Wireless Sensor Network Based Server Room Temperature Monitoring System Reza Nandika; Era Madona; Laxsmy Devy; Adi Chandranata; Yultrisna Yultrisna
JECCOM: International Journal of Electronics Engineering and Applied Science Vol. 1 No. 1 (2023)
Publisher : Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30642/jeccom.1.1.16-22.2023

Abstract

A remote temperature monitoring system has been created in the server room using LoRa technology which is based on preventing overheating on servers which can affect the performance of components in the server. The research objective is to design and implement a new LoRa-based server room monitoring system design. The targets of this research are (a) creating a system prototype, (b) programming the system with the help of Arduino IDE, (c) measuring system performance. The research method starts from making a prototype and measuring system performance. The results of system performance measurements, testing on LoRa showed the best RSSI results of -56 dBm, temperature data from 17°C -19°C and humidity from 55% to 59% in the server room. Overall the tool can function well.
Application of hart concentrator to save the number of input analogue channel usage in PLC PAC system on SCADA cimplicity Anton Hidayat; Reza Nandika; Anton Anton; Nadia Alfitri; Alfred Trinanda
JECCOM: International Journal of Electronics Engineering and Applied Science Vol. 1 No. 1 (2023)
Publisher : Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30642/jeccom.1.1.23-33.2023

Abstract

The types of inputs and outputs of a control system that exist today are quite varied with their respective advantages and disadvantages that can be adapted to existing needs. So with the complexity of the system, the price is also very expensive. As one option to overcome this problem is to utilize Highway Addressable Remote Transducer (HART) data through the application of the HART Concentrator System (HCS). HART data has four variables, namely Primary Value (PV), Secondary Value (SV), Third Value (TV) and Fourth Value (FV). All this data can be sent simultaneously to HCS and collected. Then the data on the HCS will be sent via RS485 serial communication to the Modbus Gateway TCPIP. At this Modbus TCPIP gateway, Modbus data can be sent via an Ethernet network so that it can be accessed flexibly by SCADA.