cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kab. sleman,
Daerah istimewa yogyakarta
INDONESIA
Inersia : Jurnal Teknik Sipil dan Arsitektur
ISSN : 0216762X     EISSN : 2528388X     DOI : -
Core Subject : Engineering,
INERSIA is stand for INformasi dan Ekspose hasil Riset Teknik SIpil dan Arsitektur. This scientific journal is managed by the Department of Civil Engineering and Planning Education, Faculty of Engineering, Yogyakarta State University, in cooperation with the Persatuan Insinyur Indonesia (PII). It publishes and disseminates research results from lecturers and post graduate students from various universities in Indonesia, which has contributed to the development of science and technology, especially in the field of Civil Engineering and Architecture. INERSIA is published twice a year, in May and December.
Arjuna Subject : -
Articles 8 Documents
Search results for , issue "Vol 15, No 2 (2019): Desember" : 8 Documents clear
EVALUASI HUBUNGAN BIAYA INVESTASI TERHADAP KUALITAS KENYAMAN PADA PERUMAHAN Pratiwi Dian Ilfiani; Suprapto Siswosukarto; Djoko Sulistyo
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (504.977 KB) | DOI: 10.21831/inersia.v15i2.28621

Abstract

 ABSTRACTThe demand for housing has never stopped because the population growth  always increased. Technical Guidelines for the Construction of Healthy Houses issued by the Minister of Regional Regional Development states that a house as a place of residence must meet indoor health and comfort requirements which is influenced by lighting, airing, air temperature and humidity. This study uses natural lighting, natural ventilation, room humidity and acoustic comfort as variables. The object of this study is limited to the building area of a maximum of 70 m2 with four sample that maintain the original house shape from the design of the developer. Three out of four houses showed the relation between investment and indoor comfort, the higher investment improve indoor comfort. But, one of them showed different pattern, this is because the investment value is influenced by the accessibility of site and buildings.This study found that indoor comfort is influenced by design factors and micro climates. While home investment is influenced by the design and accessibility of site and buildings.Keywords: indoor comfort, lighting, natural ventilation, humidity, acoustic comfort ABSTRAK Tuntutan adanya sebuah rumah tidak pernah berhenti karena pertumbuhan penduduk yang selalu meningkat. Pedoman Teknis Pembangunan Rumah Sederhana Sehat yang dikeluarkan oleh Menteri Permukiman dan Prasarana Wilayah (2002) menyatakan bahwa rumah sebagai tempat tinggal yang memenuhi syarat kesehatan dan kenyamanan dipengaruhi aspek  pencahayaan, penghawaan, serta suhu udara dan kelembaban dalam ruangan. Adapun variabel yang diangkat terdiri dari pencahayaan alami, penghawaan alami, kelembaban ruang dan kebisingan. Objek dari penelitian ini dibatasi pada dengan luas bangunan maksimal 70 m2 dengan empat sampel rumah yang mempertahankan bentuk rumah asli dari desain pengembang. Dari empat rumah, tiga diantara menunjukkan hubungan bahwa semakin tinggi investasi semakin baik kualitas kenyamanan di dalamnya. Akan tetapi satu diantaranya memperlihatkan pola yang berbeda, hal tersebut dikarenakan nilai investasi yang dipengaruhi oleh nilai aksesibilitas lahan dan bangunan. Penelitian ini pada akhirnya mendapatkan hasil bahwa kenyamanan dalam ruang dipengaruhi oleh faktor desain rumah dan iklim mikro. Sedangkan investasi rumah dipengaruhi oleh desain dan nilai aksesibilitas lahan dan bangunan. Kata kunci: kenyamanan dalam ruang, pencahayaan, penghawaan, kelembaban, kebisingan
ANALISIS REGANGAN BAJA TULANGAN PADA STRUKTUR PILE CAP EMPAT TIANG METODE STRUT AND TIE MODEL Sukarman Sukarman; Djoko Sulistyo; Inggar Septhia Irawati
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (937.28 KB) | DOI: 10.21831/inersia.v15i2.28624

Abstract

 ABSTRACTPile cap is one of the many types of structures that are entirely Disturbed-region. The structure undergoes a non-linear strain because it was meeting point of the pile and column with centralized forces. In addition, geometry changes occur at the meeting between the column, pile cap, and pile, so the Bernoulli concept is no longer suitable for this condition. Pile cap testing consists of two groups of specimens and each group consists of three specimens. The first group was designed using the STM method (SNI 2847: 2013 Appendix A) and the second group was designed using conventional methods (SNI 2847: 2013 Article 15). Loading is the application of a centralized static load that is channeled through a centric column until the pile cap structure has collapsed. The results show that: (1) The flexural reinforcement which experiences the first yield condition both on the pile cap testing of the STM method and in the conventional method was the X direction flexural reinforcement (outsidest flexural reinforcement). (2) The average strain of the yield conditions and load on the pile cap STM method were 2242 με and 528.97 kN, whereas the conventional method were 2436 με and 437.03 kN. (3) Increasing the load capacity of the yield conditions (Py) of the pile cap STM method and conventional method on the plan load (Pn) were 32.2% and 9.3%.Keywords: pile cap, four piles, Strut and Tie Model (STM)  ABSTRAK Pile cap merupakan salah satu dari jenis struktur yang sepenuhnya merupakan daerah terganggu (Disturbed-region). Struktur tersebut mengalami regangan non-linear karena merupakan titik pertemuan pile dan kolom dengan gaya-gaya terpusat. Selain itu, terjadi perubahan geometri pada pertemuan antara kolom, pile cap, dan pile, sehingga konsep Bernoulli tidak cocok lagi pada kondisi tersebut. Pengujian pile cap terdiri dari dua kelompok benda uji dan masing-masing kelompok terdiri dari tiga buah benda uji. Kelompok pertama dirancang menggunakan metode STM (SNI 2847:2013 Lampiran A) dan kelompok kedua dirancang menggunakan metode konvensional (SNI 2847:2013 Pasal 15). Pembebanan berupa penerapan beban statik terpusat yang disalurkan melalui kolom sentris sampai struktur pile cap mengalami keruntuhan. Hasil menunjukkan bahwa: (1) Tulangan lentur yang mengalami kondisi leleh terlebih dahulu baik pada pengujian benda uji pile cap metode STM maupun pada metode konvensional adalah tulangan lentur arah X (tulangan lentur terluar). (2) Rata-rata regangan kondisi leleh dan beban pada benda uji pile cap metode STM adalah 2242 με dan 528,97 kN, sedangkan pada metode konvensional adalah 2436 με dan 437,03 kN . (3) Peningkatan kapasitas beban kondisi leleh (Py) pada benda uji pile cap metode STM dan metode konvensional terhadap beban rencana (Pn) adalah 32,2 % dan 9,3 %. Kata kunci: pile cap, empat tiang, Strut-and-Tie Model (STM)
EKSPERIMEN PADA STRUKTUR PILE CAP TIGA TIANG DENGAN METODE STRUT AND TIE MODEL Maulana Agung Sedayu; Djoko Sulistyo; Akhmad Aminullah
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1049.207 KB) | DOI: 10.21831/inersia.v15i2.28619

Abstract

 ABSTRACTIn general, the design of the pile cap structure still uses conventional method assuming all regions experience linear strain. However, in reality the strain distribution in the cross section of the structure is not always linear so that a rational analysis method is needed with the assumption that is close to the actual condition using the strut and tie model method. This study aims to determine the behavior of crack pattern in the pile cap designed using the strut and tie model method (SNI 2847:2013 Appendix A) compared to conventional methods (SNI 2847:2013 Article 15). The specimen is the pile cap with three-piles and concentrated load, each of which has three methods. Loading is a static load that is channeled through a column located centric towards the structure of the pile cap. The results show that: the entire test object based on the two methods have flexural crack pattern. The average load capacity of the first crack (Pcr) on the specimen was designed using the strut and tie model and the conventional method were 239.0 kN and 193.7 kN. The average of crack width on the specimen using the strut and tie model and the conventional method were 0.68 mm and 3.88 mm.Keywords: crack pattern, pile cap, three-piles, strut and tie model ABSTRAK Pada umumnya perancangan struktur pile cap masih menggunakan metode konvensional dengan asumsi semua daerah mengalami regangan linier. Akan tetapi pada kenyataannya distribusi regangan pada penampang struktur tidak selalu linier sehingga diperlukan suatu metode analisis yang rasional dengan asumsi yang mendekati kondisi sebenarnya yaitu menggunakan metode strut and tie model. Penelitian ini bertujuan untuk mengetahui perilaku pola retak pada pile cap yang dirancang dengan metode strut and tie model (SNI 2847:2013 Lampiran A) dibandingkan dengan metode konvensional (SNI 2847:2013 Pasal 15). Pada setiap metode terdiri dari tiga buah benda uji berupa pile cap tiga tiang dengan beban sentris. Pembebanan berupa beban statis yang disalurkan melalui kolom yang terletak sentris terhadap struktur pile cap. Hasil pengujian menunjukkan bahwa keseluruhan benda uji berdasarkan kedua metode mempunyai pola retak lentur (flexural crack). Untuk rata-rata kapasitas beban saat retak pertama (Pcr) pada benda uji yang dirancang menggunakan metode strut and tie model dan metode konvensional adalah sebesar 239,0 kN dan 193,7 kN. Kemudian rata-rata lebar retak pada benda uji menggunakan metode strut and tie model dan metode konvensional adalah sebesar 0,68 mm dan 3,88 mm. Kata kunci: pola retak, pile cap, tiga tiang, strut and tie model
PENGARUH BIAYA PRASARANA, SARANA, UTILITAS DAN OVERHEAD TERHADAP BIAYA PRODUKSI UNIT BANGUNAN PADA PERUMAHAN MEWAH DI YOGYAKARTA Vivid Lucha Deanggi; Arief Setiawan Budi Nugroho; Fauzie Siswanto
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (686.468 KB) | DOI: 10.21831/inersia.v15i2.28626

Abstract

 ABSTRACTMany factors  influence developers to determine proce of a house unit of housing. There are some additional costs must be considered for accomplishing projects which not directly related to the cost of a house units. These costs are needed to provide basic and supporting facilities, utilities and some other project overheads are then borne to prospective customers. This study observed the influence of those costs to the cost of building units of luxury housing in Yogyakarta. The survey was conducted to find the cost components from two luxury housing projects. The data was obtained through interviewing field supervisors and heads of engineering which consisted of the costs for developing public and residental facilities, expensing projects overhead, land acquition and house construction. The results showsed that in average, cost of facilities, infrastructure, utilities and project overhead of both housing affect about 29,9% of the total, it also shows that land acquittion for road construction became the highest influenced cost. Keywords: basic facilities, effect,overhead, supporting facilities, utilities  ABSTRAK Banyak faktor mempengaruhi pengembang perumahan dalam menentukan harga tiap unit rumah. Selain biaya dasar unit rumah, terdapat beberapa biaya tambahan yang tidak langsung berhubungan dengan biaya pembangunan unit rumah seperti, biaya bahan, alat dan tenaga kerja namun harus dipersiapkan untuk mendukung pelaksanaannya. Biaya-biaya tersebut seperti biaya untuk pemenuhan keberadaan prasarana, sarana, utilitas dan overhead yang pada umumnya kemudian dibebankan kepada pelanggan yang membeli setiap unit rumah. Studi ini membahas pengaruh keberadaan biaya-biaya tambahan tersebut terhadap biaya produksi unit bangunan pada perumahan mewah di Yogyakarta. Survei dilakukan pada dua perumahan mewah di Yogyakarta. data diperoleh melalui wawancara dengan supervisor lapangan dan kepala teknik yang berupa biaya pengembangan fasilitas umum dan fasilitas sosial perumahan, overhead, pengadaan lahan dan biaya bangunan. Hasil penelitian menunjukkan bahwa secara rata-rata pembiayaan fasilitas, infrastruktur, utilitas dan overhead terhadap biaya unit bangunan pada kedua perumahan berpengaruh sebesar 29,9% dari total biaya yang diperlukan, dimana biaya pengadaan tanah untuk prasarana jalan menyumbangkan kontribusi terbesar dalam pembiaayaan tersebut. Kata kunci: biaya, pengaruh, perumahan, overhead
EVALUASI KETAHANAN GEMPA RUMAH SEDERHANA DI KELURAHAN RUM, KOTA TIDORE KEPULAUAN Ahmad Aldo; Galeh Nur Indriatno Pratama
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (480.287 KB) | DOI: 10.21831/inersia.v15i2.28565

Abstract

ABSTRACTThe aim of this study was to determine the level of resilience/ feasibility of simple houses on Rum Village against earhquakes. Simple house is restricted to building area of ≤ 70 m2. In this study, the simple houses that will be observe are grouped into four levels of feasibility consisting of: (1) very suitable; (2) quite suitable; (3) less suitable; and (4) unsuitable. The research was carried out on 28 July – 04 August 2019. The research was carried out through a survey of 35 simple houses in Rum Village, Tidore Kepulauan City, North Maluku Province. The sample of houses was chosen randomly and evenly based on the level of density of RT 1 – RT 13, with the exception of RT 10. From the results, it was found that 6 houses (17%) were categorized as very suitable for earthquake. Furthermore, 5 houses (12%) were classified as suitable, 21 houses (60%) were classified as less suitable, and 3 houses (8%) were classified as unsuitable. After the interview with the foreman, the number of houses that are less suitable for earthquakes is caused by there is no reinforcement concrete beam sloof as a lower structure. Lack of budget is a major factor that make sloof is not build on the simple houses. Therefore, recommendations were made to the relevant government in the Tidore Kepulauan City to provide housing construction subsidies in the form of budget/ building materials. In addition, the government can innovate alternative building materials as a substitute for reinforcement concrete which is cheaper but still strong enough.Keywords: earthquakres, houses, concrete ABSTRAKTujuan penelitian ini adalah untuk mengetahui tingkat ketahanan/ kelayakan rumah tipe sederhana di Kelurahan Rum terhadap gempa bumi. Rumah sederhana dibatasi untuk tempat inggal dengan luas bangunan ≤ 70 m2. Dalam penelitian ini, rumah sederhana yang akan ditinjau dikelompokkan menjadi empat tingkatan kelayakan yang terdiri atas: 1) sangat cocok; 2) cukup cocok; 3) kurang cocok; dan 4) tidak cocok. Kegiatan dilaksanakan pada tanggal 28 juli – 04 agustus 2019. Penelitian dilakukan melalui survey terhadap 35 rumah sederhana di Kelurahan Rum, Kota Tidore Kepulauan, Provinsi Maluku Utara. Sampel rumah dipilih secara acak dan merata berdasarkan tingkat kepadatan dari RT 1 –RT 13, terkecuali RT 10. Dari hasil analisis survey, diketahui bahwa 6 rumah (17 %) masuk kategori sangat cocok ketahanannya terhadap gempa bumi. Selanjutnya, 5 rumah (12 %) tergolong cukup cocok, 21 rumah (60%) tergolong kurang cocok, dan 3 rumah (8 %) tergolong tidak cocok. Setelah dilakukan wawancara dengan mandor setempat, banyaknya rumah yang kurang cocok terhadap gempa bumi disebabkan oleh tidak terbangunnya beton sloof sebagai struktur bangunan bagian bawah. Kurangnya anggaran menjadi faktor penyebab utama tidak terbangunnya sloof bagi rumah tinggal sederhana. Oleh karena itu, disusun rekomendasi kepada pemerintah terkait di Kota Tidore Kepulauan untuk memberkan subsidi pembangunan rumah berupa anggaran/ bahan bangunan. Selain itu, pemerintah dapat melakukan inovasi bahan bangunan alternatif sebagai pengganti beton bertulang yang lebih murah namun cukup kuat.Kata kunci: gempa bumi, rumah, beton
KARAKTERISTIK MARSHALL QUOTIENT PADA HOT MIX ASPHALT MENGGUNAKAN AGREGAT ALAM SUNGAI OPAK Maris Setyo Nugroho
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (290.025 KB) | DOI: 10.21831/inersia.v15i2.28627

Abstract

 ABSTRACTThe purpose of this study is to determine the Marshall Quotient (MQ) value of hot mix asphalt (HMA), which uses natural aggregates from the Opak river. In addition to the MQ value in this study also examines the value of stability and flow in concrete asphalt mixtures with asphalt content of 6.5%. The research method used was an experimental method in the JPTSP FT UNY road construction laboratory. The testing standard used refers to the Indonesian National Standard (SNI). In addition to testing Marshall values, preliminary testing is also carried out to determine the quality of the material used. Material testing includes aggregate quality testing and asphalt quality testing. Based on the test results, the stability, flow and MQ values were 1177.01 kg, 3.20 mm and 384.05 kg/mm respectively. When compared with the requirements in the RSNI 03-1737-1989, only the flow values do not meet the requirements.Keywords: hot mix asphalt (HMA), stability, flow, marshall quotient ABSTRAK Penelitian ini bertujuan untuk mengetahui nilai Marshall/Marshall Quotient (MQ)dari campuran aspal panas/hot mix asphalt (HMA), yang menggunakan agregat alami dari kali Opak. Selain nilai MQ pada penelitian ini juga mengkaji nilai stabilitas dan kelelehan (flow) pada campuran aspal beton dengan kadar aspal 6,5%. Metode penelitian yang digunakan yaitu metode eksperimental di laboratorium konstruksi jalan JPTSP FT UNY. Standar pengujian yang digunakan mengacu Standar Nasional Indonesia (SNI). Selain pengujian nilai Marshall juga dilakukan pengujian pendahuluan untuk mengetahui mutu material yang digunakan. Pengujian material yang dilakukan meliputi pengujian mutu agregat dan pengujian mutu aspal yang digunakan untuk campuran aspal beton. Bersarkan hasil pengujian diperoleh nilai stabilitas, kelelehan, dan nilai Marshall berturut-turut sebesar 1171,01 kg, 3,20 mm, dan 384,05 kg/mm. Jika dibandingkan dengan persyaratan nilai stabilitas, kelelehan, dan nilai marshal yang tercantum pada RSNI 03-1737-1989, hanya nilai kelehan saja yang tidak memenuhi persyaratan. Kata kunci: hot mix asphalt (HMA), stabilitas, kelelehan, nilai marshall
KORELASI KUAT TEKAN TERHADAP KAPASITAS GESER BALOK BETON DENGAN VARIASI PERAWATAN Elviana Elviana; Ashar Saputra; Djoko Sulistyo
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (782.603 KB) | DOI: 10.21831/inersia.v15i2.28567

Abstract

ABSTRACTThe beam material in the construction world is designed to withstand collapse due to bending, diagonal drag, and sliding. Shear behavior in design becomes a very complex problem and is not easy to predict. However, failure due to the influence of shear forces is avoided in the design world due to damage that occurs without prior precautions, so that building users do not have the opportunity to save themselves. The study of variables that determine shear forces is a contradictory debate. One of the influential variables is the compressive strength of concrete (fc’). This work examines the correlation of compressive strength to the shear capacity of concrete beams with variations in care because there is still very little literature in Indonesia that studies the relationship of the two variables. Tests carried out on beams with reinforcement and without reinforcement which have pxlxt size is 1000x200x400 mm by getting the behavior of the point load at the center of the span (three-point load). Maintenance variations are carried out by testing in wet conditions as material representation in water construction and dry conditions for ordinary buildings. After 150 days of study, it was found that the compressive strength of concrete had a higher correlation with the strength of the concrete at the time of cracking (Vcr) than the strength of ultimate concrete (Vu). Wet conditions will produce lower strength than linear conditions with linear correlation levels of both.Keywords: concrete, compressive strength, shear strength, concrete treatment ABSTRAK Material balok dalam dunia konstruksi dirancang untuk tahan terhadap keruntuhan akibat lentur, tarik diagonal, dan geser. Parilaku geser dalam perancangan menjadi permasalahan yang sangat kompleks dan tidak mudah untuk diprediksi. Namun demikian kegagalan karena pengaruh gaya geser sangat dihindari dalam dunia perancangan dikarenakan kerusakan yang terjadi tanpa didahului dengan peringatan terlebih dahulu, sehingga pengguna bangunan tidak memiliki kesempatan untuk menyelematkan diri. Pengkajian mengenai variabel yang menentukan kekuatan geser menjadi sebuah perdebatan yang kontradiktif. Salah satu variabel yang berpengaruh adalah kekuatan tekan beton (fc’). Penelitian ini mengkaji mengenai korelasi kuat tekan terhadap kapasitas geser balok beton dengan variasi perawatan dikarenakan masih sangat sedikit literatur di Indonesia yang melakukan pengkajian hubungan kedua variabel tersebut. Pengujian dilakukan pada balok dengan tulangan dan tanpa tulangan yang memiliki ukuran pxlxt adalah 1000x200x400 mm dengan mendapatkan perilaku beban titik di pusat bentang (three-point load). Variasi perawatan dilakukan dengan melakukan pengujian pada kondisi basah sebagai representasi material pada konstruksi bangunan air dan kondisi kering untuk bangunan biasa. Setelah dilakukan pengkajian selama 150 hari diperoleh hasil bahwa kuat tekan beton memiliki korelasi lebih tinggi terhadap kekuatan beton pada saat retak (Vcr) daripada kekuatan beton ultimit (Vu). Kondisi basah akan menghasilkan kekuatan yang lebih rendah dari kondisi kering yang linier dengan tingkat korelasi keduanya. Kata kunci: beton, kuat tekan, kuat geser, perawatan beton
UJI KELAYAKAN TANAH PADA PERENCANAAN SEPTIC TANK KOMUNAL DI LAHAN BERKONTUR PERMUKIMAN BANTARAN SUNGAI KOTA YOGYAKARTA Hestin Mulyandari; Adwiyah Asyifa
Inersia : Jurnal Teknik Sipil dan Arsitektur Vol 15, No 2 (2019): Desember
Publisher : Universitas Negeri Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (301.88 KB) | DOI: 10.21831/inersia.v15i2.28568

Abstract

ABSTRACTCode riverbanks are dominated by land for settlements, one of the points being the proposed establishment of rusunami, in Jetisharjo, city of Yogyakarta. Riverbanks at the location are slippery, so have many problems of structure and infrastructure. In the planning of rusunami, it is necessary to consider the location of the communal septic tank. The research use method of quantitative research. The results of soil testing are soil moisture content of 7.788%, density of 2.688, soil shear strength (Ʈ) of 0.870 kg/cm2, internal friction angle of 440, and sandy soil. The results of the shear strength testing of the land that the selected location contain subgrade, so that if it will be used as a communal septictank, it needs to be made a strong enough foundation to avoid degradation and slope failure, the construction of communal septic tanks must be made strong so that they can avoid lift by water pressure.Keywords: soil test, communal septic tank, contoured land ABSTRAKBantaran Sungai Code  didominasi lahannya untuk permukiman, salah satu titiknya menjadi usulan berdirinya rusunami, di RW 07 Kecamatan Jetisharjo, Kota Yogyakarta. Bantaran Sungai di lokasi tersebut sangat curam, sehingga dari segi struktur dan infrastruktur banyak mengalami kendala. Pada perencanaan rusunami nantinya perlu diperhitungkan titik-titik yang menjadi lokasi septic tank komunalnya. Metode penelitian yang digunakan adalah penelitian kuantitatif. Hasil pengujian tanah sebagai berikut: kadar air tanah sebesar 7, 788%, berat jenis sebesar 2,688, kuat geser tanah (Ʈ) sebesar 0,870 kg/cm2, sudut gesek internalnya  440, dan berjenis tanah pasir. Dari hasil uji gesernya kekuatan tanahnya bahwa lokasi terpilih merupakan bekas tanah urug, sehingga apabila akan dijadikan septictank komunal perlu dibuatkan fondasi yang cukup kuat untuk menghindari  penurunan dan kelongsoran tebing, maka konstruksi septic tank komunal harus dibuat kokoh sehingga dapat terhindar dari up lift oleh tekanan air.Disarankan menggunakan septic tank moderen (fabricated).Kata kunci: uji tanah, septic tank komunal, lahan berkontur

Page 1 of 1 | Total Record : 8