Claim Missing Document
Check
Articles

Found 7 Documents
Search

Implementasi Sistem Komunikasi FM Pada Prototype Pendeteksi Dini Gempa Atik Charisma; Een Taryana; Dede Irawan Saputra; Muhammad Burhannudin Misuari; Aldi Setiawan; Faisal Dharmawan
PROtek : Jurnal Ilmiah Teknik Elektro Vol 7, No 2 (2020): PRotek : Jurnal Ilmiah Teknik Elektro
Publisher : Program Studi Teknik Elektro Universitas Khairun

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33387/protk.v7i2.1812

Abstract

An earthquake is a vibration that occurs due to plates at the base of the earth rubbing against each other. An earthquake can have several impacts, namely material loss and loss of life and trauma for some people who feel it. This happens because people are not fast enough in getting information. Therefore we need an earthquake detection device that is relatively inexpensive. In this study designed a prototype for earthquake early detection using Frequency Modulation (FM) communication. The components of this system are Arduino Uno which functions as a microcontroller, SW-420 vibration sensor to detect vibrations, buzzer as the output of the SW-420 sensor in the form of sound and FM transmitter V2.0 which functions as a medium for transmitting radio frequency signals and sending sound from the buzzer . The level of vibration that indicates that an earthquake occurred namely 3-5 with a conversion of 5-10 SR. The system would have the ability to provide information in the form of sound received by a radio or FM receiver. The distance that can be emitted by the FM transmitter module V2.0 is 17.87 meter
Rancang Bangun On-line Monitoring System untuk pH Air MenggunakanPH- 4502C Module dan Aplikasi WebServer Atik Charisma; Handoko Rusiana Iskandar; Een Taryana; Henda Nurfajar
Prosiding Semnastek PROSIDING SEMNASTEK 2019
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Air memiliki peran yang sangat penting dalam menunjang keberlangsungan hidup manusia. Air diperlukan untuk berbagai kebutuhan penunjang lainseperti dibidang industri, pertanian, tempat umum dan konsumsi rumah tangga. Pada bidang industri penggunaan air yang digunakan sangat berperan penting dalam melakukan operasional di perusahaan. Berbagai pengawasan telah dilakukan untuk mengetahui kualitas air yang digunakan. Kesulitan yang dihadapi engineer setiap perusahaan yaitu dalam melakukan pengambilan data masih menggunakan metode manual sehingga memerlukan delayyang lebih lama. Maka dari itu diperlukan sistem yang dapat melakukan monitoring secara realtime sehingga dapat memudahkan engineer dalam mengolah data monitoring kualitas air. Perancangan monitoring kualitas air menggunakan beberapa komponen yaitu mikrokontroler arduino uno, modul Ethernet shield,pH module, dan sensor probe pH. Sistem ini akan bekerja dengan sensor pH yang berfungsi sebagai pendeteksi nilai pH berdasarkan perubahan tegangan pada probe pH, data dari sensor selanjutnya diolah oleh arduino secara realtime dan ditampilkan pada layar LCD dan dimonitor dalam aplikasi webserver. Aplikasi web menampilkan status asam, netral, basa dan melakukan logging kedalam tabel serta grafik. Alat monitoring pH ini mampu melakukan pembacaan pada pH dalam kategori asam, netral dan basa. Respon sistem dari alat ini yaitu 1,93 detik sedangkan presentase efisiensi sensor yang dihasilkan berdasarkan pengujiansebesar 94,16%.
Susut Daya Akibat Ketidakseimbangan Beban pada Saluran Distribusi Tegangan Rendah Een Taryana
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 10 No 1 (2011): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26874/jt.vol10no1.174

Abstract

Pada sistem pembebanan yang tidak seimbang dalam sistem tiga-fasa empat-kawat, susut daya pada saluran distribusi akan lebih besar dibandingkan pada kondisi beban tidak seimbang. Hasil analisis menunjukkan bahwa pada kondisi pembebanan yang ekstrim dimana beban hanya terpasang pada salah satu fasa saja susut daya pada saluran distribusi akan lebih besar enam kali dibandingkan pada kondisi beban seimbang.
Sistem Komunikasi Audio dengan Teknologi Visible Light Communication (VLC) Menggunakan Laser Led Atik Charisma; Rizky Nur Akbar Setiawan; Een Taryana; Hajiar Yuliana; Alifa Rike Indriani
Digital Zone: Jurnal Teknologi Informasi dan Komunikasi Vol. 12 No. 2 (2021): Digital Zone: Jurnal Teknologi Informasi dan Komunikasi
Publisher : Publisher: Fakultas Ilmu Komputer, Institution: Universitas Lancang Kuning

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/digitalzone.v12i2.7519

Abstract

Kegiatan masyarakat di era sekarang yang serba digital menggunakan teknologi tanpa kabel (wireless). Teknologi tanpa kabel menjadi andalan komunikasi, namun seiring perkembangann zaman, ada sebuah teknologi tanpa kabel dengan memanfaatkan cahaya tampak. Teknologi ini dikenal dengan istilah visible light communication (VLC). Sistem VLC terdiri dari bagian transmitter dan receiver. Transmitter berupa komponen-komponen elektronika yang terintegrasi dengan cahaya tampak sebagai media transmisi. Pada penelitian ini membuat bagian transmitter dan receiver untuk komunikasi audio. Cahaya tampak sebagai media transmisi menggunakan laser led karena cahaya dari laser led ini lebih fokus dan pancaran cahayanya lebih jauh dibandingkan dengan yang lain. Sedangkan di sisi receiver menggunakan solar panel sebagai penerima sinyal informasi yang dikirimkan. Penelitian ini berhasil membuat sebuah sistem komunikasi audio berbasis visible light communication. Variasi jarak antara transmitter dan receiver mempengaruhi kualitas suara yang diterima. Pada jarak 500 cm kualitas suara yaitu 99,2 dB pada kondisi gelap dan 99,1 dB kondisi terang. Perubahan sudut pancar transmitter terhadap receiver juga mempengaruhi hasil kualitas suara. Kualitas suara terbaik pada sudut 900 di kondisi terang dengan jarak 50 cm sebesar 97,9 dB sedangkan di kondisi gelap dengan jarak 50 cm pada sudut 1000 sebesar 98,1 dB. Abstract The people activities in today's digital era use wireless technology. Wireless technology has become the mainstay of communication, but along with the times, there is a wireless technology that uses visible light. This technology is known as visible light communication (VLC). The VLC system consist of transmitter and receiver. Transmitters are electronic components that are integrated with visible light as a transmission medium. In this study, the transmitter and receiver are made for audio communication. Visible light as a transmission medium uses an LED laser because the light from this LED laser is more focused and the light beam is farther away than the others. While on the receiver side using a solar panel as a receiver of the information signal that is sent. This research succeeded in making an audio communication system based on visible light communication. Variations in the distance between the transmitter and receiver affect the quality of the received sound. At a distance of 500 cm in dark conditions, the sound quality is 99.2 dB in light conditions and 99.1 dB. Changes in the beam angle of tranmitter to receiver also affect the sound quality. The best sound quality at an angle of 900 in bright conditions with a distance of 50 cm is 97.9 dB while in dark conditions with a distance of 50 cm at an angle of 1000 is 98.1 dB.
STUDI PENAMBAHAN GARDU SISIPAN TIPE TIANG UNTUK MENGATASI BEBAN LEBIH DI PT PLN (PERSERO) AREA CIANJUR RAYON MANDE Giri Angga Setia; Hadi Umar Setiawan; Fauzia Haz; Een Taryana
EPSILON: Journal of Electrical Engineering and Information Technology Vol 20 No 2 (2022): EPSILON: Journal of Electrical Engineering and Information Technology
Publisher : Department of Electrical Engineering, UNJANI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55893/epsilon.v20i2.95

Abstract

In the distribution system, blackouts caused by excessive loads cause losses for both consumers and electricity providers. Based on this, it is necessary to analyze the addition of distribution substations using an accurate methodology so that when applied it can be a solution to the need for electrical energi. Several stages of the method are determining the specifications of each component, calculating the optimal capacity of each component, measuring the voltage value contained in the panel and the primary part of the transformer at the hook-up substation, and simulating using ETAP software. The cantol substation was chosen because field studies have been carried out according to load requirements. The results of the calculation analysis show that with the addition of insertion substations, the total power becomes 100 kVA. The measured load at night is 77.7 kVA and during the day is 67.5 kVA. This indicates that the loading is in the allowable standard range below 80%. The voltage increased to 0.9828 per unit from the previous condition where there was a voltage drop of 11%. So that the load needs are met on demand.
Studi Kejenuhan pada Current Transformer (CT) Akibat Arus Hubung Singkat Giri Angga Setia; Een Taryana; Naufal Nur Aiman; Ahmad Daelami; Hikmah Prasetia
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 22 No 1 (2023): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55893/jt.vol22no1.535

Abstract

The CT saturation analysis approach model was carried out using ATPDraw and Mathcad software simulations. Input simulation data obtained from CT testing at West Priok Substation, namely ratio, excitation curve V-rms-Irms, Rct. Based on the simulation results, the CT model was successfully implemented for CT conditions at the West Priok Substation which experienced saturation, as seen from the results of the distorted waveforms and the THDi value of 40.612%. These results are then compared with the IEC 61869-2 standard with the parameters obtained from the CT-Analyzer test on E-t, Ek, Ie, Kx, and Rct, that E-t is -1%, Ek is 635.25 V, Ie is 13.5 mA, Kx of 0.084 and Rct of 7432.57 ohm. This result is a deviation from the specified standard, meaning that the CT is damaged and saturated. After replacing the CT, it was tested again and the value of E-t was -0.010%, Ek was 936.09 V, Ie was 9.68 mA, Kx was 14.39 A, Rct was 4.226 ohm, and the waveform simulation results were not distorted, then the THDi value obtained by 0.08%. This indicates that the CT is in good condition and does not experience saturation when the short circuit current is 20 kA.
Techno-economic Analysis and Optimization of Renewable Energy Forecasting at Universitas Jenderal Achmad Yani Handoko Rusiana Iskandar; Azhar Nurfatah; Ahmad Daelami; Een Taryana
ELECTRON Jurnal Ilmiah Teknik Elektro Vol 4 No 2: Jurnal Electron, November 2023
Publisher : Jurusan Teknik Elektro Fakultas Teknik Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/electron.v4i2.52

Abstract

The availability of electrical energy ensures operational sustainability in everyday life, including the educational environment. The possibility of easier renewable energy installation encourages the goal of growing the installation to be affordable. Universitas Jenderal Achmad Yani is one of the campuses that has the capacity to use renewable energy and has a role in environmental awareness in accordance with the university's future vision. In light of this, a hybrid photovoltaic (PV), diesel, and battery plant design is presented as an alternative power plant to supplement conventional energy sources. However, it is critical to examine the long-term capital and profit estimations that must be considered. The hybrid plant is proposed in two configurations, grid-connected and off-grid. In this paper, modeling and simulation are performed using Net Present Cost (NPC) prices from the Ministry of Energy and Mineral Resources (MEMR) rooftop PV installation planning guidelines and inflation estimations from the Republic of Indonesia's Ministry of Finance. Furthermore, until the contribution of energy generated in the simulation is displayed, the production and consumption of electrical energy required for the selected building instances are generated. Hybrid plant modeling has been completed at Universitas Jenderal Achmad Yani’s Faculty of Health Sciences and Technology (FHST) and Rectorate buildings. According to the simulation results, the NPC cost for the next 25 years is anticipated to be Rp 1,047,534,000, with a total electrical energy production of 729,807 kWh/year and a renewable energy contribution >91.4%. Furthermore, from a technological and economic standpoint, a grid-connected hybrid generation system is advocated