Claim Missing Document
Check
Articles

Found 21 Documents
Search

Optimal Sizing of Micro Hydropower to Improve Hybrid Renewable Power System Syafii Syafii; Heru Dibyo Laksono; Novizon Novizon; Rahmad Fahreza
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 7, No 1: EECSI 2020
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eecsi.v7.2094

Abstract

This paper presents an analysis of optimal micro hydropower (MH) capacity of hybrid systems to improve renewable energy based power systems. The electricity system was designed by considering river water flow data and solar radiation data at the research location, Andalas University. Optimal results obtained for the configuration of the Grid, MH, and PV with a head height of 30 m and a flow rate of 800 L/s with the lowest COE value of $ 0.065. As an optimal sizing system has been able to increase the composition of renewable energy generation in the Unand electrical network. The renewable energy fraction has increased from 26.4% to 36.5%. Therefore, determining the optimal capacity will increase the use of renewable energy generation. Conversely, an increase in electricity supply from renewable energy plants will reduce electricity consumption from the PLN grid. The latest excess power generation at a low load can be sold to the PLN grid
Pelatihan dan Pendampingan Jaringan Komputer dengan Mikrotik di Pondok Pesantren Modern Terpadu Dr. Muhammad Natsir Alahan Panjang Kabupaten Solok Heru Dibyo Laksono; Reri Afrianita; Mumuh Muharram; Novizon Novizon
Warta Pengabdian Andalas Vol 28 No 2 (2021)
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jwa.28.2.76-83.2021

Abstract

Training of Computer network using Miktrotik at the Integrated Modern Islamic Boarding School of Dr. Muhammad Natsir at Alahan Panjang is one of the solutions to overcome the problem of the effectiveness and efficiency computer user. The training was started by a field survey to laboratory of the information and communication technology (ICT) at the School. In this survey, discussions were held on what problems are very important and get priority to find solutions in increasing the effectiveness and efficiency of computer use at the School. The results of the survey agreed that computer network training with Mikrotik would be held in order to increase the effectiveness and efficiency of computer use on it. The second activity was the preparation of computer network training with Mikrotik. Preparation was carried out in the form of discussions with teammates to determine materials and methods that were more efficient and effective in the implementation of computer network training with Mikrotik at the Information and Communication Technology (ICT) laboratory. The results of the discussion agreed that the training would be provided in the form of presentations and hands-on practice. The third activity was the implementation of computer network training with mikrotik. This training was provided for 2 days, namely Saturday and Sunday. The first day was done by shared knowledge about the basics of computer networks and Mikrotik. The second day, students did a computer network training with Mikrotik. The fourth activity was the evaluation of computer network training activities with Mikrotik, to evaluate the activities that have been carried out and to obtain suggestions and input for future improvements.
Sistem Pengatur Tegangan Otomatis : Analisa Peralihan Dengan Pengendali Tunggal Dan Kaskade Heru Dibyo Laksono; Novizon Novizon; Melda Latif; Eko Amri Gunawan; Reri Afrianita
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol 11, No 2 (2021): Amplifier November 2021 Vol 11 No 2
Publisher : Universitas Bengkulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v11i2.19133

Abstract

This journal describes the design and analysis of the response of a single controller and cascade direct current type of Automatic Voltage Regulator (AVR) system. The direct current AVR system is represented form of a transfer function. For single and cascade controllers, it is designed using a parallel architecture using MATLAB software with predetermined design criteria. The types of controllers used consist of Proportional Differential (PD), Proportional Integral (PI), Proportional Integral Differential (PID), Proportional Differential with First Order Filters in the Differential Section (PDF) and Proportional Integral Differentials with First Order Filters in the Differential Section(PIDF). For the transition analysis, the observed parameters consist of rise time, peak time, steady state time, maximum pass value and peak value. The results of the analysis show that the controllers that meet the design criteria are Proportional Differential (PD) controllers and Proportional Differential controllers with First Order Filters in Differential Sections (PDF) for single controllers and cascade controllers. For a single controller, the value of the Proportional constant (Kp) is 0.6280 and the value of the Differential constant (KD) is 0.1710 for the Proportional Differential (PD) controller. Proportional constant value (Kp) is 0.6130, Differential constant value (KD) is 0.1710 and filter constant value (Tf) is 0.0009 for Proportional Differential controller with First Order Filter in Differential Section (PDF). Cascade controllers and Proportional Differential (PD) controllers, the Proportional constant (Kp) is 1.7300 and the Differential constant (KD) is 0.0242 for the inner circle (C2). Outer ring controller (C1), the proportional constant (Kp) is 179,000 and the Differential constant (KD) is 2.4600. Cascade controllers and Proportional Differential controller types with First Order Filters in the Differential Section (PDF), the Proportional constant (Kp) value is 1.5900, the Differential constant (KD) value is 0.0246, the filter constant value (Tf) is 0.0018 for the inner circumference (C2 ). For the outer ring controller (C1), the Proportional constant (Kp) value is 134,0000, the Differential constant (KD) value is 2.2900 and the filter constant value (Tf) is 0.00008.
Fault Type Classification of 150 kV Transmission Line using Wavelet Multi-Resolution Analysis Method Novizon Novizon; Nurfi Syahri; Silvia Wulandari; Tesya Uldira Septiyeni; Rahadian Asneli Putri
Andalas Journal of Electrical and Electronic Engineering Technology Vol. 1 No. 2 (2021): November 2021
Publisher : Electrical Engineering Dept, Engineering Faculty, Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (341.451 KB) | DOI: 10.25077/ajeeet.v1i2.15

Abstract

To identify the fault, wavelet method is used in solving complex protection problems. This study uses a new approach, namely the wavelet multi resolution analysis method with its application where multi resolution analysis works to analyze signals at different frequencies with the same resolution. In this study, the classification of fault types that occur in the 150 kV transmission line quickly and accurately is carried out using the wavelet multi resolution analysis method. This research is included in applied research and was designed using computer simulation software, namely ATP and MATLAB. The data transmission system used is the Maninjau Hydroelectric Power Plant transmission line to Pauh Limo Substation. The modeled transmission system is given 1-phase to ground, 2-phase to ground, 2- phase, 3-phase and lightning faults. To determine the accuracy of this classification, the fault is varied according to the distance and impedance of the disturbance. From the analysis of the simulation results and calculations, based on the wavelet multi resolution analysis method used in fault classifying, the average value of the approximation coefficient used to classify the type of fault is obtained. Based on the results of the study, it can be said that all types of fault analyzed in this study have met the classification requirements using the wavelet multi resolution analysis method
Artificial Neural Network Application for Thermal Image Based Condition Monitoring of Zinc Oxide Surge Arresters Novizon Novizon; Zulkurnain Abdul-Malek; Aulia Aulia
Indonesian Journal of Electrical Engineering and Computer Science Vol 7, No 3: September 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v7.i3.pp593-605

Abstract

Manual analysis of thermal image for detecting defects and classifying of condition of surge arrester take a long time. Artificial neural network is good tool for predict and classify data. This study applied neural network for classify the degree of degradation of surge arrester. Thermal image as input of neural network was segmented using Otsu’s segmentation and histogram method to get features of thermal image. Leakage current as a target of supervise neural network was extracted and applied Fast Fourier Transform to get third harmonic of resistive leakage current. The classification results meet satisfaction with error about 3%.
Studi Kelayakan Sistem Pentanahan pada Gedung Teknik Elektro Universitas Andalas Yudia Meka Seftiani; Novizon Novizon
Elektron : Jurnal Ilmiah Volume 14 Nomor 2 Tahun 2022
Publisher : Teknik Elektro Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30630/eji.14.2.297

Abstract

The grounding system is one part of the electric power system that has an important role in flowing overcurrent from the electric power system to the ground due to electrical power system disturbances or lightning strikes that can endanger the building and its surroundings. This grounding system aims to protect humans, electrical equipment, and electrical installations from the danger of electrical short circuits. In compliance with official regulations, safety standards and according to general electrical installation regulatory standards (PUIL) to avoid the danger of lightning strikes in buildings, it is necessary to have grounding resistance value of less than five ohms and is made as small as possible. In this study, the measurement of grounding resistance seen from the depth of the grounding and the grounding resistance are arranged in parallel. The results of this study indicate that the parallel grounding resistance method produces a more significant reduction in the value of grounding resistance compared to the grounding resistance in a certain depth From the calculation results, the resistance value of the Electrical Engineering Building at Andalas University using a rod electrode with a diameter of 0.016 meters is 24.5 Ω with an electrode depth of 0.5 meters and at a depth of 1 meter a grounding value of 17.52 Ω is obtained. The deeper the depth of the electrode, the smaller the resulting resistance value, and installing a grounding system with the multirod method, namely arranging electrodes in parallel with a certain depth, obtains less resistance compared to not parallelizing the electrodes
Perencanaan Pengembangan Sistem Informasi Perpustakaan Untuk Taman Bacaan Masyarakat (TBM) Karang Putih Heru Dibyo Laksono; Amirul Luthfi; Reri Afrianita; Novizon Novizon; Astri Astia Ningsih
Jurnal Andalas: Rekayasa dan Penerapan Teknologi Vol. 2 No. 2 (2022): Desember 2022
Publisher : Jurusan Teknik Elektro, Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jarpet.v2i2.34

Abstract

Kegiatan perencanaan pengembangan sistem informasi untuk pengelolaan  Taman Bacaan Masyarakat (TBM) Karang Putih dengan mitra kegiatan ini adalah Taman Bacaan Masyarakat (TBM) Karang Putih. Permasalahan utama dari TBM  dimana belum memiliki sistem pengelolaan  yang berbasis teknologi informasi untuk mendukung aktifitas kegiatan sehari–hari. Untuk itu dilakukan pengembangan aplikasi yang berbasis teknologi informasi untuk pengelolaan aktivitas di TBM Karang Putih. Pengembangan aplikasi sistem yang berbasis teknologi informasi ini bertujuan untuk pengelolaan aktivitas di TBM Karang Putih secara efektif dan efisien. Adapun manfaat dari adanya aplikasi sistem informasi ini selain untuk membantu pengelolaan aktivitas sehari – hari di Taman Bacaan Masyarakat (TBM) Karang Putih  juga mampu memberikan dampak pada peningkatan proses pembelajaran, peningkatan  kesadaran dan kemampuan penggunaan teknologi informasi di Taman Bacaan Masyarakat (TBM) Karang Putih Kelurahan Batu Gadang Kecamatan Lubuk Kilangan Kota Padang. Adapun metoda pelaksanaan kegiatan ini akan difokuskan pada perencanaan pengembangan aplikasi sistem informasi untuk membantu pengelolaan aktivitas di Taman Bacaan Masyarakat (TBM) Karang Putih.
Analisa Sistem Load Frequency Control dengan Metoda Linear Quadratic Gaussian (LQG) dan Linear Quadratic Gaussian-Loop Transfer Recovery (LQG-LTR) Heru Dibyo Laksono; Novizon; Anisa Widi Adriana
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.25908

Abstract

Artikel ini mendeskripsikan perancangan dan analisa sistem Load Frequency Control (LFC) tipe non reheat tanpa dan dengan metoda Linear Quadractic Gaussian (LQG) dan metoda Linear Quadratic Gaussian – Loop Transfer Recovery (LQG – LTR). Sistem Load Frequency Control (LFC) tipe non reheat dinyatakan dalam bentuk persamaan keadaan. Pengendali dirancang dengan metoda LQG dan metoda LQG – LTR dengan bantuan perangkat lunak Matlab serta berdasarkan kriteria perancangan tertentu. Analisa yang dilakukan meliputi analisa tanggapan peralihan, analisa tanggapan domain frekuensi untuk fungsi alih lingkar terbuka, analisa tanggapan domain frekuensi untuk fungsi alih lingkar tertutup dan analisa kekokohan. Untuk analisa tanggapan peralihan, parameter yang diamati waktu naik, waktu puncak, waktu keadaan mantap dan nilai lewatan maksimum. Untuk analisa tanggapan domain frekuensi untuk fungsi alih lingkar terbuka, parameter yang diamati adalah margin penguatan. Untuk analisa tanggapan domain frekuensi untuk fungsi alih lingkar tertutup, parameter yang diamati adalah lebar pita. Untuk analisa kekokohan, parameter yang diamati adalah nilai puncak sensitivitas dan nilai puncak sensitivitas komplementer. Hasil perancangan memeperlihatkan bahwa dengan pengendali LQG – LTR, sistem Load Frequency Control (LFC) memenuhi kriteria perancangan. Adapun nilai parameter yang diperoleh dari tanggapan peralihan meliputi waktu naik sebesar 0.1002 detik, waktu puncak sebesar 0.5086 detik, waktu keadaan mantap sebesar 1.6343 detik dan nilai lewatan maksimum sebesar 17.9010 %. Nilai parameter yang diperoleh dari tanggapan domain frekuensi untuk fungsi alih lingkar terbuka yaitu margin penguatan sebesar tidak terhingga dan nilai parameter yang diperoleh dari tanggapan domain frkeuensi untuk fungsi alih lingkar tertutup yaitu lebar pita sebesar 19.7040 rad/detik dan nilai parameter yang diperoleh dari analisa kekokohan yaitu nilai puncak sensitivitas sebesar 1.1591 dan nilai puncak sensitivitas komplementer sebesar 0.9160.
Karakteristik Medan Listrik-Dekat Petir Positive Cloud to Ground Yudia Meka Seftiani; Ariadi Hazmi; Novizon Novizon; Akbar Abadi; Riza Widia
Elektron : Jurnal Ilmiah Volume 15 Nomor 1 Tahun 2023
Publisher : Teknik Elektro Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30630/eji.15.1.334

Abstract

This study was conducted on 19 electric field data near positive lightning cloud to ground (+CG). The electric field change of +CG lightning consist of preliminary breakdown (PB) and return stroke (RS). The analysis conducted in this research are: PB/RS ratio, PB-RS separation, pre-return stroke duration, pulse train duration, and individual pulse duration. Furthermore, the relationship between +CG lightning and cloud image satellite was observed the average value of PB/RS ratio, PB-RS separation, prereturn stroke duration, pulse train duration and individual pulse duration were 13,89%, 91,53 ms, 102,23 ms, 1,20 ms,150,31 μs, respectively.
Perencanaan Pengembangan Modul Pembelajaran Matematika Untuk Warga Belajar Paket C Berbasis Open Source (Scilab) di Pusat Kegiatan Belajar Masyarakat (PKBM) Karang Putih Heru Dibyo Laksono; Reri Afrianita; Novizon Novizon
Warta Pengabdian Andalas Vol 30 No 2 (2023)
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jwa.30.2.339-345.2023

Abstract

The planning for the development of a mathematics learning module for residents studying package C based on the open-source platform Scilab at the Community Learning Center (PKBM) Karang Putih is one of the solutions to address the lack of facilities, especially open-source learning media. The activity plan started with discussions and information sharing. In this stage, discussions and experiences were shared regarding the Scilab-based mathematics learning module for package C learners. The second activity is the analysis of the module's needs. Based on the discussion's outcomes, decisions will be made about the type of module to be created, the required features, potential challenges, necessary resources for the development process, and so on. The third activity is the design of the learning module. During this phase, the interface and layout of the open-source Scilab-based mathematics learning module are designed. The final activity is the development of the learning module. This stage involves implementing the outcomes of the analysis and design of the mathematics learning module. It also includes testing to ensure that all functions work as intended. By following this planned process, the development of the mathematics learning module for package C learners using Scilab will be expected to provide a valuable open-source learning resource at the Community Learning Center (PKBM) Karang Putih.