Claim Missing Document
Check
Articles

Found 25 Documents
Search

Ubiquitous Sensor Networks: Efisiensi Sistem Kontrol Cairan Infus Pasien Rawat Inap RAHMADYA, BUDI; SISKA, MIRA; AKBAR, FAJRIL
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 5, No 2 (2017): ELKOMIKA
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v5i2.232

Abstract

ABSTRAKPenelitian ini membahas tentang sistem kontrol cairan infus pada pasien dengan memanfaatkan teknologi sensor networks dan mikrokontroler arduino uno.  Sensor yang digunakan adalah sensor Ultrasonik HC-SR04 yang difungsikan untuk mendeteksi sisa cairan infus. Data yang terbaca oleh sensor dikirimkan menggunakan jaringan nirkabel/wireless dari Transmitter (Tx) di ruang pasien ke Receiver (Rx) di ruang perawat dengan menggunakan modul wireless Xbee S2. Efisiensi dari sistem kontrol yang dibuat yaitu ketika sensor mendeteksi cairan infus mendekati batas habis cairan yang telah ditentukan maka motor yang berada pada selang infus akan berfungsi untuk menutup aliran cairan infus pada selang. Dari simulasi yang dilakukan, didapatkan hasil presentasi error ketinggian cairan infus sebesar 1.96% dan presentasi error volume cairan sebesar 2.16%. Performa dari modul wireless Xbee S2 juga di ujicoba dengan mengirimkan data dari Xbee end device ke Xbee coordinator dalam penelitian ini. Kata kunci: Infus, Sensor Networks, Sensor Ultrasonik HC-SR04, Xbee S2 dan Mikrokontroler Arduino Uno.ABSTRACTThis research discusses about intravenous fluids Control System on Patients, utilizing sensor network technology and Arduino Uno microcontroller. We used  HC-SR04 Ultrasonic sensors to detect the review time intravenous fluids. The sensors data is readable by transmitted using wireless network/wireless from Transmitter (Tx) in Patients Into Space Receiver (Rx) at nurse room with using XBee wireless device S2. The efficiency of the control system were made, namely when the sensor detects the approaching limits of intravenous fluids discharged liquid that has been determined then the motor that was on the infus line will serve to close the infusion fluid flow in the line. In our simulations we found, the findings obtained Presentation intravenous fluids altitude error is 1.96% and presentations volume Liquid error is 2.16%. The performance of network devices XBee S2 have been tried, wireless data from the XBee end devices coordinator in this research. Keywords: Infusion, Sensor Networks, HC-SR04 Ultrasonic Sensor, XBee S2 And Microcontroller Arduino Uno.  
TEKNIK KOMUNIKASI DATA PADA AD HOC NETWORK COMMUNICATION Rahmadya, Budi
Jurnal Pendidikan Teknologi dan Kejuruan Vol 11, No 2 (2014): Edisi Juli 2014
Publisher : Universitas Pendidikan Ganesha

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (373.277 KB) | DOI: 10.23887/jptk-undiksha.v11i2.4085

Abstract

Ad Hoc Network Communication is mobile networks communications and have a high mobility for each of its nodes. This type of network communications is a temporary networkwith utilizing a WiFi network or Bluethoot as a medium of communications. In the entirenetwork, node moves with a speed varying and unpredictable direction. Packets data delivery from the source node to destination node by using an ad hoc network requires its owntechniques. In this research discussed the existing data communication technique inVehicular Ad Hoc Network (VANETs) Communications with attention: Broadcasting Time, Routing Protocol, Message Dissemination, Delay Tolerant Network Dissemination and / DTN.These techniques can increase the delivery ratio / sending data packets to the destination as well as a smaller delay time. In order to maintain the integrity of the data packets received bythe destination node, the authors have proposed a method of duplicate messages in thisresearch.
Smart Home: Controlling and Monitoring Households Appliances using GSM Network Budi Rahmadya; Fahrul Ghazi; Derisma Derisma
Computer Engineering and Applications Journal Vol 5 No 2 (2016)
Publisher : Universitas Sriwijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (588.922 KB) | DOI: 10.18495/comengapp.v5i2.171

Abstract

This study discussed about using the smart home automation systems for household appliances such as lights and fans, by utilizing the GSM network as a communication medium to control and monitor the household appliances. In this study, the simulations were performed by the two following modes 1). Self-automated and 2). Manually-automated. In controlling the lamp, the light intensity that values less than 280 lux will give response of turned ON the lamp, while if the value of light intensity is more than 280 lux, it will give a response of turned OFF the lamp. To control the fan, a room temperature value of more than or equal to 30 ° C will turn ON the fan, while the room temperature value which is less than 30 ° C will turn OFF the fan. Simulations were performed by placing the devices in the room and operating it for three days. The test and simulation results were recorded in the form of log files or history files. The self-automated operations mode controlled the system using a sensor (Light Dependent Resistor and LM35 Sensor) unit to detect the environmental condition and take actions according to detected environmental condition. In the manually-automated operation mode, user could control the household appliances according to the user’s intention. The light intensity values obtained in the morning were equal to 280 lux, so it will turn off the lights. The room temperature obtained was in the range of 28oC - 33oC; the fan will turn on if the temperature value is equal to or more than 30oC.
EFISIENSI SETUP ARSITEKTUR JARINGAN KOMPUTER MENGGUNAKAN SISCO PACKET TRACER Budi Rahmadya
Jurnal Teknoif - ISSN 2338-2724 Vol 4, No 1 (2016): TEKNOIF April 2016
Publisher : ITP Press - Institut Teknologi Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1709.687 KB) | DOI: 10.21063/jtif.2016.V4.1.

Abstract

Faculty of Information Technology (FTI), Andalas University continues to develop themselves and improve infrastructure. It aims to provide better services for students, lectures and employees. In this study has simulated computer network architecture using CISCO Packet Tracer 5.3. This simulation aims to facilitate elements of the leadership make decisions regarding network architectures will be implemented. Simulations carried out by providing three components 1). Computer Server, 2). Local Area Network (LAN) and 3). Wireless network connections. Simulation is designed for multi-storey buildings of 2 (two) with a wireless LAN network connections and several rooms. This simulation implemented DHCP and Static IP.
Ubiquitous Sensor Networks: Efisiensi Sistem Kontrol Cairan Infus Pasien Rawat Inap BUDI RAHMADYA; MIRA SISKA; FAJRIL AKBAR
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 5, No 2 (2017): ELKOMIKA
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v5i2.232

Abstract

ABSTRAKPenelitian ini membahas tentang sistem kontrol cairan infus pada pasien dengan memanfaatkan teknologi sensor networks dan mikrokontroler arduino uno.  Sensor yang digunakan adalah sensor Ultrasonik HC-SR04 yang difungsikan untuk mendeteksi sisa cairan infus. Data yang terbaca oleh sensor dikirimkan menggunakan jaringan nirkabel/wireless dari Transmitter (Tx) di ruang pasien ke Receiver (Rx) di ruang perawat dengan menggunakan modul wireless Xbee S2. Efisiensi dari sistem kontrol yang dibuat yaitu ketika sensor mendeteksi cairan infus mendekati batas habis cairan yang telah ditentukan maka motor yang berada pada selang infus akan berfungsi untuk menutup aliran cairan infus pada selang. Dari simulasi yang dilakukan, didapatkan hasil presentasi error ketinggian cairan infus sebesar 1.96% dan presentasi error volume cairan sebesar 2.16%. Performa dari modul wireless Xbee S2 juga di ujicoba dengan mengirimkan data dari Xbee end device ke Xbee coordinator dalam penelitian ini. Kata kunci: Infus, Sensor Networks, Sensor Ultrasonik HC-SR04, Xbee S2 dan Mikrokontroler Arduino Uno.ABSTRACTThis research discusses about intravenous fluids Control System on Patients, utilizing sensor network technology and Arduino Uno microcontroller. We used  HC-SR04 Ultrasonic sensors to detect the review time intravenous fluids. The sensors data is readable by transmitted using wireless network/wireless from Transmitter (Tx) in Patients Into Space Receiver (Rx) at nurse room with using XBee wireless device S2. The efficiency of the control system were made, namely when the sensor detects the approaching limits of intravenous fluids discharged liquid that has been determined then the motor that was on the infus line will serve to close the infusion fluid flow in the line. In our simulations we found, the findings obtained Presentation intravenous fluids altitude error is 1.96% and presentations volume Liquid error is 2.16%. The performance of network devices XBee S2 have been tried, wireless data from the XBee end devices coordinator in this research. Keywords: Infusion, Sensor Networks, HC-SR04 Ultrasonic Sensor, XBee S2 And Microcontroller Arduino Uno.  
TEKNIK KOMUNIKASI DATA PADA AD HOC NETWORK COMMUNICATION Budi Rahmadya
Jurnal Pendidikan Teknologi dan Kejuruan Vol. 11 No. 2 (2014): Edisi Juli 2014
Publisher : Universitas Pendidikan Ganesha

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (373.277 KB) | DOI: 10.23887/jptk-undiksha.v11i2.4085

Abstract

Ad Hoc Network Communication is mobile networks communications and have a high mobility for each of its nodes. This type of network communications is a temporary networkwith utilizing a WiFi network or Bluethoot as a medium of communications. In the entirenetwork, node moves with a speed varying and unpredictable direction. Packets data delivery from the source node to destination node by using an ad hoc network requires its owntechniques. In this research discussed the existing data communication technique inVehicular Ad Hoc Network (VANETs) Communications with attention: Broadcasting Time, Routing Protocol, Message Dissemination, Delay Tolerant Network Dissemination and / DTN.These techniques can increase the delivery ratio / sending data packets to the destination as well as a smaller delay time. In order to maintain the integrity of the data packets received bythe destination node, the authors have proposed a method of duplicate messages in thisresearch.
SISTEM DETEKSI PENDERITA ARITMANIA BERDASARKAN JUMLAH DETAK JANTUNG BERBASIS SMARTPHONE Erma Gustini; Budi Rahmadya; Fajril Akbar
Prosiding Semnastek PROSIDING SEMNASTEK 2017
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Aritmia adalah gangguan irama jantung. Aritmia terjadi akibat irama jantung lambat, cepat dan tidak teratur. Untuk mendeteksi detak jantung penderita aritmia dapat di lakukan dengan mengunakan pulse sensor yang dipasang di ujung jari. Tujuan dari penelitian ini adalah untuk mendeteksi detak jantung melalui sinyal photoplethysmograph (PPG). Photoplethysmograph yang digunakan untuk monitoring  detak jantung dengan melihat perubahan volume darah dalam pembuluh darah. Pengujian detak jantung dari pulse sensor diolah di ADC di dalam mikrokontroler, kemudian data detak jantung dikirim melalui media bluethoot ke smartphone. Dalam simulasi alat dilakukan pengambilan sampel data detak jantung  pada manusia 1). normal dan 2). Penderita arimia. Dapat dilakukan  pada orang normal  dan penderita aritmia yang  berasal  dari 1 orang dewasa dan 1 orang tua dengan pengambilan sampel data sebanyak 3 kali. Untuk penderita aritmia detak jantung dapat di bagi menjadi 2 jenis yaitu bradikardi (kecil 60 bpm) dan takikardi (besar dari 100 bpm). Hasil pengujian jumlah detak jantung yang di deteksi di tampilkan di smartphone dalam bentuk sinyal. Didapatkan perbedaan detak jantung untuk penderita aritmia  adalah 44 bpm (bradikardi) dan 194 bpm (takikardi). Kata kunci: Aritmia, Pulse Sensor, Photoplethysmograph, Mikrokontroler, Bluetooth, Smartphone
IMPLEMENTASI MESIN PENETAS TELUR AYAM OTOMATIS MENGGUNAKAN METODA FUZZY LOGIC CONTROL Dhanny Jufril; Darwison Darwison; Budi Rahmadya; Derisma Derisma
Prosiding Semnastek PROSIDING SEMNASTEK 2015
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu usaha andalan bagi petani yang bergerak di bidang peternakan adalah berternak ayam pedaging dan ayam petelur. Setiap tahun data statistik mencatat kebutuhan masyarakat akan daging ayam terus mengalami peningkatan. Secara tidak langsung hal ini akan memberikan dampak positif bagi para petani khususnya peternak ayam.  Peternak ayam akan berupaya untuk meningkatkan usaha pembibitan ayam, yang bertujuan untuk mencegah terjadinya penurunan ayam pedaging dan ayam petelur. Pada penelitian ini telah di buat sebuah mesin penetas telur otomatis dengan mengimplementasikan  metode Fuzzy Logic Control. Mesin penetas telur yang dibuat memperhatikan kondisi suhu ideal dalam menetaskan telur ayam yaitu 35,3 0C – 40.5 0C, dengan kelembaban dalam mesin berkisar antara 60%-70%. Mesin ini memiliki kapasitas untuk 10 butir telur. Alat penetas telur ini merupakan modifikasi dari alat yang sudah dibuat sebelumnya yang dilengkapi dengan sensor SHT 11 sebagai pendeteksi suhu sekaligus pendeteksi kelembaban dalam ruangan inkubator dan fan sebagai sirkulasi udara. Aktuator yang digunakan untuk pemutaran rak telur adalah Motor Stepper dengan sudut 450 sebanyak 6 kali dalam waktu 24 jam.
ALAT PENGUKUR ANGKA KECUKUPAN GIZI (AKG) MANUSIA DENGAN MENGGUNAKAN MIKROKONTROLER Zakky Aulia; Budi Rahmadya; Mohammad Hafiz Hersyah
Prosiding Semnastek PROSIDING SEMNASTEK 2016
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini bertujuan untuk merancang dan membuat sebuah sistem yang dapat mengukur Angka Kecukupan Gizi (AKG) maanusia dengan menggunakan mikrokontroler. Sistem dibuat terdiri atas 5 komponen utama yaitu sensor Load Cell berfungsi untuk mengukur berat badan, sensor ultrasonik berfungsi untuk mengukur tinggi badan, Keypad berfungsi sebagai perangkat input : 1. Usia 2. Jenis kelamin 3. Jenis aktivitas. Mikrokontroler Arduino Uno berfungsi sebagai proses perhitungan AKG dan Liquid Crystal Display (LCD) berfungsi untuk menampilkan nilai AKG. Pengujian dilakukan sebanyak 10 orang objek yang terdiri dari 3 orang perempuan dan 7 orang laki-laki dengan usia antara 10-18 tahun. Seseorang harus berdiri diatas timbangan yang terpasang sensor load cell dan berdiri dibawah sensor ultrasonik yang terpasang pada tonggak untuk diukur berat dan tinggi badan. Ketika diukur berat dan tinggi badan seseorang user harus melakukan input usia, jenis kelamin dan jenis aktivitas untuk diproses oleh mikrokontroler Arduino Uno guna menghitung nilai AKG yang terdiri dari angka kecukupan energi dalam satuan kilo kalori (kkal), kecukupan protein, lemak, karbohidrat, serat dalam satuan gram (g) dan ditampilkan pada sebuah LCD. Ujicoba alat dilakukan ke 10 orang. Dan didapat kesimpulan nilai eror terkecil AKG untuk kecukupan energi yaitu 0 % dan nilai eror terbesar yaitu 6,60 %.Kata kunci : Sensor Load Cell, Sensor ultrasonik, keypad, Mikrokontroler dan Liquid Crystal Display (LCD).
PENERAPAN INVERS KINEMATIKA UNTUK PERGERAKAN KAKI ROBOT BIPED Surya Setiawan; Firdaus Firdaus; Budi Rahmadya; Derisma Derisma
Prosiding Semnastek PROSIDING SEMNASTEK 2015
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Tujuan penelitian ini adalah menerapkan metode invers kinematika terhadap gerakan kaki robot biped agar dapat berjalan. Robot biped ini menggunakan 6 buah motor servo pada kedua kakinya dan dikontrol oleh mikrokontroler arduino uno. Dengan metode invers kinematika, pergerakan kaki robot hanya ditentukan dari posisi koordinat end effector kaki pada saat berjalan sehingga tidak perlu lagi menentukan besaran sudut pada masing-masing motor servo. Ada 5 titik koordinat (x, y) kaki kanan dan kaki kiri yang digunakan robot biped untuk dapat berjalan yaitu ketika kaki ke depan di titik koordinat (0, 208) dan (205, 208), ketika kaki tegak di titik koordinat (0, 210), dan ketika kaki ke belakang di titik koordinat (0,208) dan (10, 209). Dari hasil pengujian, penerapan invers kinematika memiliki error terkecil sebesar 2.08% pada saat kaki kanan ke belakang dan yang terbesar 4.44% pada saat kaki kanan ke belakang dan kaki kiri ke belakang.