all the passanger. But if the plane used have more capacity will be able to accommodate all the passanger. Therefore something must be added at the air side including runway, taxiway and apron.The research is aimed at planning of runway, taxiway and apron of Mali airport in order to be able to give the service for bigger planes such as Boeing 737-200.The used data in this research are secondary data such as : traffic planes information in Mali airport, the characteristic of Boeing 737-200, the temperature around the airport, runway elevation and slopeandsubgrade CBR. Analysis at the dimention of air side of the airport is done based on the International Civil Aviation Organization (ICAO). While the planning of the runway thickness used U. S Corps of Engineer methode (CBR) and Load Classification Number methode (LCN). The research results obtained airside dimention of Mali airport with the runway minimum length is 2181 m, runway width is 30 mwith the width of the runway shoulder is 2 x 15 m, the minimum thickness of the runway pavement with CBR methode is 19,85 inches and with LCN methode is 25 inches,the minimum width of the taxiway is 15 m needed but the present width of the Mali airport taxiway this time is 21 m, so it is no need to make it wider and The wide of the apron is 144 m x 84 m, with the patching capacity is for 3 plane of boeing 737-200.
ANALISIS KEBUTUHAN ANGKUTAN UMUM JALUR KOLHUA  BUNDARAN PU DAN BANGKITAN PERJALANAN PENDUDUK YANG MENGGUNAKAN KENDARAAN PRIBADI Yane, Magdalena B.; Sir, Tri M. W.; Hunggurami, Elia
Jurnal Teknik Sipil Vol 5, No 1 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (114.806 KB)

Abstract

Dalam melakukan perjalanan sehari-hari penduduk Kelurahan Kolhua dan sebagian penduduk Kelurahan Maulafa dan Oepura hanya terlayani oleh sarana angkutan pribadi dan angkutan umum (ojek). Penelitian ini bertujuan untuk mengetahui peluang penggunaan moda transportasi, besarnya jumlah permintaan pelayanan angkutan umum, jumlah kebutuhan armada angkutan umum dan faktor-faktor apa saja yang lebih berpengaruh terhadap bangkitan perjalanan penduduk menggunakan kendaraan pribadi. Hasil penelitian menunjukkan bahwa jumlah perjalanan penduduk berdasarkan moda transportasi di Kelurahan Kolhua, Maulafa dan Oepura adalah sebanyak 356 kali perjalanan atau sebesar 44,61% menggunakan kendaraan pribadi sedangkan sebanyak 182 kali perjalanan atau sebesar 22,81% menggunakan angkutan umum (ojek). Jumlah permintaan pelayanan angkutan umum adalah sebanyak 2057 permintaan dan jumlah armada yang dibutuhkan adalah 9 unit. Wilayah ini tidak dapat dimasukkan dalam wilayah pelayanan angkutan umum penumpang karena jumlah permintaan angkutan umum (D) < R.Pmin = 5000 permintaan dan jumlah kendaraan yang dibutuhkan, N = 9 < R = 20 unit. Dan diketahui faktor yang lebih berpengaruh terhadap bangkitan (jumlah) perjalanan penduduk yang menggunakan angkutan pribadi (Y) adalah variabel jumlah anggota keluarga yang bekerja/sekolah (X2) dan jumlah kendaraan (X3).
KUAT TEKAN BETON MENGGUNAKAN AGREGAT HALUS SUNGAI BENLELANG DAN SUNGAI LEMBUR SERTA AGREGAT KASAR SUNGAI LEMBUR Mau, Meihizkia Y.; Hunggurami, Elia; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 7, No 1 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (216.501 KB)

Abstract

Kebutuhan bahan bangunan untuk pekerjaan konstruksi terus meningkat sehingga kebutuhan akan material untuk pembangunan juga meningkat, salah satunya adalah beton. Kebutuhan akan material beton sangatlah tinggi sehingga perlu adanya eksplorasi tempat baru untuk pengambilan material beton.Masyarakat Alor yang bermukim di dekat aliran sungai memanfaatkan agregat sungai sebagai material beton.Biasanya pasir sungai yang digunakan oleh masyarakat berasal dari pasir sungai Benlelang di Kecamatan Alor Tengah dan pasir sungai Lembur di Kecamatan Lembur.Tujuan dari penelitiaan ini untuk mengetahui nilai kuat tekan betonyang menggunakan bahan agregat halus Benlelang dan Lembur serta agregat kasar Lembur dan membandingkan nilai kuat tekannya dengan beton yang menggunakan agregat Takari. Benda uji yang dipakai berbentuk silinder dengan diameter 15 cm dan tinggi 30 cm dengan mutu rencana 15 MPa dan 25 MPa dengan durasi curing 28 hari.Berdasarkan hasil pengujian kuat tekan untuk mutu beton 15 MPa dan 25 MPa yang direncanakan, nilai kuat tekan beton yang menggunakan agregat Takari lebih tinggi dibandingkan dengan Benlelang dan Lembur.The need for building materials for construction work continues to increase so that the need for materials for development also increases, one of which is concrete. The need for concrete material is so high there is a need for exploration of new places for concrete material retrieval. Alorcommunity who live near the river flow utilize river aggregateas a concrete material. Usually the river sand used by the community comes from the sand of the river Benlelang in the Sub-district south Alor and the sand of Lembur River in Lembur Sub-district.This study aims determine the compressive strength of concrete using fine aggregate Benlelang and Lembur and coarse aggregate Lembur and compare the value of compressive strength using Takari aggregate. Concrete test specimens that are used in the form of cylinder with diameter 15 cm and height 30 cm with quality plan 15 MPa and 25 MPa with curing duration 28 days. Based on the results of the compressive strength test for the planned concrete quality of 15 MPa and 25 MPa, The value of concrete compressive strength using fine aggregate Takari is higher than Benlelang and Lembur.