PENGARUH KADAR LUMPUR PADA AGREGAT HALUS DALAM MUTU BETON Purwanto, Purwanto; Arni Priastiwi, Yulita
TEKNIK Volume 33, Nomor 2, Tahun 2012
Publisher : Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (989.594 KB) | DOI: 10.14710/teknik.v33i2.4385

Abstract

Clay lumps on the aggregate levels is one of the factors that may cause disruption of the binding process andhardening of concrete. Clay lump can not blend with cement so that blocking a merger between the cement withaggregates which eventually led to the compressive strength of concrete will be reduced in the absence ofbinding to each other. SK SNI S-04-1989-F, the allowable levels of clay lump maximum of 5% to fine aggregate(sand) and maximum of 1% for coarse aggregate (split).In this study to determine the effect of the clay lump on the fine aggregate content on compressive strength ofconcrete on five (5) variations levels of the category of clean clay lump with content of 1% and 2%, medium claylump 4% and dirty sand with levels 7 % and 11%, whereas for the coarse aggregate clay lump content was0.7%.From the results of a study of 90 cylindrical specimens showed that the small amount of clay lump, the higherthe compressive strength of concrete. Concrete compressive strength test results on average with dirty clay lumpcontent was 31.30 MPa, compressive strength for the concrete medium with clay lump levels were at 33.92 MPaand compressive strength for the concrete clean of clay lump 36.68 MPa. Compared to the dirty clay lump anincrease in the levels of average compressive strength for moderate levels of 8,37% and the clean sand of17,19%. Besides affecting in compressive strength, clay lump levels also affect the weight of concrete, andconcrete density. The greater the level of clay lump, weight of concrete and concrete density will be lower.Compared to the dirty clay lump an increase in the levels of average concrete density for moderate levels of 6,54% and the clean sand of 12,59%.
TESTING OF CONCRETE PAVING BLOCKS THE BS EN 1338:2003 BRITISH AND EUROPEAN STANDARD CODE Purwanto, Purwanto; Arni Priastiwi, Yulita
TEKNIK Volume 29, Nomor 2, Tahun 2008
Publisher : Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4570.828 KB) | DOI: 10.14710/teknik.v29i2.1936

Abstract

Concrete paving blocks are the choice for road and urban road’s surfacing. Besides their ease inapplication, they also provide design freedom by coloring off the material.Of major importance is their compression strength. The Indonesian SNI categorizes strength to theirpurposes i.e., for parking areas, pedestrian walking areas and heavy industrial estates.According to the SNI 03 – 0691 -1989 and British Standard BS 6717:1986 the strength of a paving blockis determined by the maximum carrying capacity under distributed load. The blocks are placed under acompression apparatus, and the compression strength at failure is recorded.As being observed in the field paving block’s failure pattern differs as to the failure under distributedloading. The paving’s failure mode is distinguished by a bending failure plain at the smallest crosssection.The BS EN 1338 code proposes a different approach. This paper will discuss the methods being used inthe BS EN 1338 code, and evaluates the effectiveness of Indonesian standards to date.
Sustainability Beton Metode Life Cycle Assessment Studi Kasus: Limbah Beton Laboratorium Bahan dan Konstruksi Departemen Teknik Sipil Universitas Diponegoro Semarang Sapulete, Christhy Amalia; Lie, Han Ay; Priastiwi, Yulita Arni
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 24, Nomor 2, DESEMBER 2018
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (954.701 KB) | DOI: 10.14710/mkts.v24i2.18863

Abstract

Sustainability is an effort to build an infrastructure by considering the environmental impacts that occur. Concrete production as a construction material that commonly used in infrastructure development is one contributor to carbon dioxide (CO2) emissions. CO2 is produced from the calcination process in the manufacture of cement, burning of fossil fuels, and electrical energy used. More specifically by reviewing the calcination process on cement making, it has evaluated the consumption of cement in concrete production. The Life Cycle Assessment (LCA) is an environmental impact evaluation in terms of the life cycle of a product, wherein this paper, using the cradle-to-cradle scope, LCA is used as a method to evaluate cement consumption in concrete production to concrete waste management by taking concrete waste at Construction Laboratory and Materials Diponegoro University, Semarang for the case study. The results of the evaluation stated that the use of geopolymer concrete with fly ash as a substitute for cement could reduce up to 80% CO2 emissions with concrete strength 75% larger than conventional concrete. And for the concrete waste management, Construction Laboratory and Materials Diponegoro University reused concrete cylinder waste as a substitute material to build the retaining wall.
Pengaruh Substitusi Tanah Putih pada Mortar Geopolimer Berbahan Dasar Fly Ash dengan Aktifator Natrium Hidroksida Priastiwi, Yulita Arni; Hidayat, Arif; Daryanto, Dwi; Badru, Zidny Salamsyah
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 26, Nomor 1, JULI 2020
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (596.877 KB) | DOI: 10.14710/mkts.v26i1.24715

Abstract

The presence of white soil in a geopolymer mortar affects the physical and mechanical properties of the mortar itself, especially in compressive strength, density and modulus of elasticity produced. Geopolymer mortar composed of fly ash, sand, water, and NaOH which acts as an alkaline activator compared to mortar from the same material, but white soil from Kupang is added as a substitution of fly ash. Specimens are made in six variations. Geopolymer mortar composers using a ratio of 1 binder: 3 sand with w/b of 0.5. Binder composed of fly ash with white soil substitution of 0; 5; 10; 15; 20 and 30% by weight of fly ash. An activator NaOH 8M solution was added to the mixture. Both white soil and fly ash pass of sieve no. 200 with a moisture content of 0%. Mortar made measuring 5x5x5 cm. The mortar was treated by the oven of method at 60 oC for 24 hours until the mortar does not change in weight. The test results show geopolymer mortar with 15% substitution of white soil to fly ash has the highest compressive strength, density and modulus of elasticity among other variations. In all mortar variations, compressive strength at 14 days has reached 75% of strength at 28 days.
Korelasi Nilai Tegangan Dan Sudut Trajektori Terhadap Rasio Dimensi Pada Balok Tinggi Adi Putra, Kukuh Cahya; Priastiwi, Yulita Arni; Sukamta, Sukamta
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 27, Nomor 1, JULI 2021
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (658.944 KB) | DOI: 10.14710/mkts.v27i1.30591

Abstract

Menurut SNI 2847-2019 pengertian balok tinggi adalah komponen struktur yang dibebani satu sisi dan ditopang pada muka yang berlawanan sedemikian hingga komponen tekan sepert  strat dapat terbentuk diantara beban dan tumpuan. Dijabarkan pula rasio bentang bersih balok dibandingkan tinggi balok harus memenuhi persyaratan (l/h) < 4. Tujuan dari penelitian ini adalah mencari nilai korelasi tegangan dan sudut trajektori terhadap rasio l/h balok dengan bentang 4 meter ketika diberikan beban terpusat, P = 2000 kN. Dalam proses analisanya menggunakan software SAP v.14 untuk mencari nilai tegangan dan sudut trajektori berbagai variasi l/h.  Hasil yang didapat dari penelitian ini yaitu : (1) Rasio l/h balok tinggi mempengaruhi besarnya tegangan dan sudut trajektori, dimana semakin kecil rasio l/h balok semakin kecil pula tegangan dan semakin besar sudut trajektori yang dihasilkan, (2) Variasi lebar balok mempengaruhi besarnya tegangan tetapi tidak dengan sudut trajektorinya. Semakin bertambah lebar balok, semakin kecil tegangan tarik dan tekan maksimumnya. Semakin bertambah lebar balok ternyata tidak berpengaruh signifikan terhadap sudut trajektori yang dihasilkan.
Pemanfaatan Batu Pumice Dalam Mengurangi Penurunan Performa Beton Pasca Kebakaran Muhammad Akhis Thoyfurrohman; Bagas Indra Cahyo; Erika Yulianti; Nuroji Nuroji; Yulita Arni Priastiwi
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.569

Abstract

Abstrak Beton yang mengalami kebakaran pada suhu 400˚C akan mengalami degradasi kekuatan hingga kuat tekan sisa 58,40% Hal ini akan mempengaruhi kualitas/kekuatan struktur beton tersebut dan akan menyebabkan beton menjadi getas, dan memungkinkan struktur mengalami kegagalan. Diperlukan upaya proteksi pasif kebakaran dengan menggunakan material yang memiliki ketahanan terhadap api. Salah satu material yang memiliki ketahanan terhadap api yang baik adalah batu pumice. Penelitian ini bertujuan untuk mengetahui nilai kuat tekan dan laju penurunan kekuatan beton pumice yang menggunakan Pasir Muntilan sebagai agregat halus akibat perubahan suhu pembakaran pada 27°C, 300°C, dan 600°C. Penelitian menggunakan 45 buah benda uji silinder beton berukuran diameter 15 cm dan tinggi 30 cm. Dengan variasi penggantian batu pumice 0% , 25%, 50%, 75% dan 100% dari volume agregat kasar dan Faktor Air Semen (FAS) sebesar 0,5. Pengujian kuat tekan dengan alat compression saat umur 28 hari. Hasil penelitian ini menunjukkan bahwa suhu pembakaran mempengaruhi kuat tekan beton pumice dengan pasir Muntilan pada semua komposisi proporsi. Semakin tinggi suhu pembakaran maka semakin besar penurunan yang terjadi. Besaran penurunan kuat tekan akibat kenaikan suhu pembakaran berkisar antara 0,16% hingga 55,38% lebih lambat dibandingkan dengan beton tanpa menggunakan batu pumice Kata kunci: Beton, Batu Pumice, Performa Beton  Abstract Concrete that has been burned at 400° C will experience degradation to a residual compressive strength of 58.40%. This will affect the strength of the concrete structure and will cause the concrete to become brittle, thus allowing the structure to fail. Then it will require passive fire protection by using materials that have some resistance to the fire. One material that has the potential to create fire resistance is pumice stone. The purpose of this study was to determine the value of compressive strength and the rate of reduction in compressive strength of Muntilan sand pumice concrete due to the changes in combustion temperature of 27˚C,300˚C, and 600˚C. In this study, used a 45 pieces concrete cylinder with a diameter of 15 cm and a height of 30 cm. with variations of pumice stone proportion of 0%, 25%, 50%,75% and 100% of the volume of coarse aggregate with a water cement ratio of 0.5. Compressive strength test with a compression device at the age of 28 days. The results of this study indicate that the combustion temperature affects the compressive strength of pumice concrete. The higher the combustion temperature, the higher the strength reduction that occurs. The amount of reduction in compressive strength due to an increase in combustion temperature ranged from 0.16% to 55.38% of the control specimens. Keywords: Pumice, Compressive Strength, Temperature
STRUT AND TIE MODEL STRUKTUR BALOK TINGGI BERLUBANG Kamila Shaomi Nazila; Yulita Arni Priastiwi; Sukamta Sukamta
TERAS JURNAL Vol 11, No 1 (2021): Maret 2021
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v11i1.362

Abstract

Abstrak Mendesain suatu bangunan tingkat tinggi dengan tidak menggunakan plafon dibutuhkan perencanaan yang ekonomis tanpa mengurangi kekuatan dan keindahan dari bangunan tersebut. Balok tinggi berlubang dengan material struktur beton digunakan untuk menghindari terjadinya sistem utilitas pada suatu bangunan tingkat tinggi dengan tidak menggunakan plafon. Balok tinggi berlubang ini ditinjau menggunakan metode Strut and Tie Model (STM). Untuk mengatasi permasalahan yang ada biasanya para perencana merancang daerah D (Disturbed Region) dengan menggunakan konsep pendetailan berdasarkan aliran gaya, sehingga metode strut and tie merupakan pendekatan yang sesuai untuk menganalisis struktur beton di daerah D. Program analisa struktur digunakan untuk melakukan analisis gaya dalam berupa momen dan geser pada struktur beton balok tinggi berlubang. Hasil analisis yang diperoleh pada struktur beton balok tinggi berlubang yaitu bahwa semakin dekat lubang balok dengan tumpuan maka nilai tulangan lentur akan lebih tinggi dan semakin bertambah pula tulangan gesernya. Kata kunci: Balok Tinggi Berlubang, Daerah D, Metode Strut and Tie  Abstract Designing a high rise building without using a ceilings requires an economical plan without reducing the strength and the art of the building. The deep beam with holes, which have the structure of concrete materials is need to be used to avoid the utility system in a high rise building without ceilings. This deep beam with holes is reviewed by the Strut and Tie Model (STM) method. To solve the existing problems, planners usually design the D region (Disturbed Region) use the concept of detail based on the flow of force. So the strut and tie method is an appropriate method to analyze the structure of concrete at D region (Disturbed Region). The program of analysis structure is used to analyze the internal forces, which are Moment and Shear, in the deep beams with holes' structure. The result of the analysis in the  deep beam concrete with holes is the more position of the hole is close to its pedestal, the value of the Flexural reinforcement will be more increase, and teh Shear reinforcement will be higher too. Keywords: Deep Beam Hollow, D Region, Strut and Tie Model
ANALISIS ALTERNATIF DALAM MERANCANG BALOK TINGGI MENGGUNAKAN STRUT AND TIE MODEL Nisa Luthfiana; Yulita Arni Priastiwi
TERAS JURNAL Vol 11, No 1 (2021): Maret 2021
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v11i1.393

Abstract

Abstrak Perencanaan struktur beton biasanya dilakukan dengan berdasarkan asumsi dari Bernoulli dan Navier untuk menganalisis penampang akibat momen lentur. Distribusi regangan dianggap linier dan ini dianggap masih berlaku meskipun penampang telah retak. Balok tinggi merupakan salah satu contoh kasus pada suatu elemen struktur yang dapat mengakibatkan terjadinya distribusi tegangan non linier, sehingga asumsi diatas tidak berlaku. Balok dikatakan balok tinggi apabila rasio bentang terhadap tingginya lebih kecil dari lima. Salah satu alternatif pendekatan untuk mengatasi elemen struktur seperti balok tinggi adalah menggunakan pendekatan Strut and Tie Model, yaitu dengan membagi struktur dalam daerah B (Bernoulli) dan D (Disturb) dan menggambarkan alur gaya (load path) sebagai transfer gaya yang terjadi pada struktur beton bertulang pada kondisi retak akibat pembebanannya. Parameter–parameter dari Strut and Tie Model yaitu batang tekan (strut), batang tarik (tie) dan titik nodal (nodal zone) sebagai daerah pertemuan. Tujuan dari tulisan ini adalah untuk menganalisis alternatif perencanaan/desain tulangan struktur balok tinggi beton bertulang diatas dua tumpuan sederhana akibat beban merata yang dikonversi menggunakan beban terpusat 2 titik pembebanan.Metode yang digunakan adalah Strut and Tie Model yang akan menghasilkan luas tulangan longitudinal yang lebih kecil dengan selisih 25%, di mana dengan luas tulangan yang lebih kecil dari segi kekuatan masih memenuhi syarat. Hal ini menunjukkan bahwa perhitungan perencanaan balok tinggi tanpa bearing plate dengan menggunakan metode Strut and Tie Model pun dapat lebih optimum/efisien. Kata kunci: Prinsip Bernoulli, Strut and Tie Model, D – Region, B – Region   Abstract Concrete structure planning is usually carried out based on the assumptions of Bernoulli and Navier to analyze the section due to bending moments. The strain distribution is considered linear and it is considered still valid even after the section has cracked.  The deep beam is one example of a structural element that can result in a non–linear stress distribution, so the above assumption does not apply. A beam is said to be a deep beam if the span to height ratio is less than five. One alternative approach to dealing with structural elements such as deep beams is to use the Strut and Tie Model approach, namely by dividing the structure into areas B (Bernoulli) and D (Disturb) and describing the load path as a force transfer that occurs in the concrete structure. Reinforced in cracked conditions due to loading. The parameters of the Strut and Tie Model are the strut, tie, and nodal zone as the meeting area. The purpose of this paper is to analyze the alternative planning/design of reinforced concrete beams structure on two simple supports due to evenlydistributed loads that are converted using the two-point load centered load. The method used is the Strut and Tie Model which will produce a smaller area of longitudinal reinforcement with a difference of 25%, where the area of reinforcement is smaller in terms of strength still meets the requirements. This shows that the calculation of deep beam planning without bearing plate using the strut and tie model method can be more optimal/efficient. Keywords: Bernoulli’s Principle, Strut and Tie Model, D - Region, B - Region
PENGARUH MUTU MORTAR DAN DIMENSI INKLUSI TERHADAP KUAT TEKAN MORTAR-INKLUSI Purwanto Purwanto; Himawan Indarto; Yulita Arni Pratiwi; Nauval Rabbani; Mona Dwi Anggraeni
Jurnal Ilmiah Teknik Sipil Jurnal Ilmiah Teknik Sipil, Vol. 22, No. 1, Januari 2018
Publisher : Department of Civil Engineering, Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (581.967 KB) | DOI: 10.24843/JITS.2018.v22.i01.p03

Abstract

Kuat tekan beton sangat dipengaruhi oleh material penyusunnya, perilaku saat pencampurannya, perawatannya, dan kekuatan hubungan lekatan yang terjadi antara permukaan agregat kasar dengan mortar atau yang disebut Interfacial Iransition Zone (ITZ). Penelitian menunjukkan bahwa rasio kuat tekan inklusi agregat terhadap kuat tekan mortar sangat signifikan mempengaruhi perilaku ITZ dan keseluruhan benda uji. Namun sejauh ini penelitian difokuskan pada inklusi batuan, sedangkan perilaku ITZ dengan inklusi baja belum banyak dilakukan. Baja mempunyai sifat relatif lebih homogen dan stabil, tak memiliki retak mikro serta tak menyerap air, sehingga pengaruh mutu mortar pada ITZ akan tampak lebih jelas. Untuk mempelajari perilaku inklusi baja pada benda uji, maka dilakukan studi menggunakan beberapa varian mutu mortar dengan kuat tekan 20, 40, dan 60 MPa. Ukuran benda uji adalah 150×150×50 mm dengan inklusi silinderis besi baja berdiameter 25 mm dan 32 mm. Silinder baja ditempatkan tepat pada pusat berat mortar. Disediakan pula benda uji kontrol berupa mortar tanpa inklusi dengan ukuran 150×150×50 mm untuk dapat membandingkan perilaku pengaruh dari variasi mutu dan variasi diameter inklusi silinder baja. Benda uji diuji dengan pembebanan satu arah (uniaksial) menggunakan Universal Testing Machine (UTM) dan Linear Vertical Displacement Transducer (LVDT) untuk mengetahui perilaku perubahan bentuk sebagai fungsi beban. Hasil analisa menunjukkan bahwa semakin besar diameter inklusi semakin rendah pula kuat tekan yang dihasilkan serta terjadinya pola retak di area inklusi yang merupakan daerah ITZ. Kata kunci: inklusi baja, ITZ, perilaku kuat tekan, pola retak
STUDI KELAYAKAN PEMANFAATAN CAMPURAN FLY ASH DAN TANAH PUTIH SEBAGAI SEMEN ALTERNATIF Samuel Parluhutan; Gilbert Fernando; Purwanto Purwanto; Yulita arni priastiwi
Jurnal Karya Teknik Sipil Volume 7, Nomor 2, Tahun 2018
Publisher : Departemen Teknik Sipil, Fakultas Teknik Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKMortar merupakan campuran semen, pasir, dan air dengan proporsi tertentu. Pada umumnya bahan ikat campuran yang digunakan adalah semen. Unsur utama pembentuk semen itu sendiri adalah silika, alumina, dan kalsium. Kandungan silika dan alumina pada semen dapat pula diperoleh dari fly ash sedangkan kandungan kalsium dapat diperoleh dari tanah putih. Dalam penelitian ini akan dibuat mortar yang menggunakan campuran fly ash, tanah putih, dan pasir yang akan diteliti mengenai kuat tekan mortar tersebut. Variasi perbandingan fly ash dan tanah putih dengan persentase masing - masing sebesar 0%-100%, 25%-75%, 50%-50%, 75%-25%, dan 100%-0% dalam campuran mortar. Bentuk benda uji yang digunakan berbentuk kubus berukuran 5 cm x 5 cm x 5 cm. Mortar dibuat dengan metode adukan manual. Hasil penelitian menunjukkan adanya pengaruh persentase tanah putih dan fly ash terhadap kuat tekan mortar. Kuat tekan tertinggi pada umur 28 hari ditunjukkan oleh varian mortar dengan persentase fly ash dan tanah putih 50%-50%, yaitu sebesar 2,218 kg/cm2. Nilai kuat tekan mortar yang menggunakan fly ash dan tanah putih tersebut masih sangat rendah, sehingga campuran fly ash dan tanah putih tidak dapat digunakan sebagai pengganti semen bahan konstruksi.