cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Radioisotop dan Radiofarmaka
ISSN : -     EISSN : -     DOI : -
Core Subject : Health,
Jurnal Radioisotop dan Radiofarmaka (Journal of Radioisotopes and Radiopharmaceuticals) bertujuan untuk memajukan ilmu pengetahuan dan teknologi di bidang radioisotop, radiofarmaka dan bidang terkait, yang diwujudkan dalam bentuk makalah ilmiah hasil penelitian atau tinjauan dan gagasan.
Arjuna Subject : -
Articles 4 Documents
Search results for , issue "Vol 3, No 1 (2000): JURNAL PRR 2000" : 4 Documents clear
CHROMATOGRAPHIC BEHAVIOUR OF CADMIUM-(II) IN HYDROUS CERIC OXIDE COLUMN Soenarjo, Sunarhadijoso; Yantih, Novi; Sinambela, James; Pujianto, Anung; Sarwono, Daya Agung
Jurnal Radioisotop dan Radiofarmaka Vol 3, No 1 (2000): JURNAL PRR 2000
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3079.627 KB)

Abstract

CHROMATOGRAPHIC BEHAVIOUR OF CADMIUM-(II) IN HYDROUS CERIC OXIDE COLUMN. The potential of hydrous ceric oxide (HCO) in the immobilization of cadmium ions enables the compound to be used as an adsorbent for recovering 112Cd target in the production of medical radioisotope 111ln. Since the enriched-112Cd is very expensive, the dynamic sorption of 112Cd in HCO column needs to be evaluated. In the presented work, the HCO was synthesized through the reaction of ceric Sulphate and ammoniac solution. The reaction product was then heated and dried at 1000C to give HCO. A series of Cd(II) standard solutions was loaded onto HCO columns followed by fractional elution and determination of Cd(II)-content in each eluate fraction. The quantitative determination of Cd(II) content was performed by UV-spectrophotometry at 301 nm with a standard regression curve expressed as A = O.OOO1C - 0.0002. The chromatographic behaviour of Cd(II) in HCO column was characterized by dynamic sorption capacity, elution profile, recovery yield and total volume of the eluent. It appears that the dynamic sorption of Cd(II) increases if the HCO was treated with ammoniac solution instead of with 0.1 M HCL solution. By using NH4OH solutions (5 %, 10 % and 20 %) as eluents, it is shown that the concentration of NH4OH does not significantly affect the Cd(II)-elution profile. The recovery yield was obtained in the range of 94 to 100 %, while most the eluted Cd(II) was collected in the first and second- 2 mL fractions. PERILAKU KROMATOGRAFI KADMIUM-(II) DALAM KOLOM RESIN SERIUM OKSIDA. Potensi resin anorganik serium oksida (HCO) untuk mengikat ion kadmium mendorong kemungkinan pemanfaatan HCO dalam proses pemungutan ulang bahan sasaran 112Cd diperkaya yang digunakan dalam proses produksi radioisotop medis 111ln. Karena mahalnya bahan sasaran 112Cd tersebut, maka fenomena penyerapan dinamik 112Cd pada kolom resin HCO dipelajari dengan menggunakan Cd alam. Di dalam percobaan ini HCO disintesis melalui reaksi antara serium sulfat dengan larutan amonia. Produk reaksi dipanaskan dan dikeringkan pada suhu 100°C untuk mengubahnya menjadi HCO. Larutan standard Cd(II) dengan variasi konsentrasi dimasukkan ke dalam kolom HCO dan kemudian dilakukan elusi berfraksi diikuti dengan pemeriksaan kandungan Cd(II) dalam masing-masing fraksi eluat. Penentuan kuantitatif Cd(II) dilakukan dengan metoda spektrofotometri UV pada panjang gelombang 301 nm dengan persamaan regresi standar yang dinyatakan sebagai A = O,OOO1C - 0,0002. Sifat kromatografi Cd(II) dalam kolom HCO dipelajari melalui pengamatan terhadap 4 aspek yaitu kapasitas penyerapan dinamik, profil elusi, efisiensi elusi dan volume total eluen yang diperlukan. Didapatkan bahwa penyerapan dinamik Cd(II) pada kolom HCO yang diaktivasi dengan larutan HCL 0,1 M lebih rendah dibandingkan pada kolom HCO yang diaktivasi dengan larutan NH4OH (5 %, 10 % dan 20 %). Hasil percobaan menunjukkan bahwa penggunaan eluen NH4OH dengan konsentrasi 5 %, 10 % dan 20 % tidak memberikan perbedaan profil elusi Cd(II) yang signifikan. Dengan elusi berfraksi sebanyak 2 mL per fraksi eluat, didapatkan akumulasi Cd(II) terelusi pada 2 fraksi eluat pertama dengan efisiensi elusi antara 94 - 100 %.
IMMUNORADIOMETRICASSAY (IRMA) DALAM DETEKSI DAN PEMANTAUAN KANKER S., Wayan Rediatning; Dj, Sukiyati
Jurnal Radioisotop dan Radiofarmaka Vol 3, No 1 (2000): JURNAL PRR 2000
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3798.956 KB)

Abstract

IMMUNORADIOMETRICASSAY (IRMA) DALAM DETEKSI DAN PEMANTAUAN KANKER. Kanker merupakan masalah kesehatan yang cukup besar tidak saja di Indonesia, namun juga di seluruh dunia. Banyaknya kematian yang disebabkan kanker umumnya disebabkan karena terlambatnya diagnosis dan ketidaktepatan penanganan terapi. Untuk mengurangi angka kematian akibat kanker ini perlu diupayakan deteksi dini dan pemantauan kanker pada pasien yang menjalani terapi. Dalam kaitannya dengan hal tersebut diatas, pada makalah ini dibahas mengenai peran teknik Immunoradiometricassay (IRMA) dalam deteksi dan pemantauan kanker dengan penentuan kadar "tumor marker" dalam serum pasien. Disamping itu dikemukakan pula prinsip IRMA dalam penentuan kadar "tumor marker", kit IRMA yang ideal dalam penentuan kadar "tumor marker". Beberapa jenis kit IRMA yang digunakan untuk penentuan "tumor marker" dalam deteksi dan pemantauan kanker serta pemilihan "tumor marker" dalam diagnosis serta pemantauan kanker juga merupakan bahasan dalam makalah ini. Dari bahasan dalam makalah ini, dapat disimpulkan bahwa teknik IRMA sangat memegang peranan dalam deteksi dan managemen penanganan kanker melalui penentuan kadar "tumor marker" dalam serum pasien. IMMUNORADIOMETRICASSAY (IRMA) IN DETECTION AND MONITORlNG OF TUMOR. Cancer is becoming a serious health problem not onlv in Indonesia, but also all over the world. The high rate of death caused by cancer is mostly due to the late diagnosis and unproper management of cancer. To reduce the high rate of death due to cancer, the analytical technique which can be used for early detection and monitoring of cancer is required. Related to this matter, the role of Immunoradiometricassay (IRMA) in detection and monitoring of cancer through determination of tumor marker is discussed, The principle of IRMA for tumor marker detection and the requirement of ideal IRMA kit for tumor marker are also briefly described. Different kind of tumor maker IRMA kit and the choice of tumor marker in detection and monitoring of cancer are also included in this paper. It is summerized that IRMA technique plays important role in detection and monitoring of cancer through determination of tumor marker in pasien serum.
PENGEMBANGAN PROSES PRODUKSI MOLIBDENUM-99 HASIL FISI DENGAN MENGGUNAKAN TARGET FOIL LOGAM Uranium PENGKAYAAN RENDAH Mutalib, Abdul; Vandegrift, G. F.; Conner, C.; Gunawan, Adang Hardi; Lubis, Hotman; Sukmana, Ateng; Purwadi, Bambang; Wisnukaton, Khadarisman; Jatmiko, Diki Tri; Sriyono, Sriyono
Jurnal Radioisotop dan Radiofarmaka Vol 3, No 1 (2000): JURNAL PRR 2000
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (8009.772 KB)

Abstract

PENGEMBANGAN PROSES PRODUKSI MOLIBDENUM-99 HASIL FISI DENGAN MENGGUNAKAN TARGET FOIL LOGAM URANIUM PENGKAYAAN RENDAH. Badan Tenaga Nuklir Nasional dan Argonne National Laboratory dewasa ini sedang melaksanakan kerja sama penelitian dan pengembangan produksi molibdenum-99 dengan menggunakan foil logam uranium pengkayaan rendah. Pembahasan dalam makalah ini lebih difokuskan terhadap hasil kerja sama pengembangan dan penelitian tersebut yang telah dilaksanakan di Pusat Pengembangan Radioisotop dan Radiofarmaka. Dalam makalah dijelaskan (1) keberhasilan pemisahan dan pemurnian 99Mo dari target foil logam uranium pengkayaan rendah yang telah diiradiasi di reaktor RSG-GA Siwabesy, dan (2) keberhasilan memodifikasi proses Cintichem. Hasil pengembangan pendahuluan metoda kuantitatif elektrodeposisi cemaran uranium dan plutonium di dalam 99Mo juga akan dijelaskan. DEVELOPMENT OF PRODUCTION PROCESSES OF FISSION PRODUCT MOLYBDENUM-99 USING LEU METAL FOIL TARGETS. A collaboration is underway between Indonesian National Nuclear Energy Agency and Argonne National Laboratory to carry out R&D on the production of molybdenum-99 using LEU (Low Enriched Uranium)-metal foil targets. A review in this paper is focused mainly on the results of laboratory experiments conducted at the Center for Development of Radioisotopes and Radiopharmaceuticals, Serpong. It describes succeses in (1) performing separation and purification of 99Mo in the irradiated LEU-metal foil targets, and (2) modifying Cintichem procedure. A method for quantitatively electrodepositing uranium and plutonium contaminants in the 99Mo is also described.
UJI KUALITAS PRODUK I-131 HASIL BELAH U-235 Wisnukaton, Khadarisman; Suparman, Ibon; Gunawan, Adang Hardi; Lubis, Hotman; Ritonga, Togar Marsangap; Sukmana, Ateng; Tahyan, Yayan; Haffid, Dadang; Lestari, Enny; Sriyono, Sriyono; Herlina, Herlina
Jurnal Radioisotop dan Radiofarmaka Vol 3, No 1 (2000): JURNAL PRR 2000
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3666.88 KB)

Abstract

UJI KUALITAS PRODUK 131I HASIL BELAH 235U. Telah dilakukan uji kualitas terhadap 10 buah cuplikan produk 131I hasil belah 235U. Pemeriksaan cuplikan meliputi penetapan konsentrasi radioaktivitas 131I, pH, kemurnian radiokimia, kontaminasi radionuklida pemancar gamma dan alfa. Semua produk 131I hasil belah dalam percobaan ini pH-nya memenuhi persyaratan yang telah ditetapkan oleh Medi Physic Inc. Konsentrasi radioaktivitas 131I hasil belah 235U tidak ada yang memenuhi syarat. Sembilan cuplikan dari 10 cuplikan memenuhi persyaratan kemurnian radiokimia yang dianalisis dengan cara kromatografi kertas. Delapan cuplikan memenuhi syarat kontaminasi radionuklida pemancar alfa. Sebanyak 6 cuplikan produk 131I memenuhi syarat kontaminasi radionuklida pemancar gamma, dan ada 4 cuplikan yang tidak memenuhi syarat. Dengan demikian semua produk tidak ada yang memenuhi semua persyaratan sesuai dengan persyaratan yang telah ditetapkan oleh Medi Physic Inc. QUALITY CONTROL TESTS OF FISSION PRODUCT 131I. Quality control tests were carried out for 10 samples of fission product 131I obtained from irradiated high enriched uranium target (UI25 = 93%) from 235U. The analysis of samples covered the determination of 131I radioactivity concentration, pH of solution, and radiochemical purity as well as gamma and alpha radionuclide impurities. Results were compared to the Medi Physics quality requirements. The fission produced 131I samples in this experiment met the required pH value but no one met the required radioactive concentration. The radiochemical purity determined by paper chromatography method shows the yield more than 95 %. It was found that eight samples showed alpha emitter contaminants under the permissible value, and two others were higher than the permissible value.

Page 1 of 1 | Total Record : 4