Karisma Trinanda Putra, Karisma Trinanda
Institut Teknologi Sepuluh Nopember, Surabaya

Published : 12 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 12 Documents
Search

Analysis of Reliability-based Systems of 20kv Distribution Network Disturbance on PT. PLN Rayon Panam Suripto, Slamet; Putra, Karisma Trinanda; Jusman, Yessi; Aroffi, Muhammad Rusydi Al; Jamaaluddin, Jamaaluddin
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3359

Abstract

Electricity needs for each year has increased, this is due to an increase in people's lives. Reliability is an important factor in the operation of distribution system and is an important factor in the continuity of the waiter to the consumer. Several parameters are used as reference to megukur level of reliability of a distribution system that is SAIFI (avarage interuption of frequency index system) is a calculation of the number of failures or disruptions average - average one year, SAIDI (System of interruption Duration Index) index median duration - average system interruption during the year. In this study was also performed calculations eens (Expected Energy Not Supplied) This calculation is done because of disturbance at each feeder there is energy that can not be channeled, it can happen losses. Based on the calculation and analysis that the reliability index is obtained there are some feeder Rayon Panam categorized as not reliable because it has a high SAIFI value not in accordance with the target SPLN No. 68-2 1986 and IEEE std 1366-2003. Energy losses that can not be distributed annually sizeable each feeder. This indicates a feeder located at Panam Rayon considered less reliable, to the need for repairs and maintenance
Analysis of Losses of propulsion systems on Electric Diesel Rail Trains Jamal, Agus; Chamim, Anna Nur Nazilah; Putra, Karisma Trinanda; Masfiyah, Nisfi Nurlailatul; Jusman, Yessi
Journal of Electrical Technology UMY Vol 2, No 3 (2018)
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.2338

Abstract

Train is one of transportation which supports the mobilization of society. Futhermore, it is affordable and comfortable so that people prefer using it. One of trains which is usually used by many people is KRDE or electric diesel railway, which is an innovation of technology in PT. INKA based on railway industry. It is one of railway that need electricity as the main source of energy that comes from alternator. it will handle all power of load needs on KRDE like as propulsion and auxiliary load. Therefore, the fluency of KRDE is affected by electrical system of the railway, which is mostly affected by propulsion load because it needs bigger power than auxiliary load. In this research presents about losses calculation on KRDE that are Three- phase rectifier, Variable Voltage Variable Frequency (VVVF) inverter and Three phase induction motor. Three phase rectifier and VVVF inverter will simulated by PSIM software to understand how the circuit work. The results of this research are explain about the number of loss energy in three phase rectifier is 21,6 Watt. In VVVF inverter and three induction motor, there are five samples. From analysis of the samples result that VVVF inverter has the highest efficiency 95,53% with loss energy 19,992 KW, which on 645 Volt about output voltage and 90 Hz about output frequency. In three phase induction motor, 91, 426% is the highest efficiency and it has 18,211 KW at loss energy, which on 635 Volt about input voltage and 36,38 Hz about input frequency. Then, the highest efficiency of propulsion system is 94,59% and 53,38 KW about loss energy, which on 635 Volt about input voltage and 36,38 Hz about input frequency in induction motor.