Pelatihan Inspection Preventive Maintenance (IPM) MRI Nani Lasiyah; M. Rio Oktaviano; Yeni Pertiwi; Nurhadziqoh; Romi Mulyadi; Rino Ferdian
Abdimas Universal Vol. 4 No. 2 (2022): Oktober
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Balikpapan (LPPM UNIBA)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/abdimasuniversal.v4i2.219

Abstract

In Indonesia, the quality assurance of medical devices is carried out by the Hospital Facility Maintenance Installation, abbreviated as IPSRS. Generally, IPSRS staff consists of Human Resources (HR) who have qualifications in Electromedical, Public Health, and Management qualifications. Human resources in charge of carrying out maintenance and repairs, hereinafter referred to as Preventive Maintenance Inspections (IPM) of medical devices, are human resources with electromedical qualifications. Magnetic Resonance Imaging (MRI) is an advanced medical device that combines computer technology, high magnetic fields (0.067.0 Tesla) and radio waves to produce cross-sectional images of the muscles of the human body. To prepare patient services in hospitals using an MRI tool, reliable human resources are needed in carrying out their HDI. For this reason, training on the HDI of this MRI equipment is needed. This HDI training was attended by 534 participants from all over Indonesia which was carried out through the Zoom Meeting Application. This training succeeded in increasing the ability of participants by 27.98% while the average satisfaction of training participants was assessed from 5 aspects, namely at 86.65%, so that the training carried out is in the very satisfactory category.
Quality Analysis of Pressure Measurement Automatic Sphygmomanometer and Non-automatic Sphygmomanometer Yeni Pertiwi; Nur Hadziqoh; Romi Mulyadi; Nabila Noria Putri; Rizki Eka Putra
EKSAKTA: Berkala Ilmiah Bidang MIPA Vol. 23 No. 03 (2022): Eksakta: Berkala Ilmiah Bidang MIPA (E-ISSN : 2549-7464)
Publisher : Faculty of Mathematics and Natural Sciences (FMIPA), Universitas Negeri Padang, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1088.576 KB) | DOI: 10.24036/eksakta/vol23-iss03/328

Abstract

Hypertension is the fifth leading cause of death in Indonesia. Hypertension occurs because the blood vessels are continuously experiencing high pressure. Medical device that supports doctors and other health workers in diagnosing hypertension is sphygmomanometer. Sphygmomanometer is an instrument for measuring blood pressure. Accuracy of blood pressure measurement is very important in diagnosing hypertension. An Error in measuring blood pressure will be fatal for patients, health workers, and health facilities. So that this study aims to analyze the quality of automatic and non-automatic sphygmomanometer. This research method is in form of quantitative research based on experiments. The data was taken by using direct measurements. Measurements were carried out by using the 2018 Ministry of Health work method. Quality assessment of the sphygmomanometer was taken based on the results of sphygmomanometer calibration analysis. Automatic sphygmomanometer with the OMRON brand got score 95 and the non-automatic sphygmomanometer with the ABN brand got score 97.3. The results of the analysis showed that both tools had high accuracy of pressure measurement and were within tolerance limits. So it can be concluded that both tools are feasible to use.
Analisis Uji Kesesuaian Pesawat Sinar X Radiografi Mobile Merk ALLENGERS Type MARS-6 SBM Nani Lasiyah; Yeni Pertiwi; Romi Mulyadi; Nofri Anto
STRING (Satuan Tulisan Riset dan Inovasi Teknologi) Vol 7, No 2 (2022)
Publisher : Universitas Indraprasta PGRI Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30998/string.v7i2.13922

Abstract

The advances in technology experience significant developments anually, especially in the medical devices in the form of mobile x ray. The use of mobile x-ray radiation in the field of radiodiagnostics for various medical purposes needs to pay attention to two aspects, namely the risks and benefits. Therefore, the radiation protection is needed to reduce the damaging effects of radiation caused by radiation exposure. To ensure the accuracy and safety in the use of X-ray radiation, calibration procedures or conformity tests are carried out periodically. This study performs a conformity test on a mobile general radiography machine ALLENGERS, type MARS-6 SBM, with serial number 2162 used to examine the patients. The results of the conformity test using the Collimator Test and coin markers, mobile X-ray were declared to have passed the test as seen in the results from measurements using a Lux Meter, namely 101 Lux, with the score of a coin marker collimator of 3%.
ANALISIS HASIL PENGUJIAN DAN KALIBRASI PARAMETER BLOOD PRESSURE PADA ALAT KESEHATAN BLOOD PRESSURE MONITOR Nur Hadziqoh; Yeni Pertiwi; Romi Mulyadi
Al Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sciences) Vol 11 No 1 (2022): Al-Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sci
Publisher : STIKes Al-Insyirah Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35328/kesmas.v11i1.2178

Abstract

Testing and calibration of medical devices are one of the efforts to ensure the quality of medical devices. Tests and calibrations have been carried out on the Blood Pressure Monitor (BPM) in the emergency room at one hospital. In this article, it will be explained how the stages in testing and calibrating the BPM tool are to get the results of the appropriate/unfit for the tool. It aims to provide knowledge and awareness to health workers as device users and patients on the implementation and importance of testing and calibration of medical devices. The method used is the Work Method from the Ministry of Health of the Republic of Indonesia in 2018. The test parameters consist of a physical examination test and the function of the tool as well as a Blood Pressure performance test at the systole pressure measurement points of 60, 80, 100, 120, 150, 200 mmHg and the diastole pressure point 30, 50, 65, 80, 100, and 150 mm Hg. The results of the physical examination and function tests were 100% good. The results of the blood pressure performance test 94% passed the test with the measurement uncertainty value below the tolerance threshold (± 5 mmHg). The 150 mmHg diastolic pressure measurement point has a measurement uncertainty value that exceeds the tolerance threshold so that the pressure point does not pass the test. Thus, the BPM medical device is declared suitable for use.
A ANALISIS KELAYAKAN ALAT SUCTION PUMP LABORATORIUM PERAWAT STIKES AL INSYIRAH PEKANBARU Yeni Pertiwi; Nur Hadziqoh; Romi Mulyadi; Apriliani
Jurnal Ilmu Keperawatan Vol 11 No 1 (2022): Al-Asalmiya Nursing: Jurnal Ilmu Keperawatan (Journal of Nursing Sciences)
Publisher : STIKes Al-Insyirah Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (301.61 KB) | DOI: 10.35328/keperawatan.v11i1.2176

Abstract

Suction Pump is a medical device that is used to suck fluids formed by body secretions such as blood, saliva, pus, mucus and others. In addition to the hospital, this tool is also used in the nurse's laboratory as a clinical practice tool for nursing students. All medical devices must be calibrated periodically. In this study, we will discuss how to calibrate the suction pump with the aim of knowing whether the suction pump in the laboratory is suitable for use or not. The research was conducted using work methods that have been determined by the ministry of health, including physical inspection and tool functions, electrical safety and measuring tool performance with the power of calculation parameters. The results showed that the results of the physical examination and the function of the tool were 10%, electrical safety inspection was 32% and the measurement of the tool's suction power was 50% so that the overall inspection of the tool obtained a score of 92% with the status of the tool being fit for use.
ANALISA PARAMETER FREKUENSI PADA PENGUJIAN DAN KALIBRASI ELEKTROSTIMULATOR Nur Hadziqoh; Romi Mulyadi; Nani Lasiyah; Muddasir Muddasir
Al Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sciences) Vol 12 No 1 (2023): Al-Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sci
Publisher : Institut Kesehatan dan Teknologi Al Insyirah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35328/kesmas.v12i1.2445

Abstract

An electrostimulator is a device that produces millions of tiny electrical signals that enter the body through an electrode that is placed on the surface of the skin near the affected area or above it. Electrostimulators are widely used to determine the response of nerve and muscle cells to certain electrical stimuli. In this study, the process of analyzing the frequency parameters in the testing and calibration of the electrostimulator was carried out in which the calibration was aimed to find out some deviations between the calibrated tool and the calibrator. The method used is the work method that has been determined by the Ministry of Health of the Republic of Indonesia, which includes physical inspection and tool functions, electrical safety and frequency measurement performance testing. For the results of this study on physical examination and tool function by 10%, for electrical safety checks the value obtained is 40%, performance testing is 50%.
Analysis of the use of mother and child health (mch) books by pregnant women in controlling stunting in the working area of Koto Baru community health center, Kuantan Singingi District Riski Novera Yenita; Rifa Yanti; Sandra Febriani; Romi Mulyadi
Riset Informasi Kesehatan Vol 11 No 2 (2022): Riset Informasi Kesehatan
Publisher : Sekolah Tinggi Ilmu Kesehatan Harapan Ibu Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30644/rik.v11i2.717

Abstract

The Maternal and Child Health Book (KIA) contains important information needed by mothers and children,The low utilization of the MCH handbook is still constrained by the lack of knowledge about the benefits of the MCH handbook and some mothers also think that the MCH handbook is just an examination notebook..Koto Baru Health Center is one of the health centers in the districtKuantan singingi whose KI coverage reaches 100%. The high coverage of K1 is not in line with the use of MCH books by pregnant women.This research aims to knowing determinants related to the use of Maternal and Child Health (KIA) books by pregnant women in stunting control in the Koto Baru Health Center Work Area, Kuantan Singingi Regency. Types of research quantitative research with analytical research design and using a cross sectional approach. The sample was taken by total sampling technique with a sample of 36 respondents. Data were analyzed by univariate and bivariate.Research results obtained respondents used the MCH book well (61.1%), highly knowledgeable (63.9%), positive perception (52.8%), received family support (55.6%) and received the role of health workers (72, 2%). The results of the chi square test showed that there was a relationship between knowledge (p = 0.002), perception (p = 0.001), family support (p = 0.003) and the role of health workers (p = 0.001)with the use of Maternal and Child Health books. Kepada Health workers to improve services such as provide counseling, promotion and continuous information to pregnant women about the contents of the MCH handbook and its benefits for mothers and children so that pregnant women know the condition of their pregnancy and immediately check with health workers if they experience problems in pregnancy.
Sosialisasi Pemeliharaan Alat Kesehatan Timbangan Bayi Pada Posyandu Petunjuk Kalbu Kelurahan Sukajadi Romi Mulyadi; Albirruni Siregar; Nursaka Putra; Nadia Angelin; Fajar Kurniawan
Abdimas Universal Vol. 6 No. 2 (2024): Oktober (In Press)
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Balikpapan (LPPM UNIBA)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/abdimasuniversal.v6i2.499

Abstract

Maintenance and calibration of medical devices tend to only be carried out when facing health center accreditation. This activity has not been carried out in a planned and continuous manner. Lack of socialization, limited distribution of personnel, and the number of calibration laboratories that do not meet the requirements. The target of community service is the Posyandu Petunjuk Kalbu which is a community health service located in Gang Dahlia, Sukajadi Village, where this posyandu group does not understand and know how to calibrate medical devices and has not been exposed to how to repair, maintain and calibrate internal medical devices. The method of community service activities is carried out by presenting materials, calibration practice activities, and reviewing the results of socialization activities, maintenance in the form of repairs and calibration of equipment, especially on baby scales. So that the community needs to be socialized about the management of care and use of medical devices on baby scales. The results of community service activities at the Posyandu Petunjuk Kalbu, cadres and the community were able to understand and know very well, as evidenced by the provision of pretest questions and posttest questions as many as 10 questions, where after the provision of materials the community was able to answer correctly from the 10 questions given with the highest answer value on question number 7 as many as 29 people. With the implementation of this community service, it is hoped that the posyandu cadres will have a good understanding of the repair and calibration of baby scales.
A ANALISIS KELAYAKAN ALAT SUCTION PUMP LABORATORIUM PERAWAT STIKES AL INSYIRAH PEKANBARU Yeni Pertiwi; Nur Hadziqoh; Romi Mulyadi; Apriliani
Jurnal Ilmu Keperawatan Vol 11 No 1 (2022): Al-Asalmiya Nursing: Jurnal Ilmu Keperawatan (Journal of Nursing Sciences)
Publisher : Institut Kesehatan dan Teknologi Al Insyirah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35328/keperawatan.v11i1.2176

Abstract

Suction Pump is a medical device that is used to suck fluids formed by body secretions such as blood, saliva, pus, mucus and others. In addition to the hospital, this tool is also used in the nurse's laboratory as a clinical practice tool for nursing students. All medical devices must be calibrated periodically. In this study, we will discuss how to calibrate the suction pump with the aim of knowing whether the suction pump in the laboratory is suitable for use or not. The research was conducted using work methods that have been determined by the ministry of health, including physical inspection and tool functions, electrical safety and measuring tool performance with the power of calculation parameters. The results showed that the results of the physical examination and the function of the tool were 10%, electrical safety inspection was 32% and the measurement of the tool's suction power was 50% so that the overall inspection of the tool obtained a score of 92% with the status of the tool being fit for use.
ANALISIS HASIL PENGUJIAN DAN KALIBRASI PARAMETER BLOOD PRESSURE PADA ALAT KESEHATAN BLOOD PRESSURE MONITOR Nur Hadziqoh; Yeni Pertiwi; Romi Mulyadi
Al Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sciences) Vol 11 No 1 (2022): Al-Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sci
Publisher : Institut Kesehatan dan Teknologi Al Insyirah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35328/kesmas.v11i1.2178

Abstract

Testing and calibration of medical devices are one of the efforts to ensure the quality of medical devices. Tests and calibrations have been carried out on the Blood Pressure Monitor (BPM) in the emergency room at one hospital. In this article, it will be explained how the stages in testing and calibrating the BPM tool are to get the results of the appropriate/unfit for the tool. It aims to provide knowledge and awareness to health workers as device users and patients on the implementation and importance of testing and calibration of medical devices. The method used is the Work Method from the Ministry of Health of the Republic of Indonesia in 2018. The test parameters consist of a physical examination test and the function of the tool as well as a Blood Pressure performance test at the systole pressure measurement points of 60, 80, 100, 120, 150, 200 mmHg and the diastole pressure point 30, 50, 65, 80, 100, and 150 mm Hg. The results of the physical examination and function tests were 100% good. The results of the blood pressure performance test 94% passed the test with the measurement uncertainty value below the tolerance threshold (± 5 mmHg). The 150 mmHg diastolic pressure measurement point has a measurement uncertainty value that exceeds the tolerance threshold so that the pressure point does not pass the test. Thus, the BPM medical device is declared suitable for use.