Analisis Kontrol Aliran Fluida Bervikositas Tinggi dengan Sensor Flow YF-S201 pada Otomatisasi Dispenser Minyak Goreng Hadi Supriyanto
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.311

Abstract

The purpose of Automation system on the Hygenist Automatic Frying Oil Dispenser making is to assist the frying oil sellers or suppliers in measuring the oil accurately and minimize the frying oil contamination. The dispenser is designed using pump and flowsensor to measure the frying oil pumped out. Electric valve or faucet is used to prevent contamination of the oil as the substitute of manual faucet. This study is focused on designing and making automation system on the frying oil dispenser, measuring time and volume accuracy of dispenser. Dispensers can be moved, capable of accommodating 50 Kg of oil and have a choice of two quantities; 500ml and 250ml.  As a result, flowsensor reading shows the same average frequency of 25 Hz and 35 Hz for filling 250 mL oil and 500 mL respectively. Time consumption for pumping 250 mL and 500 mL oil out from the dispenser is 8.85 s and 15,3 s respectively. Using delay program, the oil pumped out for 250 mL and 500 mL target volume need 5.75 s and 12 s delay time.
PERBANDINGAN PERFORMANSI LATENCY PROTOKOL KOMUNIKASI HTTP DAN MQTT PADA INTERNET OF THINGS Susetyo Bagas Bhaskoro; Hadi Supriyanto; Berlian Bayu Aji; Budi Pamungkas
Jurnal Teknologi Terapan Vol 8, No 2 (2022): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v8i2.309

Abstract

The objective of this study is to compare the performance (latency parameter) of HTTP and MQTT protocols. The latency parameter is the difference in time for a packet being transmitted and received. The tests are distinguished on different days and times. The results obtained are that the MQTT is better than HTTP. The results of the comparison values three times in a row are as follows: 46.6ms, 52.3ms, and 50.2ms
IMPLEMENTASI KONTROLER PID DENGAN METODE TUNING ZIEGLER-NICHOLS DAN COHEN-COON PADA SISTEM SCADA KENDALI LEVEL AIR Hadi Supriyanto; Fitria Suryatini; Abdur Rohman Harits Martawireja; Hendy Rudiansyah
Jurnal Teknologi Terapan Vol 8, No 2 (2022): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v8i2.410

Abstract

Didactics or mini plant teaching aids help students in colleges to understand the use of industrial equipment The SCADA-based water level control system is one of the teaching aid simulator equipment for monitoring and controlling water levels. In this research, PLC is used as a controller with three I/O modules  digital input module, digital output, and analog input and output. Arduino is also used as an analog output converter from PLC to actuator. The control method used is PID control. In the PID control, there are control parameters, namely Kp, Ki, and Kd. The third parameter was determined by the Ziegler-Nichols tuning method and compared with the Coohen-Coon method. The SCADA software that used is Wonderware Intouch on a system using a kepserver. The results of this study indicate that the Cohen-Coon tuning method for proportional control Kp = 1 produces the best response in water level control with a settling time of 21s and a rise time of 18s.
RANCANG BANGUN PRODUK SUBSTITUSI SISTEM DATA LOGGER ALIRAN DAN TEKANAN AIR PADA ALIRAN PIPA TERTUTUP MENGGUNAKAN KOMUNIKASI LoRaWAN Hadi Supriyanto; Wisnu Aji; Abdur Rohman Harits Martawireja; Sarosa Castrena Abadi; Sandy Bhawana Mulia; Wahyu Adhi Candra; Rizki Aji Pratama; Reka Adi; Naufaldo Naufaldo
Jurnal Teknologi Terapan Vol 10, No 2 (2024): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v10i2.624

Abstract

The availability of data loggers as data acquisition is still limited to sensor levels and the data loggers have not been produced in Indonesia. This makes it difficult for monitors to obtain data such as water pressure and water discharge data. The solution to this problem is to reduce the import cost of purchasing data loggers from abroad by developing data loggers that are able to take data on water level, water pressure. This study aims to determine how the design and performance of data logger system substitution products flow and water pressure using LoRa WAN communication. The test results show that the Water Flow and Pressure Data logger System functions according to the design that has been made with error readings from the itron cyble sensor of ?? and a pressure sensor reading error of 20.66%. The Packet Loss value of sending data from the data logger device is directly proportional to the distance where the smallest packet loss value is 13% at a distance of 50m and 80% at a distance of 2800m.