cover
Contact Name
Rudy Kurniawan
Contact Email
rudy14k@gmail.com
Phone
+6285267099660
Journal Mail Official
rudy14k@gmail.com
Editorial Address
Kampus Terpadu Balunijuk, Kecamatan Merawang, Kabupaten Bangka, Provinsi Kepulauan Bangka Belitung
Location
Kab. bangka,
Kepulauan bangka belitung
INDONESIA
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering)
ISSN : 23555068     EISSN : 26224852     DOI : https://doi.org/10.33019/jurnalecotipe
This scientific journal is called Jurnal Ecotipe (Electronic, Control, Telcommunication, Information, and Power Engineering) with clusters of science in the field of Electrical Engineering covering the field of Electronics, Control, Telecommunications, Information/Informatics, and Power Electricity. The schedule of scientific journal publication is planned 2 times / volume in a year, ie April and October. The author can come from institutions outside the Department or from within the Department of Electrical Engineering University of Bangka Belitung. Aim and Scope : Electronics, Electronic Materials, Microelectronic System, Control System Engineering, Instrumentation and Control Engineering, Robotics, Telecommunication, Modulation and Signal Processing, Antenna and Wave Propagation, Information Technology, Information Theory and Coding, Computer Engineering and Informatics, Electrical and Power Engineering, Transmission and Distribution, Renewable Energy.
Articles 172 Documents
PERBANDINGAN WATERFALL MODEL DAN METODE GENERIK DALAM MANAJEMEN PROYEK PERANGKAT LUNAK SISTEM PENGELOLAAN DANA BANTUAN OPERASIONAL SEKOLAH (BOS) (STUDI KASUS: MAN 1 KOTA LHOKSEUMAWE) Hari Toha Hidayat
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 3 No 1 (2016): Jurnal Ecotipe, April 2016
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v3i1.27

Abstract

Making the software is not an easy job. If we are going to make an application then the required expertise in programming. However, mastery in the field of programming is not enough should have knowledge of project management software. Project management is an important part of software development. The research methodology used the case study of the application making the management of school operational funds in MAN 1 Lhokseumawe. Comparison of two methods of design that is between a generic method with the Waterfall model of result whereby the generic has stages that detailed when compared with the Waterfall model of simple and modest. Based on the research conducted in the making of software projects with short time such as within 1 month then it is better to use the method Waterfall design. But if the work over a long period of about one year and applications are built complex and large then you should use a generic method
ANALISIS TRANSFER RATE WIRELESS LOCAL AREA NETWORK DENGAN STANDAR IEEE 802.11A DAN IEEE 802.11G PADA KANAL LINE OF SIGHT F Ammar; Hanafi Hanafi
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 3 No 1 (2016): Jurnal Ecotipe, April 2016
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v3i1.28

Abstract

WiFi works on the 2.4 GHz band and 5 GHz. WiFi standard that works at this frequency, among others IEEE802.11g and IEEE802.11a. In this study measured the download and upload transfer rate of data with standard IEEE802.11g and IEEE802.11a. Measurements carried out on the canal Line of Sight (LOS), using two laptops to connected with the Access Point (AP) standard IEEE802.11g and IEEE802.11a. The results were obtained, the IEEE802.11g standard, download and upload transfer rate highest data 2.662,54.KB / s and 2549.60 KB / s, and the lowest 484,50.KB / s and 477.40 KB / s, while the IEEE802.11a standard, the transfer rate of the highest data download and upload 8104.68 KB / s and 5744.24 KB / s, and the lowest was 872.24 KB / s and 465,38.KB / s. In IEEE802.11g standard, the transfer rate of download and upload data at the lowest signal to below 35% and 30%, of the transfer rate of data downloads and uploads the highest. In the IEEE802.11a standard, the transfer rate of download and upload data at the lowest signal quality to below 20% and 30%, of the transfer rate of data downloads and uploads the highest. Data download transfer rate capability Standard IEEE802.11a, 2-3 times better at the highest signal quality condition, and no more than 2 times the lowest signal quality condition, compared the ability of downloading data transfer rate standard IEEE802.11g. The ability of data transfer upload rate IEEE802.11a Standard, 1.4 to 3 times better in the conditions of the highest quality signal, and 1-3 times better at low signal quality conditions, than the ability to upload the data transfer rate standard IEEE802.11g.
ANALISA PENGENDALI HYBRID SLIDING MODE CONTROL DAN PID UNTUK MENGENDALIKAN CONCENTRATION PADA ISOTHERMAL CONTINUOUS STIRRED TANK REACTOR (CSTR) Ahmad Faizal; Dian Mursyitah; Ewi Imaredah; Muhammad Ikhsyan
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 5 No 1 (2018): Jurnal Ecotipe, April 2018
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v5i1.29

Abstract

Systems in industry often occur in performance or desired performance. One of them isothermal CSTR system where the system has not been able to work according to the desired set point 1 g.mol / litter, to achieve the set point then used the controller Sliding Mode Control in Hybrid with PID in identification with FOPDT method to lower the value steady state error From the controller obtained results where the Sliding Mode Control Hybrid PID is able to not achieve set point value 1 g.mol / litter with ts = 3.0446 seconds.
SISTEM INFORMASI OBJEK WISATA JELITIK KABUPATEN BANGKA BERBASIS WEBSERVER Fardhan Arkan
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 5 No 1 (2018): Jurnal Ecotipe, April 2018
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v5i1.30

Abstract

Bangka has a beautiful tourist destination and attract tourists to visit, especially coastal tourism. One of them is a tourist destination in the village of Jelitik with beautiful and interesting beach tourism potential and is in one lane so that tourists have many options when visiting. Jelitik has beach tourism from Rambak Beach, Pantai Tikus, Tanjung Pesona, Pesona Bay and Tikus Mas Beach which is well known and widely visited by local people around Bangka. Currently, Jelitik does not have information system to provide complete information about the existing tourist attraction so as to facilitate the tourists when visiting. With the information system of this tourist attraction will facilitate the outsiders who want to know about tourist destinations in Jelitik and can be accessed using the Internet and introduce the tourist attraction widely to increase tourist arrivals. The tourist information system will make tourism in Jelitik will be widely known and make tourists who visit will get complete information. The development of information system of this tourist object will be based on webserver for management. The system will also build maps and profiles of this tourist destination is expected to introduce tours in Jelitik widely to the public using the Internet
ANALISIS TEKNO EKONOMI PERANCANGAN 4G LTE DI KABUPATEN BANYUMAS Abny Irawan; Alfin Hikmaturokhman; Dadiek Pranindito
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 5 No 1 (2018): Jurnal Ecotipe, April 2018
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v5i1.31

Abstract

Banyumas Regency has a very rapid development with the progress in knowledge education. The development of Banyumas Regency, it is also necessary to improve the telecommunication service that is feasible. Indosat is one of the operators of 4G LTE technology developers using 1800Mhz frequency. Planning is using atoll software with reference to downlink, uplink and volume requirement of data needed by considering demography factor and projection of user in Banyumas Regency. The calculation of LTE technology deployment scheme based on Banyumas Regency area coverage requires 124 sites, while calculation based on capacity needs 71 ??sites in 2016. Simulation result using atoll software shows average RSRP value -80.9dBm and SINR value 0.64dB. Services at simulation atoll software that used by customers in Banyumas District is IMS Signaling 14,639 people, streaming media 34,348 people, video phone 65,731 people, real time gaming 20,637 people, video conference 66,325 people and voice over IP service 134,331 people. CAPEX covers is eNodeB device costs, license, Installation and loan capital. OPEX includes Operational & Maintenance, Rental backhaul, HR cost, Interconnection fee, marketing fee, general administration fee & Frequency BHP. Depression assumption for 10 years. The funding structure is the assumption of 60% loan & 40% own capital. The loan interest rate is 7.5% per annum with the assumption of a 5 year loan repayment. Annual tax of 25%. WACC of 12.5%. Cost benefit calculation yields 3% IRR and NPV Rp-8,729,606,072. So the design of LTE deployment in Banyumas regency for 15 years has not received a payback period or is still a loss.
PENINGKATAN AREA JANGKUAN JARINGAN 4G LTE (STUDI KASUS KECAMATAN SAMARINDA ULU) Maria Ulfah
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 5 No 1 (2018): Jurnal Ecotipe, April 2018
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v5i1.32

Abstract

Improving the quality of the telecommunication network of 4G LTE technology must always be done considering the needs and the number of users (users) who have increased as well. In this research, optimization of coverage area (coverage area) in Samarinda Ulu District by using Atoll software. The design of the area scope uses 12 E Node B using 2 scenarios are Antenna 65deg 17dBi 0Tilt 1800MHz (Scenario 1) and Antenna 65deg 17dBi 2Tilt 1800MHz (Scenario 2). The total area for scenario 1 is 22,772 km2 while for the area for scenario 2 is 22,698 km2. . The difference of area between scenario 1 and scenario 2 is 0,074 km2 . Scenarios 1 and 2 can reach the Samarinda ulu subdistrict in densely populated sites.
PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP STABILITAS STEADY STATE Asmar Asmar
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 5 No 1 (2018): Jurnal Ecotipe, April 2018
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v5i1.33

Abstract

The stability of the electric power system is related to the balance of power in the system. When a power change occurs, the rotor will swing affecting the power angle, rotation speed, frequency and stability of the system. The Unbalanced load causes the momentary power of the generator to contain the sinusiodal component. To know the effect of sinusiodal component, must be known relation between power angle with momentary power. The relationship is determined by the symmetric component method. The power angle relationship with the momentary power obtained is applied to the swing equation. With the linearization of the equation, it can be seen the effect on steady state generator stability. The results showed that an increase in load imbalance caused a decrease in the stability limit.
IMPLEMENTASI MOBILE AUGMENTED REALITY 3 DIMENSI PADA PETUNJUK PRAKTIKUM DRIVE TEST Alfin Hikmaturokhman; Satrio Adi Wiguna; Elisa Usada
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 2 No 2 (2015): Jurnal Ecotipe, Oktober 2015
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v2i2.34

Abstract

Nowaday technology has been growing up in. One of them is cellular technology, the increasing of mobile technology requires the better service. To overcome these problem, the operator have to do Drive Test to identify and analyz the network quality of service, to improve the learning activities about Drive Test then needed an option for it. It can be overcome by the module Drive Test lab manual with applications that can support the user with an attractive visual display. The application materials will be designed on the basis of such a simulation about Drive Test Handover process, the process occurs as a result of Drop Call or constraints of a mobile network that frequently appear on the user's mobile phone, and the basic steps Drive Test. This lab manual application modules is created using a mobile Augmented Reality technology. The method which is used for the development of systems using waterfall SDLC (System Development Life Cycle). The visualization of the application made by Blender 2.69 using 3D objects. This application adds to the user experience more with 90.31% index points of total maximum of 100% which indicates that the application is easy to use and easy to be learned, This application works optimally if the light in a location that has a minimal emission of 3 Lux to 6 Lux for outdoor and indoor.
PEMODELAN SISTEM PEMBANGKIT LISTRIK HYBRID DIESEL GENERATOR DAN PHOTOVOLTAIC ARRAY MENGGUNAKAN PERANGKAT LUNAK HOMER (Studi Kasus di Pulau Semujur Kabupaten Bangka Tengah) Dedisukma Dedisukma; Wahri Sunanda; Rika Favoria Gusa
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 2 No 2 (2015): Jurnal Ecotipe, Oktober 2015
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v2i2.35

Abstract

Hybrid system is one way in saving the use of petroleum fuels with solar power generating systems apply settlement in Semujur island where it is currently available diesel generator in operation for 3 hours/day with an average power in each house of 178.8 Watt by using a hybrid system modeling software HOMER 3.2.3 the calculation of the cost for the operation the hybrid system. Results of the simulation HOMER that potential energy produced by the photovoltaic array system with lowest solar insolation values on Semujur island amounted to 3.99 kWh/m2/day with renewable fraction in the photovoltaic array system configuration by 34% generating electrical energy by 15515.01 kWh/year with diesel fuel savings of 64.3% of total oil consumption currently operates its own diesel generator spend net present value cost (NPC) Rp 1.143.972.000 and cost of energy (COE) 3,380 Rp/kWh and has advantages sufficient electrical energy for the growth of a population 7 houses in the future.
EVALUASI KEANDALAN SISTEM DISTRIBUSI PADA PENYULANG CEKO (FEEDER 3) GARDU INDUK PANGKALPINANG PLN AREA BANGKA Dedi Syah Putra; Wahri Sunanda; Rudy Kurniawan
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 2 No 2 (2015): Jurnal Ecotipe, Oktober 2015
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/ecotipe.v2i2.36

Abstract

One of main components in the electric generation system is distribution system. it have function, distribute the energy to customers more continuously and well. To evaluate it reliability for feeder 3 in PLN Area Bangka before and after using SCADA seized by reliability of distribution SAIDI, SAIFI, and CAIDI system index. The test result based on sample of SAIDI, SAIFI, and CAIDI index before using SCADA method at 2013 is 2,77 time/year for SAIFI index, 6,21 hours/year for SAIDI index, and 2,242 hours/year for CAIDI index. Meanwhile for after using SCADA method at 2014 is 10,32 time/year for SAIFI index, 19,18 hour/year for SAIDI index, and 1,858 hours/year for CAIDI index.

Page 3 of 18 | Total Record : 172