cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Radioisotop dan Radiofarmaka
ISSN : -     EISSN : -     DOI : -
Core Subject : Health,
Jurnal Radioisotop dan Radiofarmaka (Journal of Radioisotopes and Radiopharmaceuticals) bertujuan untuk memajukan ilmu pengetahuan dan teknologi di bidang radioisotop, radiofarmaka dan bidang terkait, yang diwujudkan dalam bentuk makalah ilmiah hasil penelitian atau tinjauan dan gagasan.
Arjuna Subject : -
Articles 5 Documents
Search results for , issue "Vol 12 (2009): JurnaL PRR 2009" : 5 Documents clear
PENGEMBANGAN DAN PENDAYAGUNAAN PRODUK RADIOISOTOP Suparman, Ibon; Lubis, Hotman
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3610.841 KB)

Abstract

ABSTRAK   PENGEMBANGAN DAN PENDAYAGUNAAN PRODUK RADIOISOTOP.   Pemanfaatan radioisotop untuk berbagai bidang, seperti bidang industri, hidrologi dan kedokteran nuklir menunjukkan  kecendrungan yang terus meningkat. Pusat Radio-isotop dan Radiofarmaka salah satu tugas pokoknya melakukan pengembangan dan pendayagunaan teknologi produksi radioisotop. Pada dekade terakhir (tahun 1999 sampai 2009) kegiatan pengembangan dan pendayagunaan -teknologi produksi radioisotop difokuskan pada kegiatan yang bisa langsung dimanfaatkan di berbagai bidang. Antara tahun 1999 and 2009 beberapa jenis radioisotop telah dikembangkan dan didayagunakan untuk berbagai bidang, antara lain 1251,153Sm, 203Hg, 86Rb, 1921r ( hair pin dan single pin), 166Ho, 186Re,60Co and 58CO(sebagai Co- Hexa-yancobaltate), 86Rb, 65Zn, 141Ce,46SC,35S, 198Au,45Ca, 41Ar (gas), dan 18p (radioisotop yang diproduksi melalui siklotron). I Untuk  preparasi 18p_PDG, fasilitas di PRR telah dilengkapi dengan 18p_PDG module. Dalam 5 tahun terakhir permintaan radioisotop 1-125 meningkat secara signifikan. Radioisotop 1-125 banyak digunakan untuk penelitian panas bumi, pembuatan kit radioimmunoassay (RIA) dan untuk brachytherapy kanker prostat dan kanker serviks. Ini berarti penyediaan radiosiotop 1-125 yang berkesinambungan merupakan faktor yang sangat penting. Untuk peme- nuhan kebutuhan radioisotop di dalam dan di luar negeri maka akan terus dilakukan pengembangan yang kontinu, baik untuk radioisotop yang dihasilkan dari siklotron maupun reaktor. Telah dikembangkan pula bebeberapa program komputer untuk sistem pemrosesan data dan dokumentasi, seperti program komputer untuk perhitungan iradiasi, radioaktivitas, spektrometri gama dan produk radioisotop 1-125. Dengan memanfaatkan program komputer ini operator yang berkaitan dengan proses radioisotop bisa bekerja lebih efisien dan terhindar dari kemungkinan kesalahan dalam pemrosesan data, juga data bisa diproses dan didokumentasikan lebih cepat dan akurat. Kata kunci: Pengembangan, pendayagunaan, produk radioisotope ABSTRACT DEVELOPMENT AND UTILIZATION OF RADIOISOTOPE PRODUCTS. The application of  radioisotopes in industry, hydrology and nuclear medicine increases year to year. One of the main tasks of the Center for Radioisotopes and Radiopharmaceuticals (PRR) is to develop and utilize radioisotope production technology. Por last decade (1999 up to 2009) the R & D activities at the PRR were focused on radioisotope production technology that can be applied directly in various fields. Between year 1999 and 2009 several radioisotopes have been developed and utilized e.g. 1251,153Sm,203Hg,86Rb, 1921r(hair pin and single pin) , 166Ho, 186Re, 60COand 58CO(as Co-Hexacyanocobaltate) , 86Rb, 65Zn, 141C,e 46SC, 35S, 198Au, 45Ca, 41Ar (gas), and 18p (cyclotron produced radioisotopes). Por 18p_PDG preparation, facility is already equipped  with 18p_PDGmodule. In last 5 years the demand of radioisotope 1-125 increased significantly. Radioisotope  1-125 is widely used for research on geothermal, preparation of radioimmunoassay (RIA) kit and for brachytherapy of prostate and cervix cancer. It means its continuity production is very important factor. Pulfilling domestic and overseas demand means continuity research for better products and progressive production techniques through R & D for cyclotron and reactor produced radioisotopes. Several computer program have been developed for data processing and documentation system, such as computer program for calculation of irradiation, radioactivity, gamma spectrometry and radioisotope 1-125 product. By applying this developed computer programs, the operator can work effectively and the data will be processed and documented accurately. Keywords: Development, utilization, radioisotope products
RELIABILITY ANALYSIS OF THE LIQUID TARGET CHAMBER FOR 18F PRODUCTION AT THE PRR'S CYCLOTRON FACILITIES Kambali, Imam; Sumantri, Tonny Heryanto; Rajiman, Rajiman; Ichwan, Syaefudin
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4861.532 KB)

Abstract

ABSTRACT RELIABILITY ANALYSIS OF THE LIQUID TARGET CHAMBER FOR 18F PRODUCTION AT THE PRR'S CYCLOTRON FACILITIES. The liquid target chamber for 18F production at the Cyclotron Division, Centre for Radioisotopes and Radio- pharma ceuticals (PRR) of them  Indonesian National Nuclear Energy Agency (BA TAN) has been analysed for its reliability in enduring high pressures and heat transfer requirements during proton beam bombardment as well as the recommended irradiation parameters for effective 18Fproduction. The target chamber was subject to house the 180-enriched water bombarded with high energy proton beam to produce 18F.A range of SRIM-computer simulations have also been conducted to calculate the ranges of several energetic proton beams (of up to 20 MeV) into pure water target. A study of radioactive impurities which might be produced from the proton-irradiated chamber's materials was also included based on some references. Due to concern over the heat produced during target irradiation, a heat transfer analysis - particularly for the target's cavity - was also included in the presented studies to obtain a brief preliminary calculation of the heating impacts prior to irradiation tests. The calculation was performed for various proton beam currents and energies of up to 30 J..lAand 20 MeV. respectively. It was found that the chamber was reliable for production of 18Ffrom proton irradiated-180 enriched-water target by maintaining the chamber's pressure of up to 3.6 bar if the proton beam current was kept below 16 J..lAfor all energies or the proton beam energy was kept to or below 10 MeV for any employed beam currents. The overall heat transfer coefficient was also found to depend on the power deposited into the water target. Keywords: reliability analysis, liquid target chamber, 18F production, proton irradiation, cyclotron, 180_enriched water target, heat transfer coefficient. ABSTRAK ANALISIS KEHANDALAN CHAMBER TARGET CAIR UNTUK PRODUKSI 18F DI FASILITAS SIKLOTRON PRR. Telah dilakukan analisis kehandalan terhadap chamber target cair untuk produksi 18F yang dimiliki oleh Bidang Siklotron, Pusat Radioisotop dan Radiofarmaka (PRR), Badan Tenaga Nuklir Nasional (BATAN) dalam menahan beban tekanan tinggi dan transfer panas selama proses iradiasi berkas proton, serta rekomendasi parameter iradiasi yang efektifuntuk produksi 18F.Chamber target  cair terse but dibuat sebagai wadah air yang diperkaya dengan 180 yang selanjutnya diiradiasi dengan berkasproton berenergi tinggi untuk produksi 18F. Simulasi computer menggunakan program SRIM juga dilakukan untuk menentukan jangkauan berkas proton berenergi tinggi (sampai dengan 20 MeV) kedalam target air mumi. Impuritas radioaktif yang mungkin dihasilkan dari material penyusun chamber tersebut akibat iradiasiberkas proton juga dibahas berdasarkan hasil studi literatur. Analisis transfer panas juga dilaksanakan oleh karena adanya kekhawatiran terhadap panas yang dihasilkan selama iradiasi target, terutama di dalam ruang target, untuk mendapatkan hasil perhitungan awal terhadap kalor yang dihasilkan sebelum uji coba iradiasi. Perhitungan tersebut dilakukan untuk berbagai arus dan energi berkas proton (masing-masing sampai 30 µ dan 20 MeV). Hasil perhitungan dan eksperimen awal menunjukkan bahwa chamber target cair tersebut dapat dihandalkan untuk memproduksi 18F dari target air yang diperkaya 180 dengan mempertahankan tekanan chamber sebesar 3,6 bar jika arus berkas proton dipertahankan sebesar 16 J..lAuntuk semua energi atau jika energi berkas proton dipertahankan sebesar/ dibawah 10 MeV untuk setiap arus. Hasil analisis juga menunjukkan bahwa koefisien transfer panas keseluruhan tergantung pada daya yang diterima oleh target cair terse but.Kata kunci : analisis kehandalan, chamber target cair, produksi 18F, iradiasi proton, siklotron, target air yang diperkaya 18O,koefisien transfer panas.
KARAKTERISTIK SENYAWA PENGKONTRAS MAGNETIC RESONANCE IMAGING GADOLINIUM(III)-DTP A DALAM TUBUH HEW AN PERCOBAAN MELALUI SIMULASI 153Gd_DTPA SEBAGAI TRACER. Gunawan, Adang Hardi; Muthalib, Abdul; Lestyawati, Sri Aguswarini; Haryuni, Ratna Dini
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (7731.593 KB)

Abstract

ABSTRAK KARAKTERISTIK SENYAWA PENGKONTRAS MAGNETIC RESONANCE IMAGING GADOLINIUM(III)-DTP A DALAM TUBUH HEW AN PERCOBAAN MELALUI SIMULASI 153Gd_DTPA SEBAGAI TRACER. Perilaku senyawa pengkontras MRI (Magnetic Resonance Imaging) GdDTP A di dalam tubuh dapat dipelajari dengan mengamati biodistribusi di dalam jaringan tubuh serta laju clearance baik dalam urin maupun feces dengan menggunakan hewan percobaan. Kestabilannya di dalam aliran darah dapat diamati melalui penguraiannya di dalam serum darah setelah diinkubasi pada suhu tubuh. Studi ini perlu dilakukan karena erat kaitannya dengan aspek khasiat (efficacy) dan keselamatan (safety) penggunaan senyawa pengkontras untuk MRI. Dalam laporan ini akan disampaikan hasil uji biodistribusi, clearance, serta kestabilan senyawa komplek Gd-DTP A di dalam serum darah dengan mengunakan senyawa bertanda I53Gd-DTPA. Komplek 153Gd_DTPAdisintesis sarna seperti sintesis Gd-DTPA, yaitu dengan mensuspensikan DTPA (diethylenetriaminepentaacetic acid) dalam larutan 153GdCb, kemudian suspensi direfluks selama 1 jam dan diperoleh larutan jemih 153Gd_DTPA.Kemumian radiokimia komplek 153Gd_DTPAditentukan melalui pengukuran dengan elektroforesa kertas dan kemumiannya diperoleh lebih besar dari 95 %. Uji biodistribusi senyawa komplek 153Gd_DTPA dilakukan terhadap mencit dan uji yang sarna dilakukan pula terhadap 53GdCb untuk melihat biodistribusi Gd3+ bebas. Hasil percobaan menunjukkan bahwa ion 153Gd3+bebas terakumulasi di beberapa organ seperti hati, jantung, paru dan limp a sedangkan akumulasi senyawa komplek 53Gd_DTPA pada ginjal dicapai dalam waktu 2 jam setelah penyuntikan. Clearance komplek 153Gd_DTPA dalam urin dan feces lebih dari 95% setelah 48 jam penyuntikan dan aktivitas yang tersisa dalam tubuh hewan kurang dari 5%. Kestabilan senyawa kompleks dalam plasma darah pada suhu 37° C masih bertahan diatas 24 jam yang ditunjukkan oleh integritas senyawa kompleks dalam bentuk kemurnian radiokimianya masih diatas 95%.Kata kunci: 153Gd_DTPA, biodistribusi, clearance, kestabilan, MRI ABSTRACT CHARACTERISTIC OF MAGNETIC RESONANCE IMAGING CONTRAST AGENT GADOLINIUM(III)-DTPA IN ANIMAL SIMULATED BY RADIOTRACER 153Gd_DTPA. Characteristic of MRI contrast agent Gd-DTP A in the body can be studied by observing the stability in blood serum, biodistribution study in organ/tissues and clearance of the complex in urine and feces by using animal model. This study was performed in connection with efficacy and safety aspect of a Gd-DTP A complex as an MRI contrast agent. Gadolinium-I53 DTPA was prepared by suspending of DTPA (diethylenetriaminepentaacetic acid) in GdCb solution in 1N HCI. The suspension was refluxed for one hour until the clear solution of 153Gd_DTPA obtained. Radiochemical purities of both 153GdCb and 153Gd_ DTP A showed more than 95 % by mean of TLC and paper electrophoresis. The biodistribution studies of the 153GdCband 153Gd_DTPAwere performed using normal white mice with the aim of evaluating the side effects of Gd ions and the efficacy of the complex Gd-DTPA. Stability test of 153GdDTP A was done by using blood human serum and observed quite stable up to 116 hours. Biodistribution pattern of 153Gdion tends to accumulate in the organs such as liver, heart, lung and spleen, while 153Gd_DTPA complex accumulates with optimum activity in the kidney 2 hours after injection. Clearance of I53Gd-DTPA  in the urine and feces showed more than 95 % at 48 h after injection and less than 5 % of the activity still remains in the body, Stability test of 153Gd_DTPAcomplex indicated that the complex was stable up to 50 hours after preparation. Keywords :  153Gd_DTPA,biodistribution, clearance, MRI
VALIDASI METODE PEMBUATAN DAN KENDALl MUTU KIT UBIQUICIDINE UNTUK DETEKSI INFEKSI Widjaksana, Widyastuti; Roseliana, Anna; Lestari, Enny; Tahyan, Yayan; Setyowati, Sri; Humani, Titis Sekar; Kartamihardja, Hussein S
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3590.876 KB)

Abstract

ABSTRAK VALIDASI  METODE  PEMBUATAN  DAN  KENDALl  MUTU  KIT UBIQUICIDINE  UNTUK  DETEKSI INFEKSI. Telah dilakukan pembuatan dan uji mutu radiofarmaka Ubiquicidine 29-41 (UBI 2941)untuk ditandai dengan teknesium 99mTcyang akan digunakan untuk preparat diagnosis infeksi bakteriGram posistif dan jamur. Kit kering UBI telah dibuat secara aseptis dan dianalisis kemumian radiokimia, sterilitas dan apirogenitasnya. HasH penandaan UBI dengan 99mTcdianalisis dengan kromatografi lapis tipis dan kromatografi kertas menggunakan ITLC-SG dengan eluen campuran dapar ammonium asetat 0.1 M 5.2 - metanol (1: I) serta kertas Whatman-l dengan e1uen aseton, sedangkan uji sterilitasnya dilakukan menggunakan medium perbenihan cair Fluid Thioglycolate (FTG) dan Trypton Soy Broth (TSB). Uji in vivo pada hewan percobaan dilakukan pada mencit normal dan yang diinduksi infeksi, sedangkan uji klinis pendahuluan dilakukan pada 5 orang relawan di RS. Hasan Sadikin Bandung dan RSPAD Gatot Soebroto Jakarta yang I orang diantaranya mewakili pasien sehat, dan waktu pengamatan dilakukan pada I jam dan 2 jam setelah penyuntikan dengan 99mTc_UBI.Hasil percobaan menunjukkan efisiensi penandaan sebesar 99,34%, uji sterilitas menunjukkan tidak terjadi pertumbuhan mikroba dalam media uji, uji pirogenitas tidak menunjukkan kenaikan temperatur yang berarti pada kelinci percobaan dan stabilitas kit kering UBI pada penyimpanan di suhu 4°C tidak berubah hingga 12 bulan pengamatan. Biodistribusi pada mencit normal menunjukkan akumulasi radioaktivitas pada ginjal dan kandung kemih, sedangkan pad a mencit yang diinfeksi terlihat adanya penangkapan yang signifikan' pada jaringan yang mengalami infeksi (paha kanan) dibandingkan jaringan yang sehat (paha kiri). Studi pendahuluan pada pasien normal menunjukkan akumulasi radioaktivitas pad a ginjal dan kandung kemih sedangkan pada pasien dengan gejala diare maupun hemoroid terlihat juga adanya penangkapan yang signifikan pada usus dan penangkapan radioaktivitas terse but terlihilt lebih jelas setelah 2 jam. Telah dibuktikan pula kespesifikan dalam pencitraan infeksi bakteri dibandingkan dengan non bakteri (amuba). Hal ini menunjukkan bahwa radiofarmaka 99mTc-Ubiquicidine 29-41 dapat digunakan untuk mendeteksi adanya infeksi secara umum dalam tubuh menggunakan kamera gama dengan waktu pencitraan optimal 2 jam sekaligus juga dapat membedakan antara infeksi yang disebabkan oleh bakteri dan non bakteri. Kata kunci: 99mTc,penandaan, Ubiquicidine, biodistribusi, infeksi ABSTRACT VALIDATION OF PREPARATION AND QUALITY CONTROL METHODS OF UBIQUICIDINE KIT TO BE USED AS INFECTION IMAGING AGENT. Preparation and Quality Control of Ubiquicidine 29-41 (UBI 29-41) to be labelled with 99mTchave been carried out and will be prepared as infection imaging agent specifically for Gram positive bacteria-and fungi. Lyophilised UBI kits was prepared aseptically and analysed for its sterility, apyrogenicity and radiochemical purity. Labeling efficiency of UBI was analysed by thin layer chromatography using ITLC-SG with ammonium acetate 0.1 M pH 5.2-methanol (1: I) as eluants and paper chromatography using Whatman-I paper with acetone as eluant, and its sterility was assesed using bacterial and fungal culture media, i.e fluid thioglycolate (FTG)and trypton soy broth (TSB). In vivo study was carried out in normal mice and infection induced mice, whereas initial clinical study was carried out on 5 volunteers at Hasan Sadikin General Hospital and Gatot Soebroto Army Hospital, which 1 of them represents normal patient. The images were taken I hour and 2 hours post administration. QC results showed labelling efficiency of UBI of 99.34%, no microorganisms growth in culture media, no significant increase in temperature of experimental rabbits and the stability of unlabeled UBI kits during storage at 4°C was unchanged up to 12 months. Biodistribution study in normal mice showed high accumulation in kidneys and bladder, whereas in infected mice higher uptake was alsoobserved in infected area (right thigh) rather than in uninfected one (left thigh). Initial clinical study in normal patient showed high accumulation of radioactivity in kidneys and bladder whereas in 2 patients with symptoms of diarrhoea and haemorroid respectively the uptake was also seen in colon which increased after 2 hours. Uptake of radioactivity was also seen in patient with spondy litis TB but none in patient with amoebic infection who was previously proven infected using other modality. From this experiment it can be concluded that Ubiquicidine 29-41 labeled with 99mTccan be used as infection imaging agent using gamma camera with optimum scanning time of 2 hours post injection and enable to differentiate between bacterial infection and amoebic infection.Keywords: 99mTc,labeling, Ubiquicidine, biodistribution, infection
UNJUK KERJA GENERATOR 99Mo/99mT DENGAN RADIOAKTIVITAS 99Mo 600 DAN 800 mCi BERBASIS PZC Kadarisman, Kadarisman; Gunawan, Adang Hardi; Lubis, Hotman; Herlina, Herlina; Sriyono, Sriyono; Abidin, Abidin
Jurnal Radioisotop dan Radiofarmaka Vol 12 (2009): JurnaL PRR 2009
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4335.436 KB)

Abstract

ABSTRAK UNJUK KERJA GENERATOR 99Mo/99mTc DENGAN  RADIOAKTIVITAS 99Mo 600 DAN 800 mCi  BERBASIS  PZc. Radioisotop 99mTc mempunyai umur paro pendek (6 jam), pemancar sinar gamma mono-energik (140 KeV), mudah membentuk senyawa komplek dengan berbagai kit, dan tidak memancarkan partikel beta, maka 99mTcmerupakan radionuklida paling ideal untuk diagnosis dibidang kesehatan dibandingkan dengan radionuklida lainnya, sehingga diagnosis kedokteran nuklir menggunakan radionuklida ini lebih 80% dari diagnosis menggunakan radioisotop di seluruh dunia dan ada sekitar 9 juta prosedur untuk diagnosis. Beberapa jenis generator 99Mo/99mTc telah dikembangkan dan dikomersialkan, sistem ekstraksi menggunakan Metil Etil Keton (MEK), produk 99mTc terkontaminasi MEK, system kromatografi alumina, kapasitas serap alumina untuk 99Mo kecil, harus menggunakan 99Mo fisi, sistem gel Zr-Mo atau Ti-Mo tidak reprodusibel, yang terakhir adalah sistem Polymer Zirconium Compound (PZC). PZC berkapasitas serap tinggi untuk 99Mo,dapat menggunakan 99Mo hasil reaksi (n,y) yang lebih murah dan hasil radionuklida 99mTclebih terjangkau, teknologi tidak rumit dan proses relatif sederhana. Akhir-akhir ini, sistem generator 99mTc berbasis PZC telah dipelajari secara mendalam meliputi profit elusi 99mTc menggunakan salin, kapasitas serap PZC terhadap 99Mo, kemurnian radionuklioda 99mTcdan kestabilan PZC. Namun perkembangan pengembangan itu baru menggunakan tingkat radioaktivitas 99Mo relatif rendah (maksimum 272 mCi), sedangkan dalam generator 99mTcminimal harus berisi 300 mCi sid 1000 mCi 99Mo. Dalam penelitian ini telah dilakukan pembuatan kolom Mo-PZC dengan tingkat radioaktivitas tinggi (600dan 800 mCi) dengan menggunakan PZC sebanyak 5,86 dan 4,42 gram. Dalam eksperimen ini diperoleh radioaktivitas 99mTc243,86 dan 308,59 mCi dengan kemurnian radionuklida masing-masing sebesar 1,87 x 10-2 dan 1,32 x 10-2 ~Ci 99Mo/mCi 99mTc.Matriks 99Mo_PZC mempunyai ukuran patikel lebih kecil, yaitu berkisar antara 0,456 sid 0,583 I-lm.Kata kunci : Generator radioisotop 99Mo/99mTc,radioisotop 99Mo,PZC, lolosan 99Mo ABSTRACT PERFORMANCE OF 99Mo/99mTc GENERATORS WITH 600 AND 800 mCi RADIOACTIVITY OF 99Mo BASED ON PZC. Radioisotope of 99mTchas half life of 6 hours, emit mono-energic gamma ray (140 KeV), easily form complex compound with various kit, and does not emit beta particle. The 99mTc represents ideal radioisotope for diagnosis in health field compared to other radionuclides. More than 80% of the diagnosis in nuclear medicine uses the radionuclide and there is about 9 million procedures for diagnosis all over the world. Some types of generator of 99Mo/99mTchave been developed and commercially used. In the extraction system using Methyl Ethyl Keton (MEK), the produced 99mTcwas contaminated by MEK, while in chromatography using alumina, the absorbent capacity of alumina for 99Mo is small and can be used for 99Mo fission product only. Generators using gel of Zr-Mo or Ti-Mo are not reproducible. The generator system developed recently was generator using Polymer Zirconium Compound (PZC) as the adsorbent. PZC have high absorption capacities for 99Mo and can be used for 99Mo from (n,y) reaction. The cost of the generator is relatively low, the technology is not complicated and the process is relatively simple. Generator system of 99mTc based on PZC have been studied intensively including elution profile of 99mTcusing saline solution, absorbtion capacity of PZC for 99Mo, radionuclide impurities in 99mTcand stability of PZC. However, the radioactivity  of  99 Mo used is still relatively low (maximum 272 mCi), while in 99Mo/99mTcgenerator, the radioactivity of 99Mo is in the range of 300 mCi to 1000 mCi 99Mo. In this research, the experiment of generators with high radioactivity of 99Mo (6 mCi) was carried out. In this experiment, 99mTc with  radioactivity of 243.86 and 308.59 mCi was obtained. The Impurity of 99Mo break through were 1,87 x 10-2 and 1,32 x 10'2 f.!Ci 99Mo/mCi 99mTc.The matrix of 99I't10-PZChave small size, in the range of 0,456 to 0,583 f.!m.Key words : 99Mo/99mTc isotope generator, 99Mo isotope, PZC, 99Mo break through.00 – 800

Page 1 of 1 | Total Record : 5